Tank-tests of a Prototype Electromagnetic Groundwater Flowmeter

被引:0
|
作者
Hayes, Michael [1 ]
Ben Mitchell [1 ]
Bonnett, Blair [1 ]
Frampton, Michael [1 ]
Heffernan, Bill [1 ]
机构
[1] Univ Canterbury, Dept Elect & Comp Engn, Christchurch, New Zealand
关键词
flowmeters; electromagnetic; electrode noise; 1/f noise; water resources;
D O I
10.1109/i2mtc.2019.8827068
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nutrients leaching through groundwater are one contributor to waterway contamination. Guiding land use decisions to reduce the impact on water resources requires accurate knowledge of the flow of groundwater. Currently, measurements from monitored wells are used to tune models of this flow. However, there are few wells available and so the data is sparse. An electromagnetic flowmeter has been proposed to simplify the measurement of groundwater flow and provide data to generate more robust models. Although based on a sensing technique that has been widely used for measurement of flow in pipes, the slow movement of groundwater results in small signals subject to significant interference. This paper presents some initial laboratory results from a prototype electromagnetic flowmeter showing that there is a tradeoff between noise and self-interference reduction.
引用
收藏
页码:618 / 623
页数:6
相关论文
共 50 条
  • [31] Optimizing electromagnetic flowmeter coils
    Vel't, ID
    Mushkin, AM
    Sychev, GI
    MEASUREMENT TECHNIQUES, 2003, 46 (02) : 209 - 211
  • [32] A TRANSISTORIZED ELECTROMAGNETIC BLOOD FLOWMETER
    RICHARDSON, A
    CISZCZON, WJ
    COOPER, T
    JOURNAL OF APPLIED PHYSIOLOGY, 1961, 16 (05) : 940 - &
  • [33] AN ELECTROMAGNETIC CATHETER-FLOWMETER
    KOLIN, A
    ARCHER, JD
    ROSS, G
    CIRCULATION RESEARCH, 1967, 21 (06) : 889 - &
  • [34] LABORATORY INVESTIGATION AND ANALYSIS OF A GROUNDWATER FLOWMETER
    MELVILLE, JG
    MOLZ, FJ
    GUVEN, O
    GROUND WATER, 1985, 23 (04) : 486 - 495
  • [35] The Experiment Study on Tank Capacity Measurement with Flowmeter
    Wang, Qiming
    Sun, Bin
    Zhao, Weiguo
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1105 - 1108
  • [36] ULTRASONIC FLOWMETER TESTS WITH SLURRIES
    COLWELL, JM
    SHOOK, CA
    GILLIES, RG
    SMALL, M
    JOURNAL OF PIPELINES, 1988, 7 (02): : 127 - 140
  • [37] NEW FLOWMETER PASSES TESTS
    DANEKER, JR
    KONTOR, JS
    WATER & WASTES ENGINEERING, 1975, 12 (04): : 58 - &
  • [38] EVALUATING DESIGN OF A PROTOTYPE LINEAR RESISTANCE FLOWMETER
    LORENZI, A
    CONTROL AND INSTRUMENTATION, 1975, 7 (09): : 24 - 27
  • [39] FMIT PROTOTYPE LINAC TANK
    COOPS, WJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 2991 - 2993
  • [40] FMIT PROTOTYPE LINAC TANK
    COOPS, W
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 143 - 143