A Sphere-Based Calibration Method for Line Structured Light Vision Sensor

被引:4
|
作者
Wei, Zhenzhong [1 ]
Shao, Mingwei [1 ]
Wang, Yali [1 ]
Hu, Mengjie [1 ]
机构
[1] Beihang Univ, Minist Educ, Key Lab Precis Optomech Technol, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1155/2013/580417
中图分类号
O414.1 [热力学];
学科分类号
摘要
A major difficulty in calibrating line structured light vision sensor is how to obtain enough calibration feature points, due to the fact that known world points on the calibration target do not rightly fall onto the light stripe plane. This paper presents a calibration method using a target, consisting of one sphere and a reference board, to obtain feature points on the light stripe, which is the intersection of the structured-light plane and the reference board. By moving the sphere into several positions on the fixed reference board, we can get a plane in parallel with the reference one. From the acquired right-circular cone and known radius of the sphere, the function of the reference board can be deduced. Moving the target randomly into different positions, enough points lying on the structured-light plane can be obtained. Experiment results show that the accuracy of the proposed calibration method can reach 0.102 mm within the view field of 200 mm * 200 mm; meanwhile, robustness and easy operation can be indicated.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Fast method to calibrate structure parameters of line structured light vision sensor
    Han, Jian-Dong
    Lü, Nai-Guang
    Dong, Ming-Li
    Lou, Xiao-Ping
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (05): : 958 - 963
  • [42] Research on the Method to Calibrate Structure Parameters of Line Structured Light Vision Sensor
    Niu, Mingang
    Zhao, Kangnian
    Wan, Jie
    Li, Yanyan
    Liu, Shuzhong
    Proceedings of the 2016 International Conference on Mechanics, Materials and Structural Engineering (ICMMSE), 2016, 29 : 377 - 382
  • [43] Research on Line Structured Light Calibration Method
    Chang, Wenhui
    Jing, Li
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 65 - 69
  • [44] Improvement of calibration method for multi-camera line structured light vision system
    Hongmai Yang
    Changshuai Fang
    Xiaodong Zhang
    Applied Physics B, 2022, 128
  • [45] Calibration Method for Line-Structured Light
    Zhang Ruifeng
    Shu Ziyun
    Nan Ganglei
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (22)
  • [46] Improvement of calibration method for multi-camera line structured light vision system
    Yang, Hongmai
    Fang, Changshuai
    Zhang, Xiaodong
    APPLIED PHYSICS B-LASERS AND OPTICS, 2022, 128 (06):
  • [47] A Cylinder Based Calibration Method for Integrating a Line Structured Light Sensor with a Rotation-translation Platform
    Zhou, Jingbo
    Li, Yuehua
    Liu, Lijian
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [48] Research on calibration method for line-structured light sensor based on spatial quadratic surface fitting
    Zhu, Linwei
    Cheng, Xiaoqi
    Li, Xiaosong
    Tan, Haishu
    Chen, Hujun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)
  • [49] An On-Line Measurement Method of the Medium Thickness Steel Plate Based on Structured Light Vision Sensor
    Zhengnan Li
    Miaomiao Zhang
    Bin Zheng
    Lidong Ma
    International Journal of Precision Engineering and Manufacturing, 2023, 24 : 1903 - 1914
  • [50] An On-Line Measurement Method of the Medium Thickness Steel Plate Based on Structured Light Vision Sensor
    Li, Zhengnan
    Zhang, Miaomiao
    Zheng, Bin
    Ma, Lidong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2023, 24 (10) : 1903 - 1914