Comparison of VIDAS and Radioimmunoassay Methods for Measurement of Cortisol Concentration in Bovine Serum

被引:10
|
作者
Proverbio, Daniela [1 ]
Perego, Roberta [1 ]
Spada, Eva [1 ]
de Giorgi, Giada Bagnagatti [1 ]
Belloli, Angelo [1 ]
Pravettoni, Davide [1 ]
机构
[1] Univ Milan, Dipartimento Sci Vet Salute Prod Anim & Sicurezza, I-20133 Milan, Italy
来源
关键词
PLASMA-CORTISOL; DAIRY-COWS; VALIDATION; BLOOD; CATTLE; CASTRATION; HORMONE; STRESS; CALVES; TESTS;
D O I
10.1155/2013/216569
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radioimmunoassay (RIA) is the "gold standard" method for evaluation of serum cortisol concentration. The VIDAS cortisol test is an enzyme-linked fluorescent assay designed for the MiniVidas system. The aim of this study was to compare the VIDAS method with RIA for measurement of bovine serum cortisol concentration. Cortisol concentrations were evaluated in 40 cows using both VIDAS and RIA methods, the latter as the reference method. A paired Student's t-test, Pearson's correlation analysis, Bland-Altman plot, and Deming regression analysis were used to compare the two methods. There was no statistically significant difference between mean serum cortisol concentrations measured by VIDAS or RIA methods (P = 0.6570). Both methods were able to detect significant differences in mean low and high cortisol concentrations (P < 0.00014 RIA and P < 0.0016 VIDAS). The correlation coefficient was low, but a Bland-Altman plot and Deming regression analysis show neither constant nor proportional error. The VIDAS method produced slightly higher values than RIA, but the difference was small and in no case did the mean value move the normal range. Results suggest that VIDAS method is suitable for the determination of bovine serum cortisol concentration in studies of large numbers of animals.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Comparison of the VIDAS and IMMULITE-2000 methods for cortisol measurement in canine serum
    Proverbio, Daniela
    Groppetti, Debora
    Spada, Eva
    Perego, Roberta
    VETERINARY CLINICAL PATHOLOGY, 2009, 38 (03) : 332 - 336
  • [2] COMPARISON OF SEPARATION METHODS IN THE I125 RADIOIMMUNOASSAY OF SERUM CORTISOL
    GRAY, SM
    SETH, J
    BECKETT, GJ
    ANNALS OF CLINICAL BIOCHEMISTRY, 1983, 20 (SEP) : 312 - 316
  • [3] Comparison of the DPC, DSL and DiaSorin radioimmunoassay methods for the measurement of cortisol in saliva.
    Nadkarni, S
    Slaughter, EH
    Bryan, KA
    Collins, J
    Freer, DE
    CLINICAL CHEMISTRY, 1999, 45 (06) : A88 - A89
  • [4] RADIOIMMUNOASSAY FOR SERUM CORTISOL WITH I-125-LABELED LIGAND - COMPARISON OF 3 METHODS
    KUMAR, MS
    SAFA, AM
    DEODHAR, SD
    CLINICAL CHEMISTRY, 1976, 22 (11) : 1845 - 1849
  • [5] ON THE COMPARISON OF SERUM CORTISOL BY DIRECT RADIOIMMUNOASSAY AND FLUOROMETRIC METHOD
    KANLUAN, T
    PLOYBUTR, S
    VICHAYANRAT, A
    JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND, 1982, 65 (05): : 263 - 270
  • [6] Comparison of the Vcheck and IMMULITE 2000 methods for cortisol measurement in canine serum
    Adaszek, Lukasz
    Teodorowski, Oliwier
    Staniec, Marta
    Janecki, Radoslaw
    Jackowska-Pejko, Natalia
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2021, 77 (08): : 397 - 400
  • [7] Measurement of beta(2)-microglobulin in bovine serum and urine by radioimmunoassay
    Kunugiyama, I
    Ito, N
    Takagaki, Y
    Hayashi, S
    Sone, K
    Gotoh, H
    Saitoh, T
    Furukawa, Y
    Yamaguchi, T
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1996, 58 (07): : 617 - 622
  • [8] COMPARISON OF 3 RADIOIMMUNOASSAY TECHNIQUES FOR MEASUREMENT OF SERUM FOLATE
    BROWN, ML
    CARRETTA, RF
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 746 - 747
  • [9] COMPARISON OF 3 RADIOIMMUNOASSAY TECHNIQUES FOR MEASUREMENT OF SERUM IGE
    POLMAR, SH
    WALDMANN, TA
    TERRY, WD
    JOURNAL OF IMMUNOLOGY, 1973, 110 (05): : 1253 - 1261
  • [10] PROBLEMS IN AUTOMATION OF SERUM CORTISOL RADIOIMMUNOASSAY
    STALLA, G
    MULLER, OA
    WOOD, WG
    SCRIBA, PC
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1978, 290 (02): : 168 - 169