The consideration of compliance of structural joints in calculation of large panel buildings

被引:3
|
作者
Malakhova, Anna [1 ]
Davletbaeva, Daria [1 ]
机构
[1] Moscow State Univ Civil Engn, Yaroslavskoe Shosse 26, Moscow 129337, Russia
关键词
D O I
10.1051/e3sconf/20199704010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The article presents and analyzes the design solutions of horizontal and vertical joints, as well as methods for determining the coefficient of compliance joints. It also presents the numerical determination of the coefficients of compliance of the horizontal mortar joint in accordance with the standards for the design of large-panel buildings. It is shown that the compliance of the joint on the embedded parts consists of the compliance of the connecting element, embedded parts of the wall panels, namely the metal plate and reinforcing bars of the anchors, as well as the compliance of the welds. In this case, the joint operates in a complex stress-strain state. It is noted that the most difficult is to determine the compliance of embedded parts. Three calculation methods have been developed for the numerical determination of the compliance coefficients of anchor bars under the action of tension (compression), bending moment and shear forces on the embedded part. The deformation of the welds was defined in MGSU in the framework of the experimental research of the work of the vertical seam with embedded parts. The article presents a graph of the deformation in the weld on the applied vertical load on the test piece.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] CONSIDERATION OF LARGE NONHOMOGENEOUS REGIONS FOR CALCULATION OF ELECTRON DOSE DISTRIBUTIONS
    FEHRENTZ, D
    LIEBIG, B
    SCHRODERBABO, P
    STRAHLENTHERAPIE, 1976, 151 (05) : 423 - 442
  • [42] Research on compliance coefficient calculation for heterogeneity material bolted joints of reactor internal
    Institution of Process Equipment and Control Engineering, Zhejiang University of Technology, Hangzhou 310032, China
    Hedongli Gongcheng, 2009, 1 (104-108):
  • [43] STRUCTURAL SYMMETRY CONSIDERATION IN CALCULATION OF UNPERTURBED DIMENSIONS OF POLYMER CHAINS
    NAGAI, K
    JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (02): : 516 - &
  • [44] Load-Carrying Capacity and Rigidity of Horizontal Joints in Prefabricated Panel Buildings.
    Cerny, Jiri
    Stavebnicky Casopis, 1979, 27 (02): : 83 - 97
  • [45] Resistance property and ventilation rate calculation of buildings with large openings
    Gong Guangcai
    Bai Yu
    Li Hongxiang
    Han Bing
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 2107 - 2112
  • [46] Comparison of different calculation methods for structural stresses at welded joints
    Doerk, O
    Fricke, W
    Weissenborn, C
    INTERNATIONAL JOURNAL OF FATIGUE, 2003, 25 (05) : 359 - 369
  • [47] FULL-SIZE TESTS ON LARGE PANEL SYSTEM BUILDINGS.
    Anon
    Concrete plant and production, 1986, 4 (03):
  • [48] STRUCTURAL IMPLICATIONS OF INCREASED PANEL USE IN WOOD-FRAME BUILDINGS
    MORSEFORTIER, LJ
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (06): : 995 - 1003
  • [49] THE DESIGN OF STRUCTURAL-STEEL FRAMES UNDER CONSIDERATION OF THE NONLINEAR BEHAVIOR OF JOINTS
    TSCHEMMERNEGG, F
    HUMER, C
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1988, 11 (02) : 73 - 103
  • [50] Optimization and cost analysis of thickness of vacuum insulation panel for structural insulating panel buildings in cold climates
    Geng, Yichao
    Han, Xu
    Zhang, Hua
    Shi, Luyang
    Journal of Building Engineering, 2021, 33