Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate

被引:8
|
作者
Bird, Nicholas J. [1 ]
Peters, Christina [1 ]
Michell, A. Robert [2 ]
Peters, A. Michael [1 ]
机构
[1] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[2] St Bartholomews Med Sch, William Harvey Res Inst, Dept Biochem Pharmacol, London, England
关键词
Cr-51-ethylenediaminetetraacetic acid; glomerular filtration rate; iohexol; single sample; validation;
D O I
10.1097/MNM.0b013e328310b378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim To develop a strategy for checking the reliability of slope intercept measurement of glomerular filtration rate (GFR). Methods Six blood samples, obtained bilaterally 20-240 min after the injection of Cr-51-ethylenediaminetetraacetic acid (EDTA) and iohexol into opposite arms, were assayed for indicator injected contralaterally. GFR6(iohexol), the reference value, was measured for all six samples and GFR3(EDTA) (slope-intercept) for the last three samples (per 1.73 m(2)). GFR was measured from the half-time [GFR/extracellular fluid volume (ECV)3(EDTA)], for the single samples at 2-4h (Christensen-Groth; GFR1) and for creatinine [estimated GFR (eGFR)]. Results In six of the 97 studies, the correlation coefficient W of the fit to the last three sample points was less than 0.99. In the remaining 91 studies, GFR3(EDTA) disagreed with GFR/ECVEDTA by more than 15% in 19 studies (group A) and by less than 15% in 72 studies (group 13). GFR3(EDTA) disagreed with GFR6(iohexol) by 12.6% in group A but only by 6.3% in group B (P < 0.001). No such discrimination was displayed by eGFR. Although GFR3(EDTA) was within 15% of GFR6(iohexol) in 14 group A studies, eGFR was within 15% of GFR3(EDTA) in only eight studies and disagreed by more than 15% in six studies. Conversely, in the five of the 19 studies in which GFR3(EDTA) disagreed with GFR6(iohexol) by more than 15%, the agreement between eGFR and GFR3(EDTA) Was less than 15% in two studies and more than 15% in three studies. GFR3(EDTA) was within 15% of GFR/ECV3(EDTA) in all six studies in which r was less than 0.99, and GFR3(EDTA) disagreed with GFR6(iohexol) by less than 15%. Confidence in GFR3(EDTA) was not improved by GFR1 or eGFR. Conclusion Slope intercept GFR is reliable if within 15% of GFR/ECV3. Estimated GFR was ineffective as a second checkpoint. GFR1 did not help when the fit was poor. Nucl Med Commun 29:1086-1092 (c) 2008 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1086 / 1092
页数:7
相关论文
共 50 条
  • [31] Measurement of Glomerular Filtration Rate in Patients Undergoing Renal Surgery for Cancer: Estimated Glomerular Filtration Rate versus Measured Glomerular Filtration Rate in the Era of Precision Medicine
    Trevisani, Francesco
    Simeoni, Mariadelina
    Bettiga, Arianna
    Cinque, Alessandra
    Floris, Matteo
    KIDNEY & BLOOD PRESSURE RESEARCH, 2024, 49 (01): : 336 - 344
  • [32] A comparison of four-sample slope-intercept and single-sample 51Cr-EDTA glomerular filtration rate measurements
    Porter, Charlotte A.
    Bradley, Kevin M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (05) : 465 - 468
  • [33] The new BNMS guidelines for glomerular filtration rate measurement of glomerular filtration rate
    Fleming, JS
    Nunan, TO
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (08) : 755 - 757
  • [34] Re-evaluation of the new Jodal-Brochner-Mortensen equation for one-pool correction of slope-intercept measurement of glomerular filtration rate
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (05) : 375 - 380
  • [35] Measured and estimated glomerular filtration rate
    Hebert, Lee A.
    Nori, Uday
    Hebert, Paul L.
    NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (10): : 1068 - 1068
  • [36] Microalbuminuria and estimated glomerular filtration rate
    Veriava, Y.
    SOUTH AFRICAN FAMILY PRACTICE, 2012, 54 (02) : S17 - S19
  • [37] Measurement of Glomerular Filtration Rate
    Mulhern, Jeffrey G.
    Perrone, Ronald D.
    SEMINARS IN NUCLEAR MEDICINE, 2022, 52 (04) : 453 - 466
  • [38] Measurement of glomerular filtration rate
    Gaspari, F
    PerIco, N
    Remuzzi, G
    KIDNEY INTERNATIONAL, 1997, : S151 - S154
  • [39] An investigation into the accuracy of using serum creatinine estimated glomerular filtration rate to predict measured glomerular filtration rate
    Hutton, Lawrence G.
    Porter, Charlotte A.
    Morgan, Andrew J.
    Bradley, Kevin M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (04) : 349 - 352
  • [40] Prediction of Glomerular Filtration Rate in Cancer Patients by an Equation for Japanese Estimated Glomerular Filtration Rate
    Funakoshi, Yohei
    Fujiwara, Yutaka
    Kiyota, Naomi
    Mukohara, Toru
    Shimada, Takanobu
    Toyoda, Masanori
    Imamura, Yoshinori
    Chayahara, Naoko
    Umezu, Michio
    Otsuki, Naoki
    Nibu, Ken-ichi
    Minami, Hironobu
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2013, 43 (03) : 271 - 277