THE STATUS OF THE QUIJOTE MULTI-FREQUENCY INSTRUMENT

被引:18
|
作者
Hoyland, R. J. [1 ]
Aguiar-Gonzalez, M. [1 ]
Aja, B.
Arino, J.
Artal, E.
Barreiro, R. B.
Blackhurst, E. J.
Cagigas, J.
Cano de Diego, J. L.
Casas, F. J.
Davis, R. J.
Dickinson, C.
Arriaga, B. E.
Fernandez-Cobos, R.
de la Fuente, L.
Genova-Santos, R. [1 ]
Gomez, A.
Gomez, C.
Gomez-Renasco, F. [1 ]
Grainge, K.
Harper, S.
Herran, D.
Herreros, J. M. [1 ]
Herrera, G. A.
Hobson, M. P.
Lasenby, A. N.
Lopez-Caniego, M.
Lopez-Caraballo, C. [1 ]
Maffei, B.
Martinez-Gonzalez, E.
McCulloch, M.
Melhuish, S.
Mediavilla, A.
Murga, G.
Ortiz, D.
Piccirillo, L.
Pisano, G.
Rebolo-Lopez, R. [1 ]
Rubino-Martin, J. A. [1 ]
Luis Ruiz, J.
Sanchez de la Rosa, V. [1 ]
Sanquirce, R.
Vega-Moreno, A. [1 ]
Vielva, P.
Viera-Curbelo, T. [1 ]
Villa, E.
Vizcargueenaga, A.
Watson, R. A.
机构
[1] IAC, C Via Lactea S-N, E-38200 Tenerife, Spain
来源
MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI | 2012年 / 8452卷
关键词
polarization; CMBr; instrumentation; spectrometer; foregrounds; B-modes; mapping;
D O I
10.1117/12.925349
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The QUIJOTE-CMB project has been described in previous publications. Here we present the current status of the QUIJOTE multi-frequency instrument (MFI) with five separate polarimeters (providing 5 independent sky pixels): two which operate at 10-14 GHz, two which operate at 16-20 GHz, and a central polarimeter at 30 GHz. The optical arrangement includes 5 conical corrugated feedhorns staring into a dual reflector crossed-draconian system, which provides optimal cross-polarization properties (designed to be < -35 dB) and symmetric beams. Each horn feeds a novel cryogenic on-axis rotating polar modulator which can rotate at a speed of up to 1 Hz. The science driver for this first instrument is the characterization of the galactic emission. The polarimeters use the polar modulator to derive linear polar parameters Q, U and I and switch out various systematics. The detection system provides optimum sensitivity through 2 correlated and 2 total power channels. The system is calibrated using bright polarized celestial sources and through a secondary calibration source and antenna. The acquisition system, telescope control and housekeeping are all linked through a real-time gigabit Ethernet network. All communication, power and helium gas are passed through a central rotary joint. The time stamp is synchronized to a GPS time signal. The acquisition software is based on PLCs written in Beckhoffs TwinCat and ethercat. The user interface is written in LABVIEW. The status of the QUIJOTE MFI will be presented including pre-commissioning results and laboratory testing.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Status of the new multi-frequency ECRH system for ASDEX Upgrade
    Wagner, D.
    Gruenwald, G.
    Leuterer, F.
    Manini, A.
    Monaco, F.
    Muenich, M.
    Schuetz, H.
    Stober, J.
    Zohm, H.
    Franke, T.
    Thumm, M.
    Gantenbein, G.
    Heidinger, R.
    Meier, A.
    Kasparek, W.
    Lechte, C.
    Litvak, A.
    Denisov, G. G.
    Chirkov, A. V.
    Tai, E. M.
    Popov, L. G.
    Nichiporenko, V. O.
    Myasnikov, V. E.
    Solyanova, E. A.
    Malygin, S. A.
    Meo, F.
    Woskov, P.
    NUCLEAR FUSION, 2008, 48 (05)
  • [12] Imaging and detection of cracks based on a multi-frequency electromagnetic scanning instrument and SVM
    Yin, Liyuan
    Wu, Jiande
    Ye, Bo
    Avila, Jorge Salas
    Xu, Hanyang
    How, Kin Yau
    Tao, Yang
    Yin, Wuliang
    2017 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2017, : 378 - 382
  • [13] Multi-frequency synthesis
    Sault, RJ
    Conway, JE
    SYNTHESIS IMAGING IN RADIO ASTRONOMY II, 1999, 180 : 419 - 432
  • [14] Multi-Frequency Tympanometry: Clinical Applications for the Assessment of the Middle Ear Status
    Emily Iacovou
    Petros V. Vlastarakos
    Eleftherios Ferekidis
    Thomas P. Nikolopoulos
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2013, 65 : 283 - 287
  • [15] Multi-Frequency Tympanometry: Clinical Applications for the Assessment of the Middle Ear Status
    Iacovou, Emily
    Vlastarakos, Petros V.
    Ferekidis, Eleftherios
    Nikolopoulos, Thomas P.
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2013, 65 (03) : 283 - 287
  • [16] The Multi-Frequency ECRH System at ASDEX Upgrade - Current Status and Plans -
    Wagner, D.
    Stober, J.
    Kircher, M.
    Leuterer, F.
    Monaco, F.
    Muenich, M.
    Schubert, M.
    Zohm, H.
    Gantenbein, G.
    Jelonnek, J.
    Thumm, M.
    Meier, A.
    Scherer, T.
    Strauss, D.
    Kasparek, W.
    Lechte, C.
    Plaum, B.
    Zach, A.
    Litvak, A. G.
    Denisov, G. G.
    Chirkov, A.
    Malygin, V.
    Popov, L. G.
    Nichiporenko, V. O.
    Myasnikov, V. E.
    Tai, E. M.
    Solyanova, E. A.
    2018 43RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2018,
  • [17] Multi-frequency phase-coherent systems: New instrument for space plasma exploration
    Inst. of Radio Eng. and Electronics, Russian Academy of Sciences, 11 Mokhovaya str., Moscow, Russia
    Adv Space Res, 4-5 (381-384):
  • [18] Research and Design of Human Impedance Measuring Instrument Based on the Method of Multi-frequency and Multi-segment
    Chen, Bo
    Zhang, Xueping
    Liu, Na
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 701 - 704
  • [19] Multi-frequency impedance technique
    Caffin, J
    BRITISH JOURNAL OF NUTRITION, 1996, 75 (03) : 508 - 509
  • [20] A multi-frequency quadrature bridge
    Nakamura, Y
    Fukushima, A
    Sakamoto, Y
    Endo, T
    Small, GW
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 42 - 43