Simple pencil-drawn paper-based devices for one-spot electrochemical detection of electroactive species in oil samples

被引:27
|
作者
Dossi, Nicolo [1 ]
Toniolo, Rosanna [1 ]
Terzi, Fabio [2 ]
Piccin, Evandro [3 ]
Bontempelli, Gino [1 ]
机构
[1] Univ Udine, Dept Food Sci, I-33100 Udine, Italy
[2] Univ Modena & Reggio Emilia, Dept Chem & Geol Sci, Modena, Italy
[3] Univ Fed Minas Gerais, Dept Chem, Belo Horizonte, MG, Brazil
关键词
Edible oils; Extra virgin olive oil; Ortho-diphenols; Paper-based electrochemical devices (PEDs); Pencil-drawn electrodes (PDEs); Voltammetric analysis; VIRGIN OLIVE OIL; TEMPERATURE IONIC LIQUIDS; CARBON-PASTE ELECTRODES; PHENOLIC-COMPOUNDS; MICROCHIP ELECTROPHORESIS; AMPEROMETRIC DETECTION; ANTIOXIDANT ACTIVITY; LOW-COST; POLYPHENOLS; ARRAY;
D O I
10.1002/elps.201500083
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We propose here simple electrochemical cells assembled with electrodes pencil drawn on paper for conducting one-spot tests enabling olive oil to be easily distinguished from other vegetable oils. They consist of small circular pads of hydrophilic paper defined by hydrophobic barriers, these last printed by using custom-designed rubber stamps, where working, reference, and counterelectrodes are drawn by pencil leads. These cells were first wetted with a small volume of aqueous electrolyte, avoiding coating of the upper surface of electrodes. A controlled volume of edible oil samples was then applied on top of the moist cell. The results found proved that these devices can be adopted as effective platforms suitable for the detection of electroactive compounds present in edible oils. In fact, they allow voltammetric profiles to be recorded not only for the oxidation of water soluble species (ortho-diphenols, as well as some monophenols and polyphenols) present in olive oils, but also for electroactive hydrophobic components (e.g., -tocopherol) present in sunflower oils, which were chosen as model of seed oils. The whole of collected findings pointed out that simple one-spot tests performed by these devices enable olive oils to be easily distinguished from other edible oils on the basis of their clearly different voltammetric profiles. A satisfactory interdevice reproducibility (+/- 13%) was estimated by applying strictly similar extra virgin olive oil samples onto seven different cells carefully prepared by the same procedure. An operating mechanism able to account for the detection of also electroactive hydrophobic compounds present in oils is proposed.
引用
收藏
页码:1830 / 1836
页数:7
相关论文
共 50 条
  • [41] Paper-based electrochemical sensors with reduced graphene nanoribbons for simultaneous detection of sulfamethoxazole and trimethoprim in water samples
    Martins, Thiago S.
    Bott-Neto, Jose L.
    Oliveira, Osvaldo N., Jr.
    Machado, Sergio A. S.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 882
  • [42] From glow-sticks to sensors: single-electrode electrochemical detection for paper-based devices
    Vidal, Ezequiel
    Domini, Claudia E.
    Whitehead, Daniel C.
    Garcia, Carlos D.
    SENSORS & DIAGNOSTICS, 2022, 1 (03): : 496 - 503
  • [43] A simple cost-effective paper-based electrochemical device for detection of adulterated sibutramine in slimming products
    Sirivibulkovit, Kitima
    Wilairat, Prapin
    Nacapricha, Duangjai
    Wichit, Sineewanlaya
    Saetear, Phoonthawee
    ANALYTICAL METHODS, 2022, 14 (25) : 2461 - 2470
  • [44] Facile fabrication of paper-based analytical devices for rapid and highly selective colorimetric detection of cesium in environmental samples
    Kang, Sung-Min
    Jang, Sung-Chan
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Roh, Changhyun
    Han, Young-Kyu
    Huh, Yun Suk
    RSC ADVANCES, 2017, 7 (76) : 48374 - 48385
  • [45] Immobilization of diphenylcarbazide on paper-based analytical devices for the pre-concentration and detection of chromium VI in water samples
    Ben Jaballah, Menyar
    Karrat, Abdelhafid
    Amine, Aziz
    Dridi, Cherif
    TALANTA, 2023, 265
  • [46] Target-Induced DNA Mismatch for One-Spot Simultaneous Electrochemical Detection of Multiple Heavy Metals Based on the Amplification of DNA Concatemers
    Liu, Guangpeng
    Wang, Haijun
    Yuan, Yali
    Wang, Jianli
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (04) : B81 - B85
  • [47] Flow-Through Carbon Nanofiber-Based Transducer for Inline Electrochemical Detection in Paper-Based Analytical Devices
    Perju, Antonia
    Holzhausen, Ferdinand
    Lauerer, Anna-Maria
    Wongkaew, Nongnoot
    Baeumner, Antje J.
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (38) : 44641 - 44653
  • [48] Three-dimensional paper-based microfluidic electrochemical integrated devices (3D-PMED) for wearable electrochemical glucose detection
    Cao, Qingpeng
    Liang, Bo
    Tu, Tingting
    Wei, Jinwei
    Fang, Lu
    Ye, Xuesong
    RSC ADVANCES, 2019, 9 (10): : 5674 - 5681
  • [49] Recent Developments of Three-Dimensional Paper-Based Electrochemical Devices for Cancer Cell Detection and Anticancer Drug Screening
    Li, Zedong
    Hu, Jie
    Xu, Feng
    Li, Fei
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2016, 17 (09) : 802 - 809
  • [50] Paper-Based Analytical Devices for the Rapid and Direct Electrochemical Detection of Hydrogen Peroxide in Tomato Leaves Inoculated with Botrytis cinerea
    Sun, Lijun
    Pan, Yu
    Wu, Jin
    Zhao, Danyang
    Hui, Meiqi
    Zhu, Suqin
    Zhu, Xinyu
    Li, Dayong
    Song, Fengming
    Zhang, Cankui
    SENSORS, 2020, 20 (19)