Anxiety and depression as risk factors for ICD shocks and mortality in patients with an implantable cardioverter defibrillator - A systematic review

被引:11
|
作者
Lindekilde, Nanna [1 ]
Skov, Ole [1 ]
Skovbakke, Soren J. [1 ]
Johansen, Jens B. [2 ]
Nielsen, Jens C. [3 ,4 ]
Pedersen, Susanne S. [1 ,2 ]
机构
[1] Univ Southern Denmark, Dept Psychol, Campusvej 55, DK-5230 Odense M, Denmark
[2] Odense Univ Hosp, Dept Cardiol, J B Winsl ows Vej 4, DK-5000 Odense C, Denmark
[3] Aarhus Univ Hosp, Dept Cardiol, DK-8200 Aarhus, Denmark
[4] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Blvd 82, DK-8200 Aarhus N, Denmark
关键词
Anxiety; Depression; Shocks; Mortality; Implantable cardioverter defibrillator; Systematic review; QUALITY-OF-LIFE; FOLLOW-UP DATA; VENTRICULAR-ARRHYTHMIAS; CARDIOVASCULAR-DISEASE; POSTTRAUMATIC STRESS; PREVENTION; DISTRESS; RECIPIENTS; SYMPTOMS; OUTCOMES;
D O I
10.1016/j.genhosppsych.2022.07.008
中图分类号
R749 [精神病学];
学科分类号
100205 ;
摘要
Objective: To examine associations between baseline anxiety and depression and occurrence of ICD shocks and risk of mortality in patients with an implantable cardioverter defibrillator (ICD). Method: We systematically searched EMBASE, PubMed, PsycINFO, and CINAHL for eligible studies fulfilling the predefined criteria. Results: We included 37 studies based on 25 different cohorts following 35,003 participants for up to seven years. We observed no association between baseline anxiety nor depression and the occurrence of ICD shocks. More than half of the identified studies (respectively 56% and 60%) indicated a significant association between baseline anxiety or depression and increased risk of mortality (anxiety: n = 5, ranging from Hazard ratios (HR):1.02 [Confidence intervals (CI) 95% 1.00-1.03] to HR:3.45 [CI 95% 1.57-7.60]; depression: n = 6, ranging from HR:1.03 [CI 95% 1.00-1.06] to HR:2.10 [CI 95% 1.44-3.05]). We found a significant association between high methodological quality of the primary study and the detection of a significant association (p < 0.01). Conclusions: Baseline anxiety and depression are associated with increased risk of mortality in patients with an ICD, but not with occurrence of ICD shocks. Inclusion of baseline anxiety and depression in risk stratification of mortality may be warranted.
引用
收藏
页码:96 / 107
页数:12
相关论文
共 50 条
  • [31] The prevalence of depression in patients living with implantable cardioverter defibrillator: a systematic review and meta-analysis
    Oshvandi, Khodayar
    Khatiban, Mahnaz
    Ghanei Gheshlagh, Reza
    Razavi, Mohammadreza
    IRISH JOURNAL OF MEDICAL SCIENCE, 2020, 189 (04) : 1243 - 1252
  • [32] The prevalence of depression in patients living with implantable cardioverter defibrillator: a systematic review and meta-analysis
    Khodayar Oshvandi
    Mahnaz Khatiban
    Reza Ghanei Gheshlagh
    Mohammadreza Razavi
    Irish Journal of Medical Science (1971 -), 2020, 189 : 1243 - 1252
  • [33] Shocks, personality, and anxiety in patients with an implantable defibrillator
    Van Den Broek, Krista C.
    Nyklicek, Ivan
    Van Der Voort, Pepijn H.
    Alings, Marco
    Denollet, Johan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (07): : 850 - 857
  • [34] Anxiety and depression among the patients with frequent implantable cardioverter-defibrillator discharges
    Maryniak, Agnieszka
    Szumowski, Lukasz
    Orczykowski, Michal
    Przybylski, Andrzej
    Walczak, Franciszek
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 132 (02) : E80 - E81
  • [35] Undertreatment of anxiety and depression in patients with an implantable cardioverter defibrillator: Impact on health status
    Hoogwegt, M. T. Madelein
    Kupper, N.
    Theuns, D. A. M. J.
    Zijlstra, W. P.
    Jordaens, L.
    Pedersen, S. S.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2012, 11 : S55 - S55
  • [36] Anxiety disorders with implanted cardioverter defibrillator (ICD) patients
    Benninghoven, D
    Kunzendorf, S
    Heberlein, I
    Jantschek, G
    PSYCHOTHERAPEUT, 2006, 51 (03): : 206 - 213
  • [37] PATIENTS' EXPERIENCE OF REMOTE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) INTERROGATION
    Groarke, J.
    Beirne, A.
    Buckley, U.
    Sugrue, D.
    Keelan, T.
    Galvin, J.
    O'Neill, J.
    Mahon, N.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S408 - S408
  • [38] Anxiety, depression and cardiac anxiety in patients with implantable cardioverter-defibrillator according to gender and age
    Ignacio, Isabelle Brigliadori
    Fernandes, Paolla Algarte
    de Oliveira Maier, Suellen Rodrigues
    Marost Dessotte, Carina Aparecida
    REV RENE, 2021, 22
  • [39] Early statin therapy reduces risk of ICD shocks in patients with an implantable cardioverter-defibrillator undergoing ablation for ventricular tachycardia
    Bunch, T. J.
    Friedman, Paul A.
    Gersh, Bernard J.
    Asirvatham, Samuel J.
    Brady, Peter A.
    Chia, Yong-Mei
    Jahangir, Arshad
    Hammill, Stephen C.
    Monahan, Kristi
    Munger, Thomas M.
    Rea, Robert F.
    Shen, Win K.
    Tabatabaei, Niloufar
    Packer, Douglas L.
    CIRCULATION, 2007, 116 (16) : 320 - 320
  • [40] Predictors of panic for patients with implantable cardioverter-defibrillator (ICD)
    Lang, S.
    Becker, R.
    Herzog, W.
    Hartmann, M.
    Loewe, B.
    PSYCHOTHERAPIE PSYCHOSOMATIK MEDIZINISCHE PSYCHOLOGIE, 2008, 58 (02) : 95 - 95