Effect of Atrial Septal Defect Shape Evaluated Using Three-Dimensional Transesophageal Echocardiography on Size Measurements for Percutaneous Closure

被引:59
|
作者
Seo, Jeong-Sook [2 ]
Song, Jong-Min [1 ]
Kim, Young-Hak
Park, Duk-Woo
Lee, Seung-Whan
Kim, Won-Jang
Kim, Dae-Hee
Kang, Duk-Hyun
Song, Jae-Kwan
机构
[1] Univ Ulsan, Coll Med, Dept Cardiol, Asan Med Ctr,Div Cardiol, Seoul 138736, South Korea
[2] Inje Univ, Busan Paik Hosp, Dept Cardiol, Pusan, South Korea
关键词
Atrial septal defect; Three-dimensional echocardiography; Percutaneous closure; TRANSCATHETER CLOSURE; MAGNETIC-RESONANCE; PATIENT SELECTION; DEVICE; OCCLUDER; CARDIOSEAL; EXPERIENCE; MORPHOLOGY; OCCLUSION; DOPPLER;
D O I
10.1016/j.echo.2012.07.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The effect of the atrial septal defect (ASD) shape on ASD size measurements remains unclear. We assessed the relationships between the stretched balloon diameter (SBD) and the diameters measured using two-dimensional and three-dimensional (3D) transesophageal echocardiography (TEE) and evaluated the effect of ASD shape on these relationships in patients with secundum ASD. Methods: We prospectively enrolled 107 consecutive patients who underwent transcatheter closure of ASD. The SBDs and ASD diameters on two-dimensional and 3D-TEE were measured. The circular index of the ASD was defined as the ratio of the maximal diameter to the minimal diameter on the 3D-TEE image. All patients were clinically followed up for a median of 1.3 months after the procedure. Results: The correlations and agreements between measurements were significantly better in patients with a round (circular index less than 1.5) than with an oval ASD. The differences between the SBDs and maximal diameter on 3D-TEE images were significantly smaller in patients with a large oval ASD than in the other patients. The differences between the size of the devices finally implanted and maximal diameter on 3D-TEE images were smaller in patients with a large oval than with a round ASD. On multivariate linear regression analysis, a formula of the relationship between the finally selected device size and 3D-TEE parameters was constructed: device size = 0.964 x maximal diameter on 3D-TEE image - 2.622 x circular index + 7.084. No major complications, including device embolization, developed during follow-up. Conclusions: The relationships between the SBDs and maximal diameters measured on two-dimensional and 3D-TEE images are influenced by the ASD shape and size. Therefore, the ASD shape, as well as the size, should be considered when the device size is determined without SBD measurement. (JAm Soc Echocardiogr 2012;25:1031-40.)
引用
收藏
页码:1031 / 1040
页数:10
相关论文
共 50 条
  • [41] Comparison of transthoracic and transesophageal three-dimensional echocardiography for assessment of atrial septal defect diameter in children
    Acar, P
    Dulac, Y
    Roux, D
    Rougé, P
    Duterque, D
    Aggoun, Y
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (04): : 500 - +
  • [42] Initial experience with real-time three-dimensional transesophageal echocardiography in patients undergoing transcatheter atrial septal defect closure
    Passeri, Jonathan J.
    Inglessis, Ignacio
    Palacios, Igor F.
    Picard, Michael H.
    CIRCULATION, 2007, 116 (16) : 401 - 401
  • [43] Utility of Intraoperative Three-Dimensional Transesophageal Echocardiography in a Patient With Embolized Atrial Septal Defect Closure Device for Emergency Cardiac Surgery
    Manikandan, Sethuraman
    Neema, Praveen Kumar
    Rathod, Ramesh Chandra
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (04) : 730 - 731
  • [44] THE RELATION BETWEEN ATRIAL SEPTAL DEFECT AREA, DIAMETER AND SHAPE USING BALLOON SIZING AND THREE-DIMENSIONAL TRANSOESOPHAGEAL ECHOCARDIOGRAPHY DURING PERCUTANEOUS CLOSURE USING OCCLUTECH DEVICE
    Kong, William K. F.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1493 - 1493
  • [45] Role of three dimensional transesophageal echocardiography in transcatheter closure of atrial septal aneurysms
    Taha, Fatma Aboalsoud
    Elshedoudy, Sahar Abdallah
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0A) : A11 - A11
  • [46] Three-Dimensional Printing Model-Guided Percutaneous Closure of Atrial Septal Defect
    Luo, Hongxing
    Xu, Yu
    Wang, Zhongmin
    Liu, Yuhao
    Gao, Chuanyu
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2017, 108 (05) : 484 - 485
  • [47] Three-dimensional echocardiography in transcatheter closure of atrial septal defects
    Acar, P
    CARDIOLOGY IN THE YOUNG, 2000, 10 (05) : 484 - 492
  • [48] Bifid Atrial Septal Aneurysm: Visualization with Three-Dimensional Transesophageal Echocardiography
    Matyal, Robina
    Warraich, Haider Javed
    Panzica, Peter
    Khabbaz, Kamal R.
    Mahmood, Feroze
    ANESTHESIA AND ANALGESIA, 2011, 112 (06): : 1300 - 1302
  • [49] The role of 3D transesophageal echocardiography during percutaneous closure of atrial septal defect
    Mohamed, Alaa Abdel Moneim
    Ahmed, Omran S.
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2009, 21 (04) : 249 - 251
  • [50] Anatomic correlation of atrial septal defects by three-dimensional transesophageal echocardiography
    Roldan, F. J.
    Vargas-Barron, J.
    Antona, C. Vazquez
    Cardenas, A. Romero
    Castellanos, L. Munoz
    Orellana, J. Erdmenger
    EUROPEAN HEART JOURNAL, 2006, 27 : 796 - 796