Poststenting axial redistribution of atherosclerotic plaque into the reference segments and lumen reduction at the stent edge - A volumetric intravascular ultrasound study

被引:5
|
作者
Algowhary, M
Matsumura, A
Hashimoto, Y
Isobe, M
机构
[1] Tokyo Med & Dent Univ, Dept Cardiovasc Med, Bunkyo Ku, Tokyo 1138519, Japan
[2] Kameda Med Ctr, Dept Cardiol, Chiba, Japan
关键词
prospective study; volumetric IVUS; plaque shift; stent edge;
D O I
10.1536/ihj.47.159
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Lumen enlargement during coronary stenting results from vessel expansion and axial redistribution of atheromatous plaque along the stented segment and proximal and distal reference segments. Plaque burden predicts stenosis at the stent edge. The aim of this study was to investigate the fate of shifted plaque with special reference to whether or not plaque shift (PSh) correlates with late lumen reduction. This is a prospective study conducted on 54 consecutive patients who underwent bare metal stenting. In all stent edges (108 edges), PSh volume was measured as post intervention plaque-media volume (PMV) minus preintervention PMV. Changes in lumen volume (Delta LV), vessel volume (Delta VV), and PMV (Delta PMV) were measured by serial intravascular ultrasound (IVUS) examination. After stenting, PSh was detected in 81.5% of proximal edges versus 72.2% of distal edges (P = 0.36). It correlated significantly with Delta VV (r = 0.34, P = 0.002), and inversely with Delta LV (r = 0.32, P = 0.003). However, at 6-month follow-Lip, it did not correlate with ALV (r = -0.03, P = 0.8), Delta VV (r = 0.1, P = 0.6), or Delta PMV (r = 0.1. P = 0.4). Furthermore, ALV correlated more strongly with Delta VV (r = 0.62, P < 0.00001) than with Delta PMV (r = -0.39, P = 0.001). By multivariate analysis, PSh area was an independent predictor of the postintervention change in lumen area (partial eta squared 0.21, P = 0.01), but not the follow-up change. Two patients (3.7%) developed proximal edge stenosis with no evident PSh after stenting. Thus, axial redistribution of atheromatous plaque into the reference segments was frequently encountered after stenting. Although PSh correlated with the immediate reduction in stent edge lumen volume, it did not correlate with the late lumen reduction.
引用
收藏
页码:159 / 171
页数:13
相关论文
共 27 条
  • [21] Variation of plaque composition and tissue redistribution after balloon angioplasty in coronary atherosclerotic lesions: Study using "Virtual histology" by spectral analysis of intravascular ultrasound radiofrequency data
    Wei, Hu
    Genon, Vincent Descotes
    Legalery, Pierre
    Seronde, Marie-France
    Meneveau, Nicolas
    Bassand, Jean-Pierre
    Schiele, Francois
    CIRCULATION, 2006, 114 (18) : 324 - 324
  • [22] Is there any deleterious change on the vessel wall of in-stent overlapping sirolimus segment when compared with non-overlapping sirolimus segments?: A volumetric intravascular ultrasound study
    Muñoz, JS
    Abizaid, A
    Abizaid, AS
    Feres, F
    Staico, R
    Mottos, LA
    Sousa, A
    Mintz, GS
    Sousa, JE
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 181L - 182L
  • [23] The relationship among extent of lipid-rich plaque, factors associated with a reduction of lipid-rich plaque and late lumen loss: a near-infrared spectroscopy and intravascular ultrasound study
    Takahashi, N.
    Dohi, T.
    Endo, H.
    Nishio, R.
    Fukase, T.
    Takeuchi, M.
    Doi, S.
    Kato, Y.
    Okai, I.
    Iwata, H.
    Okazaki, S.
    Isoda, K.
    Miyauchi, K.
    Daida, H.
    Minamino, T.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1189 - 1189
  • [24] Can stent/lesion length ratio influence the edge effect after implantation of drug-eluting and non-eluting stents?: A volumetric intravascular ultrasound study
    Muñoz, JS
    Abizaid, A
    Feres, F
    Ferreira, E
    Abizaid, AS
    Mattos, LA
    Staico, R
    Maldonado, G
    Vaz, VD
    Centemero, M
    Chaves, A
    Tanajura, LF
    Pinto, I
    Sousa, A
    Mintz, GS
    Sousa, JE
    CIRCULATION, 2004, 110 (17) : 734 - 734
  • [25] Can stent/lesion length ratio influence the edge effect after implantation of drug-eluting and bare-metal stents?: A volumetric intravascular ultrasound study.
    Muñoz, JS
    Abizaid, A
    Albertal, M
    Feres, F
    Ferreira, EJ
    Abizaid, AS
    Mattos, LA
    Staico, R
    Maldonado, G
    Vaz, VD
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 214E - 215E
  • [26] Reduction of atherothrombotic burden before stent deployment in non-ST elevation acute coronary syndromes: Reduction of myocardial necrosis achieved with nose-dive manual thrombus aspiration (REMNANT) trial. A volumetric intravascular ultrasound study
    Zimarino, Marco
    Angeramo, Francesca
    Prasad, Abhiram
    Ruggieri, Benedetta
    Malatesta, Sara
    Prati, Francesco
    Buttitta, Fiamma
    De Caterina, Raffaele
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (05) : 716 - 725
  • [27] Prospective Validation of Standardized, 3-Dimensional, Quantitative Coronary Computed Tomographic Plaque Measurements Using Radiofrequency Backscatter Intravascular Ultrasound as Reference Standard in Intermediate Coronary Arterial Lesions Results From the ATLANTA (Assessment of Tissue Characteristics, Lesion Morphology, and Hemodynamics by Angiography With Fractional Flow Reserve, Intravascular Ultrasound and Virtual Histology, and Noninvasive Computed Tomography in Atherosclerotic Plaques) I Study
    Voros, Szilard
    Rinehart, Sarah
    Qian, Zhen
    Vazquez, Gustavo
    Anderson, Hunt
    Murrieta, Laura
    Wilmer, Charles
    Carlson, Harold
    Taylor, Kenneth
    Ballard, William
    Karmpaliotis, Dimitri
    Kalynych, Anna
    Brown, Charles, III
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (02) : 198 - 208