Scintillator Pixel Detectors for Measurement of Compton Scattering

被引:11
|
作者
Makek, Mihael [1 ]
Bosnar, Damir [1 ]
Pavelic, Luka [1 ,2 ]
机构
[1] Univ Zagreb, Fac Sci, Dept Phys, Bijenicka C 32, Zagreb 10000, Croatia
[2] Inst Med Res & Occupat Hlth, Ksaverska Cesta 2, Zagreb 10000, Croatia
来源
CONDENSED MATTER | 2019年 / 4卷 / 01期
关键词
Compton camera; positron emission tomography; Compton scattering; scintillation detector; silicon photomultiplier; medical applications; IN-SILICO; PERFORMANCE;
D O I
10.3390/condmat4010024
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
The Compton scattering of gamma rays is commonly detected using two detector layers, the first for detection of the recoil electron and the second for the scattered gamma. We have assembled detector modules consisting of scintillation pixels, which are able to detect and reconstruct the Compton scattering of gammas with only one readout layer. This substantially reduces the number of electronic channels and opens the possibility to construct cost-efficient Compton scattering detectors for various applications such as medical imaging, environment monitoring, or fundamental research. A module consists of a 4 x 4 matrix of lutetium fine silicate scintillators and is read out by a matching silicon photomultiplier array. Two modules have been tested with a 22Na source in coincidence mode, and the performance in the detection of 511 keV gamma Compton scattering has been evaluated. The results show that Compton events can be clearly distinguished with a mean energy resolution of 12.2% +/- 0.7% in a module and a coincidence time resolution of 0.56 +/- 0.02 ns between the two modules.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [31] Measurement of the energy distribution of bremsstrahlung using Compton scattering
    Bochek, G. L.
    Deiev, O. S.
    Maslov, N. I.
    JOURNAL OF SURFACE INVESTIGATION-X-RAY SYNCHROTRON AND NEUTRON TECHNIQUES, 2012, 6 (02) : 356 - 361
  • [32] MEASUREMENT OF COMPTON-SCATTERING IN PHANTOMS BY GERMANIUM DETECTOR
    ZASADNY, KR
    KORAL, KF
    FLOYD, CE
    JASZCZAK, RJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 642 - 646
  • [33] ELECTRON STATE IN NAF STUDIED BY COMPTON SCATTERING MEASUREMENT
    FUKAMACH.T
    HOSOYA, S
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1970, 29 (03) : 736 - &
  • [34] Measurement of the energy distribution of bremsstrahlung using Compton scattering
    G. L. Bochek
    O. S. Deiev
    N. I. Maslov
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2012, 6 : 356 - 361
  • [35] Flatfielding of hybrid pixel detectors in tender x-ray scattering
    Freychet, Guillaume
    Zhernenkov, Mikhail
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (05):
  • [36] Effect of multiple coulomb scattering on the beam tests of silicon pixel detectors
    Lan-Kun Li
    Ming-Yi Dong
    Ze Gao
    Liang-Cheng-Long Jin
    Shu-Jun Zhao
    Nuclear Science and Techniques, 2024, 35 (04) : 202 - 209
  • [37] A Pixel Matrix Prototype Chip With High-Precision Time Measurement for CMOS Pixel Detectors
    Cheng, B.
    Morel, F.
    Dorokhov, A.
    Pham, H.
    Bertolone, G.
    Himmi, A.
    Colledani, C.
    Qin, J.
    Zhao, L.
    Hu-Guo, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (03) : 491 - 497
  • [38] Effect of multiple coulomb scattering on the beam tests of silicon pixel detectors
    Li, Lan-Kun
    Dong, Ming-Yi
    Gao, Ze
    Jin, Liang-Cheng-Long
    Zhao, Shu-Jun
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (04)
  • [39] Monte Carlo simulation of the imaging properties of scintillator-coated X-ray pixel detectors
    Hjelm, M
    Norlin, B
    Nilsson, HE
    Fröjdh, C
    Badel, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 76 - 85
  • [40] Tissue characterisation by Compton scattering profile measurements using low resolution detectors
    Singh, B
    Tartari, A
    Baraldi, C
    Casnati, E
    PHYSICA MEDICA, 1997, 13 : 354 - 355