Comparison of normal phase operation and phase reversal studies in a pulsed sieve plate extraction column

被引:23
|
作者
Lade, Vikesh Gurudas [1 ]
Rathod, Virendra Kisan [1 ]
Bhattacharyya, Saurau [2 ]
Manohar, Smitha [2 ]
Wattal, Piaray Kishen [2 ]
机构
[1] Inst Chem Technol, Dept Chem Engn, Mumbai 400019, Maharashtra, India
[2] BARC Trombay, BETDD, Mumbai 400085, Maharashtra, India
来源
关键词
Pulsed sieve plate extraction column (PSPEC); Phase reversal; Holdup; Drop size; Flooding; Duty cycle; LIQUID-LIQUID-EXTRACTION; MASS-TRANSFER; DROP SIZE; INVERSION; HOLDUP; DISPERSION; PREDICTION; EFFICIENCY;
D O I
10.1016/j.cherd.2012.11.005
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The hydrodynamic characteristics of a pulsed sieve plate extraction column (PSPEC) was studied experimentally using two different liquid phase systems, namely water/kerosene and 30%TBP (tributyl phosphate) in NPH (normal paraffin hydrocarbon)/0.3 M HNO3. The aqueous phase as the dispersed phase and the organic phase as the continuous phase (phase reversal) and vice versa (normal phase operation) studies in a pulsed sieve plate extraction column 0.076 m in diameter and 1 m height are presented in this paper. The hydrodynamic properties like drop size and holdup are characterized as a function of various operating parameters namely pulse velocity, dispersed phase and continuous phase velocity and duty cycle of pulsing. Flooding in the column was, also investigated for the changes involving flow ratio of continuous phase to that of the dispersed phase for both insufficient and excessive pulsing. It has been observed that phase reversal mode of operation is not efficient as compared to normal phase operation for the PSPEC. (C) 2012 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1133 / 1144
页数:12
相关论文
共 50 条
  • [31] EXPERIMENTAL-STUDY OF DROPLET DISPERSION IN A PULSED SIEVE PLATE EXTRACTION COLUMN
    HAVERLAND, H
    VOGELPOHL, A
    CHEMIE INGENIEUR TECHNIK, 1988, 60 (06) : 494 - 495
  • [32] Mass Transfer Characteristics in a Standard Pulsed Sieve-Plate Extraction Column
    Jiao Caishan
    Ma Shuai
    Song Qiong
    3RD INTERNATIONAL CONFERENCE ON ASIAN NUCLEAR PROSPECTS (ANUP2012), 2013, 39 : 348 - 357
  • [33] SINGLE-PHASE AXIAL MIXING STUDIES IN PULSED SIEVE-PLATE LIQUID-LIQUID-EXTRACTION COLUMNS
    INGHAM, J
    SLATER, MJ
    RETAMALES, J
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1995, 73 (A5): : 492 - 496
  • [34] RECOVERY AND SEPARATION OF COBALT AND NICKEL IN A PULSED SIEVE-PLATE EXTRACTION COLUMN
    GOLDING, JA
    LEE, J
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1981, 20 (02): : 256 - 261
  • [35] Axial dispersion, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column by radiotracer residence time distribution analysis
    Din, Ghiyas Ud
    Chughtai, Imran Rafiq
    Inayat, Mansoor Hameed
    Khan, Iqbal Hussain
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) : 1818 - 1824
  • [36] Modeling of a two-phase countercurrent pulsed sieve plate extraction column-A hybrid CFD and radiotracer RTD analysis approach
    Din, Ghiyas Ud
    Chughtai, Imran Rafiq
    Inayat, Mansoor Hameed
    Khan, Iqbal Hussain
    Qazi, Nasrullah Khan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2010, 73 (02) : 302 - 309
  • [37] CONTINUOUS PHASE AXIAL MIXING IN PULSED SIEVE PLATE LIQUID-LIQUID-EXTRACTION COLUMNS
    GODFREY, JC
    HOULTON, DA
    MARLEY, ST
    MARROCCHELLI, A
    SLATER, MJ
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1988, 66 (05): : 445 - 457
  • [38] Investigation of flow dynamics of single phase in a pulsed sieve-plate column using radiotracer technique
    Sunil Goswami
    Nirvik Sen
    J. S. Samantray
    A. Dash
    V. K. Sharma
    K. T. Sheony
    H. J. Pant
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 313 : 669 - 676
  • [39] Investigation of flow dynamics of single phase in a pulsed sieve-plate column using radiotracer technique
    Goswami, Sunil
    Sen, Nirvik
    Samantray, J. S.
    Dash, A.
    Sharma, V. K.
    Sheony, K. T.
    Pant, H. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 313 (03) : 669 - 676
  • [40] STUDIES ON A PULSATING SIEVE PLATE EXTRACTION COLUMN UNDER EXTREME CONDITIONS
    RAUSCHER, H
    BLASS, E
    CHEMIE INGENIEUR TECHNIK, 1991, 63 (02) : 150 - 151