Determination of 129I in Fukushima Soil Samples by ICP-MS with an Octopole Reaction System

被引:22
|
作者
Ohno, Takeshi [1 ]
Muramatsu, Yasuyuki [1 ]
Toyama, Chiaki [1 ]
Nakano, Kazumi [2 ]
Kakuta, Shinichiro [2 ]
Matsuzaki, Hiroyuki [3 ]
机构
[1] Gakushuin Univ, Fac Sci, Dept Chem, Toshima Ku, Tokyo 1718588, Japan
[2] Japan Applicat Ctr, Hachioji, Tokyo 1928510, Japan
[3] Univ Tokyo, Sch Engn, Dept Nucl Engn & Management, Bunkyo Ku, Tokyo 1138656, Japan
关键词
NUCLEAR-POWER-PLANT; IODINE; I-131; IBARAKI; UKRAINE; CANCER;
D O I
10.2116/analsci.29.271
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed for the determination of I-129 in soil samples that uses an ICP-MS equipped with an octopole reaction system. Oxygen was used as the reaction gas for reducing the background intensity of m/z 129, principally by Xe-129(+). The contribution of polyatomic ions, such as (IH2)-I-127+, could be effectively corrected for by assuming a production ratio ((IH2)-I-127+/I-127(+) = 3 x 10(-8)). The measured I-129/I-127 ratios in a NIST standard solution and Fukushima soil samples are consistent with the expected value within the analytical error. This method provides a powerful tool for investigating radioiodine contamination in Fukushima and elsewhere.
引用
收藏
页码:271 / 274
页数:4
相关论文
共 50 条
  • [41] Determination of 129I in conifer samples around nuclear facilities in Argentina
    Quintana, EE
    Thyssen, SM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 245 (03) : 545 - 550
  • [42] Microwave-based digestion method for extraction of 127I and 129I from solid material for measurements by AMS and ICP-MS
    Gomez-Guzman, J. M.
    Enamorado-Baez, S. M.
    Pinto-Gomez, A. R.
    Abril-Hernandez, J. M.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 303 (2-3) : 103 - 108
  • [43] Determination of 129I in Conifer Samples Around Nuclear Facilities in Argentina
    E. E. Quintana
    S. M. Thyssen
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 245 : 545 - 550
  • [44] 129I and 129I/127I ratio determination in environmental biological samples by RNAA, AMS and direct γ-X spectrometry measurements
    Fréchou, C
    Calmet, D
    Bouisset, P
    Piccot, D
    Gaudry, A
    Yiou, F
    Raisbeck, G
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 249 (01) : 133 - 138
  • [45] PU and NP analysis of soil and sediment samples with ICP-MS
    Roellin, S.
    Sahli, H.
    Holzer, R.
    Astner, M.
    Burger, M.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (05) : 821 - 827
  • [46] DETERMINATION OF I-129 IN SOIL SAMPLES
    TAKEISHI, M
    KATAGIRI, H
    NOMURA, T
    YAMATO, A
    MIURA, M
    HEALTH PHYSICS, 1984, 46 (06): : 1324 - 1324
  • [47] Determination of boron and lithium in ferroelectric samples by ICP-OES and ICP-MS
    Vuollo, Pekka
    Honkamo, Johanna
    Niemela, Matti
    Peramaki, Paavo
    Jantunen, Heli
    MICROCHIMICA ACTA, 2009, 164 (1-2) : 217 - 224
  • [48] Determination of boron and lithium in ferroelectric samples by ICP-OES and ICP-MS
    Pekka Vuollo
    Johanna Honkamo
    Matti Niemelä
    Paavo Perämäki
    Heli Jantunen
    Microchimica Acta, 2009, 164 : 217 - 224
  • [49] Determination of lead isotopes ratio in rock samples by ICP-MS
    Zheng, Pei-Xi
    Zhou, Yan
    Wang, Tie-Fu
    Liu, Li
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A1522 - A1522
  • [50] Determination of U isotopic ratios in environmental samples by ICP-MS
    Uchida, S
    García-Tenorio, R
    Tagami, K
    García-León, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (07) : 889 - 892