THE STATUS OF THE QUIJOTE MULTI-FREQUENCY INSTRUMENT

被引:18
|
作者
Hoyland, R. J. [1 ]
Aguiar-Gonzalez, M. [1 ]
Aja, B.
Arino, J.
Artal, E.
Barreiro, R. B.
Blackhurst, E. J.
Cagigas, J.
Cano de Diego, J. L.
Casas, F. J.
Davis, R. J.
Dickinson, C.
Arriaga, B. E.
Fernandez-Cobos, R.
de la Fuente, L.
Genova-Santos, R. [1 ]
Gomez, A.
Gomez, C.
Gomez-Renasco, F. [1 ]
Grainge, K.
Harper, S.
Herran, D.
Herreros, J. M. [1 ]
Herrera, G. A.
Hobson, M. P.
Lasenby, A. N.
Lopez-Caniego, M.
Lopez-Caraballo, C. [1 ]
Maffei, B.
Martinez-Gonzalez, E.
McCulloch, M.
Melhuish, S.
Mediavilla, A.
Murga, G.
Ortiz, D.
Piccirillo, L.
Pisano, G.
Rebolo-Lopez, R. [1 ]
Rubino-Martin, J. A. [1 ]
Luis Ruiz, J.
Sanchez de la Rosa, V. [1 ]
Sanquirce, R.
Vega-Moreno, A. [1 ]
Vielva, P.
Viera-Curbelo, T. [1 ]
Villa, E.
Vizcargueenaga, A.
Watson, R. A.
机构
[1] IAC, C Via Lactea S-N, E-38200 Tenerife, Spain
来源
MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI | 2012年 / 8452卷
关键词
polarization; CMBr; instrumentation; spectrometer; foregrounds; B-modes; mapping;
D O I
10.1117/12.925349
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The QUIJOTE-CMB project has been described in previous publications. Here we present the current status of the QUIJOTE multi-frequency instrument (MFI) with five separate polarimeters (providing 5 independent sky pixels): two which operate at 10-14 GHz, two which operate at 16-20 GHz, and a central polarimeter at 30 GHz. The optical arrangement includes 5 conical corrugated feedhorns staring into a dual reflector crossed-draconian system, which provides optimal cross-polarization properties (designed to be < -35 dB) and symmetric beams. Each horn feeds a novel cryogenic on-axis rotating polar modulator which can rotate at a speed of up to 1 Hz. The science driver for this first instrument is the characterization of the galactic emission. The polarimeters use the polar modulator to derive linear polar parameters Q, U and I and switch out various systematics. The detection system provides optimum sensitivity through 2 correlated and 2 total power channels. The system is calibrated using bright polarized celestial sources and through a secondary calibration source and antenna. The acquisition system, telescope control and housekeeping are all linked through a real-time gigabit Ethernet network. All communication, power and helium gas are passed through a central rotary joint. The time stamp is synchronized to a GPS time signal. The acquisition software is based on PLCs written in Beckhoffs TwinCat and ethercat. The user interface is written in LABVIEW. The status of the QUIJOTE MFI will be presented including pre-commissioning results and laboratory testing.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Control system architecture of QUIJOTE multi-frequency instrument
    Gomez-Renasco, Maria F.
    Aguiar, Marta
    Herreros, Jose Miguel
    Hoyland, Roger J.
    Sanchez de la Rosa, Vicente
    Vega-Moreno, Afrodisio
    Viera-Curbelo, Teodora
    Genova-Santos, Ricardo
    Lopez-Caraballo, Carlos
    Rebolo, Rafael
    Alberto Rubino-Martin, Jose
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI, 2012, 8452
  • [2] The new Multi-Frequency Instrument (MFI2) for the QUIJOTE facility in Tenerife
    Hoyland, Roger J.
    Alberto Rubino-Martin, Jose
    Aguiar-Gonzalez, Marta
    Alonso-Arias, Paz
    Artal, Eduardo
    Ashdown, Mark
    Barreiro, R. Belen
    Casas, Francisco J.
    Colodro-Conde, Carlos
    de la Hoz, Elena
    Fernandez-Torreiro, Mateo
    Fuerte-Rodriguez, Pablo A.
    Genova-Santos, Ricardo T.
    Gomez-Renasco, Maria F.
    Gonzalez-Carretero, Eduardo D.
    Gonzalez-Gonzalez, Raul
    Guidi, Frederica
    Hernandez-Monteagudo, Carlos
    Herranz, Diego
    Lasenby, Anthony N.
    Lopez-Caraballo, Carlos H.
    Martinez-Gonzalez, Enrique
    Oria-Carreras, Asier
    Peel, Michael W.
    Perez-de-Taoro, Angeles
    Perez-Lemus, Cristina
    Piccirillo, Lucio
    Rebolo, Rafael
    Rodriguez-Diaz, Jesus Salvador
    Toledo-Moreo, Rafael
    Vega-Moreno, Afrodisio
    Vielva, Patricio
    Watson, Robert Anthony
    Zamora-Jimenez, Antonio
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY XI, 2022, 12190
  • [4] Characterisation of a Multi-frequency Wound Impedance Mapping Instrument
    Weber, Sonja. A.
    Gehin, Claudine
    Moddy, Gillian
    Jossinet, Jacques
    McAdams, Eric T.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4907 - +
  • [5] A multi-frequency impedance analysing instrument for eddy current testing
    Yin, W
    Dickinson, SJ
    Peyton, AJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (02) : 393 - 402
  • [6] EIM multi-frequency Measurement System Based on Virtual Instrument
    Zhang, Xianghong
    Xu, Pan
    Wei, Ziliang
    Gao, Yueming
    Vasic, Zeljka Lucev
    Cifrek, Mario
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 111 - 113
  • [7] Development of the multi-frequency multi-channel digital eddy current instrument
    Lin, JM
    Lin, CJ
    Chen, KH
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1663 - 1666
  • [8] Multi-Frequency ECRH at ASDEX Upgrade, Status and Plans
    Wagner, D.
    Stober, J.
    Leuterer, F.
    Monaco, F.
    Muenich, M.
    Schmid-Lorch, D.
    Schuetz, H.
    Zohm, H.
    Thumm, M.
    Scherer, T.
    Meier, A.
    Gantenbein, G.
    Flamm, J.
    Kasparek, W.
    Hoehnle, H.
    Lechte, C.
    Litvak, A. G.
    Denisov, G. G.
    Chirkov, A.
    Popov, L. G.
    Nichiporenko, V. O.
    Myasnikov, V. E.
    Tai, E. M.
    Solyanova, E. A.
    Malygin, S. A.
    35TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ 2010), 2010,
  • [9] Hydration status assessed by multi-frequency bioimpedance analysis
    Asselin, MC
    Kriemler, S
    Chettle, DR
    Webber, CE
    Bar-Or, O
    McNeill, FE
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 495 - 497
  • [10] Multi-frequency Eddy Current Testing using a GMR based instrument
    Bernieri, Andrea
    Betta, Giovanni
    Ferrigno, Luigi
    Laracca, Marco
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2012, 39 (1-4) : 355 - 362