Comparison of normal phase operation and phase reversal studies in a pulsed sieve plate extraction column

被引:23
|
作者
Lade, Vikesh Gurudas [1 ]
Rathod, Virendra Kisan [1 ]
Bhattacharyya, Saurau [2 ]
Manohar, Smitha [2 ]
Wattal, Piaray Kishen [2 ]
机构
[1] Inst Chem Technol, Dept Chem Engn, Mumbai 400019, Maharashtra, India
[2] BARC Trombay, BETDD, Mumbai 400085, Maharashtra, India
来源
关键词
Pulsed sieve plate extraction column (PSPEC); Phase reversal; Holdup; Drop size; Flooding; Duty cycle; LIQUID-LIQUID-EXTRACTION; MASS-TRANSFER; DROP SIZE; INVERSION; HOLDUP; DISPERSION; PREDICTION; EFFICIENCY;
D O I
10.1016/j.cherd.2012.11.005
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The hydrodynamic characteristics of a pulsed sieve plate extraction column (PSPEC) was studied experimentally using two different liquid phase systems, namely water/kerosene and 30%TBP (tributyl phosphate) in NPH (normal paraffin hydrocarbon)/0.3 M HNO3. The aqueous phase as the dispersed phase and the organic phase as the continuous phase (phase reversal) and vice versa (normal phase operation) studies in a pulsed sieve plate extraction column 0.076 m in diameter and 1 m height are presented in this paper. The hydrodynamic properties like drop size and holdup are characterized as a function of various operating parameters namely pulse velocity, dispersed phase and continuous phase velocity and duty cycle of pulsing. Flooding in the column was, also investigated for the changes involving flow ratio of continuous phase to that of the dispersed phase for both insufficient and excessive pulsing. It has been observed that phase reversal mode of operation is not efficient as compared to normal phase operation for the PSPEC. (C) 2012 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1133 / 1144
页数:12
相关论文
共 50 条
  • [1] Two-phase flow characteristics in a pulsed-sieve-plate extraction column
    Dai, Youyuan
    Lei, Xia
    Zhu, Shenlin
    Wang, Jiading
    Journal of Chemical Industry and Engineering (China) (English Edition), 1988, 39 (04): : 422 - 430
  • [2] Comparison of the performance of a pulsed disc and doughnut column with a pulsed sieve plate liquid extraction column
    Jahya, AB
    Pratt, HRC
    Stevens, GW
    SOLVENT EXTRACTION AND ION EXCHANGE, 2005, 23 (03) : 307 - 317
  • [3] Hydrodynamics of a Pulsed Sieve Plate Extraction Column
    Somkuwar, Nitin
    Kolhe, Nitin
    Rathod, Virendra
    INDIAN CHEMICAL ENGINEER, 2014, 56 (03) : 235 - 257
  • [4] HOLDUP STUDIES IN A PULSED SIEVE-PLATE SOLVENT EXTRACTION COLUMN
    SEHMEL, GA
    BABB, AL
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1963, 2 (01): : 38 - &
  • [5] Radiotracer investigations to study the hydrodynamic characteristics of continuous phase in a pulsed sieve plate extraction column
    Din, G. U.
    Khan, I. H.
    Chughtai, I. R.
    Inayat, M. H.
    Jin, J. H.
    TRACER 6 - THE 6TH INTERNATIONAL CONFERENCE ON TRACERS AND TRACING METHODS, 2013, 50
  • [6] CFD and experimental studies of single phase axial dispersion coefficient in pulsed sieve plate column
    Kolhe, N. S.
    Mirage, Y. H.
    Patwardhan, A. V.
    Rathod, V. K.
    Pandey, N. K.
    Mudali, U. Kamachi
    Natarajan, R.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (10A): : 1909 - 1918
  • [7] Mass transfer in pulsed sieve plate extraction column
    Qian, Yu
    Fei, Weiyang
    Wang, Jiading
    Journal of Chemical Industry and Engineering (China) (English Edition), 1988, 39 (05): : 522 - 529
  • [8] Dispersed Phase Holdup in a Tall and Low Plate Free Area Liquid Pulsed Sieve-Plate Extraction Column
    Khawaja, S. Y.
    Usman, M. R.
    Khan, S.
    Afzal, W.
    Akhtar, N. A.
    SEPARATION SCIENCE AND TECHNOLOGY, 2013, 48 (01) : 175 - 182
  • [9] CFD simulations to predict dispersed phase holdup in a pulsed sieve plate column
    Sen, Nirvik
    Singh, K. K.
    Patwardhan, A. W.
    Mukhopadhyay, S.
    Shenoy, K. T.
    SEPARATION SCIENCE AND TECHNOLOGY, 2018, 53 (16) : 2587 - 2600
  • [10] Two-phase flow characteristics in a coalescence-Dispersion pulsed-sieve-plate extraction column
    Tang, XJ
    Luo, GS
    Li, HB
    Wang, JD
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2004, 12 (01) : 1 - 6