The influence of the concealed pollution sources upon the indoor air quality in houses

被引:0
|
作者
Hayashi, M [1 ]
Osawa, H [1 ]
机构
[1] Miyagigakuin Womens Univ, Dept Living & Cultural Sci, Sendai, Miyagi 9818557, Japan
关键词
VOC; exhaust ventilation system; beam space; air tightness; multi tracer gas;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is necessary to consider the influence of the pollution sources in the concealed spaces as well as to control emission rate from the interior materials for better IAQ. In this study the influences of the concealed pollution sources were investigated. When the ventilation system was changed from the air supply type to the air exhaust type, the concentration of formaldehyde increased. The infiltration ratio from concealed space was almost 100% in the case of the beam spaces and the partitions. The ratio from the crawl space under the first floor and the truss space under the roof were not high. The ratio from the envelope wall was changed with the pressure difference. These results showed that it is necessary to prevent infiltration from the concealed space and to control the emission rate from the concealed pollution sources.
引用
收藏
页码:1957 / 1962
页数:6
相关论文
共 50 条
  • [41] Sources of Indoor Air Pollution and Respiratory Health in Preschool Children
    Fuentes-Leonarte, Virginia
    Ballester, Ferran
    Maria Tenias, Jose
    JOURNAL OF ENVIRONMENTAL AND PUBLIC HEALTH, 2009, 2009
  • [42] Contribution Of Lighting Sources To Indoor Air Pollution In Rural Uganda
    Muyanja, D.
    Allen, J. G.
    Vallarino, J.
    Kakuhikire, B.
    Christiania, D. C.
    Tsai, A. C.
    Lai, P. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [43] Influence of terpenes on indoor air quality
    Pytel, Klaudia
    Marcinkowska, Renata
    Zabiegala, Bozena
    PROCEEDINGS OF THE 14TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2018, : 246 - 252
  • [44] The air within: reviewing the sources and health effects of indoor air pollution in households
    Singh, Oinam Mangalsana
    Devi, Kangabam Kripaliya
    Khoiyangbam, Raju Singh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2024,
  • [45] The effect of external atmospheric pollution on indoor air quality
    Kukadia, V
    Palmer, J
    17TH AIVC CONFERENCE - OPTIMUM VENTILATION AND AIR FLOW CONTROL IN BUILDING, PROCEEDINGS, VOLS 1 AND 2, 1996, : 41 - 53
  • [46] The impact of renovation on the air quality in the stadium, and prevention of indoor air pollution
    Jiang, Shujun
    Cai, Wenfei
    Luo, Cheng
    Zhang, Fengyan
    ENVIRONMENTAL RESEARCH, 2024, 257
  • [47] Measurement and evaluation of indoor air quality by passive method in Korean houses
    Kim, H
    Tabuchi, S
    Tanabe, S
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 712 - 717
  • [48] SOURCES OF INDOOR RADON IN HOUSES - A REVIEW
    BRUNO, RC
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1983, 33 (02): : 105 - 109
  • [49] INDOOR AIR QUALITY MEASUREMENTS IN ENERGY-EFFICIENT HOUSES.
    Berk, James V.
    Hollowell, Craig D.
    Lin, Chin-I
    Proceedings, Annual Meeting - Air Pollution Control Association, 1979, 2
  • [50] Field survey of indoor air quality in detached houses in Niigata Prefecture
    Sakaguchi, J
    Akabayashi, S
    INDOOR AIR, 2003, 13 : 42 - 49