Experimental Realization of a Metamaterial Detector Focal Plane Array

被引:78
|
作者
Shrekenhamer, David [1 ]
Xu, Wangren [2 ]
Venkatesh, Suresh [3 ]
Schurig, David [3 ]
Sonkusale, Sameer [2 ]
Padilla, Willie J. [1 ]
机构
[1] Boston Coll, Dept Phys, 140 Commonwealth Ave, Chestnut Hill, MA 02467 USA
[2] Tufts Univ, NanoLab, Medford, MA 02155 USA
[3] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会;
关键词
TERAHERTZ; MICROWAVE; ANTENNAS; WAVE;
D O I
10.1103/PhysRevLett.109.177401
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We present a metamaterial absorber detector array that enables room-temperature, narrow-band detection of gigahertz (GHz) radiation in the S band (2-4 GHz). The system is implemented in a commercial printed circuit board process and we characterize the detector sensitivity and angular dependence. A modified metamaterial absorber geometry allows for each unit cell to act as an isolated detector pixel and to collectively form a focal plane array. Each pixel can have a dedicated microwave receiver chain and functions together as a hybrid device tuned to maximize the efficiency of detected power. The demonstrated subwavelength pixel shows detected sensitivity of -77 dBm, corresponding to a radiation power density of 27 nW/m(2), with pixel to pixel coupling interference below -14 dB at 2.5 GHz.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Practical tests of a focal plane array detector microscope at the ANKA-IR beamline
    Moss, David
    Gasharova, Biliana
    Mathis, Yves-Laurent
    INFRARED PHYSICS & TECHNOLOGY, 2006, 49 (1-2) : 53 - 56
  • [42] Analysis on Reliability of Cooling Head in Large-array Infrared Focal Plane Detector
    Li Xueli
    Zhang Lei
    Ning Ti
    Wang Chenggang
    AOPC 2020: INFRARED DEVICE AND INFRARED TECHNOLOGY, 2020, 11563
  • [43] Experimental implementations of 2D IR spectroscopy through a horizontal pulse shaper design and a focal plane array detector
    Ghosh, Ayanjeet
    Serrano, Arnaldo L.
    Oudenhoven, Tracey A.
    Ostrander, Joshua S.
    Eklund, Elliot C.
    Blair, Alexander F.
    Zanni, Martin T.
    OPTICS LETTERS, 2016, 41 (03) : 524 - 527
  • [44] Focal plane detector optical readout
    Gallo, G.
    Bonanno, D. L.
    Bongiovanni, D. G.
    Cappuzzello, F.
    Cortesi, M.
    Longhitano, F.
    Lo Presti, D.
    Pandola, L.
    Reito, S.
    CONFERENCE ON NEUTRINO AND NUCLEAR PHYSICS (CNNP2017), 2018, 1056
  • [45] FOCAL PLANE DETECTOR FOR BROOKHAVEN QDDD
    IWATA, S
    BEARDSWO.E
    FISCHER, J
    LEVINE, MJ
    RADEKA, V
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 528 - 528
  • [46] Dark current measurement of Type-II superlattice infrared focal plane array detector
    Sakai, Michito
    Katayama, Haruyoshi
    Murooka, Junpei
    Kimata, Masafumi
    Iguchi, Yasuhiro
    INFRARED TECHNOLOGY AND APPLICATIONS XL, 2014, 9070
  • [47] Research on the Neas Infrared Focal Plane Array Detector Imaging Technology Used in the Laser Warning
    Wang Zhi-bin
    Huang Yan-fei
    Wang Yao-li
    Zhang Rui
    Wang Yan-chao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (04) : 1140 - 1143
  • [48] Effect of the grating shape on the response spectrum of quantum well infrared detector focal plane array
    Du, Wei
    Wang, Jiqiang
    Li, Ning
    Li, Xiangyang
    Xu, Jintong
    OPTICS COMMUNICATIONS, 2023, 546
  • [49] FOURIER-TRANSFORM SPECTROSCOPIC IMAGING USING AN INFRARED FOCAL-PLANE ARRAY DETECTOR
    LEWIS, EN
    TREADO, PJ
    REEDER, RC
    STORY, GM
    DOWREY, AE
    MARCOTT, C
    LEVIN, IW
    ANALYTICAL CHEMISTRY, 1995, 67 (19) : 3377 - 3381
  • [50] Stress in HgCdTe large infrared focal plane array detector analyzed with finite element analysis
    Zhang Wei-Ting
    Chen Xing
    Ye Zhen-Hua
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2021, 40 (03) : 308 - 313