LiF(Mg,Ti) thermoluminescence dosimetry pellets

被引:0
|
作者
Sarraf-Mamoory, R [1 ]
Riahi-Noori, N [1 ]
机构
[1] Tarbiat Modarres Univ, Dept Mat, Tehran, Iran
来源
AMERICAN CERAMIC SOCIETY BULLETIN | 2005年 / 84卷 / 09期
关键词
D O I
暂无
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Assessing the performance of LiF: Mg, Ti dosemeters in extremity dosimetry
    Freire, L. C.
    Calado, A.
    Cardoso, J. V.
    Santos, L. M.
    Alves, J. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S242 - S242
  • [22] From nGy to MGy - new dosimetry with LiF: Mg,Cu,P thermoluminescence detectors
    Obryk, Barbara
    XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 : 22 - 29
  • [23] THERMOLUMINESCENCE AND COLOR CENTER CORRELATIONS IN DOSIMETRY LIF
    MAYHUGH, MR
    CHRISTY, RW
    JOHNSON, NM
    JOURNAL OF APPLIED PHYSICS, 1970, 41 (07) : 2968 - &
  • [24] The effect of optical bleaching at selected photon energies on the thermoluminescence of LiF: Mg, Ti
    Reshes, G.
    Druzhyna, S.
    Biderman, S.
    Eliyahu, I.
    Oster, L.
    Horowitz, Y. S.
    2016 INTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS (ICDIM 2016), 2017, 169
  • [25] Thermoluminescence glow peak parameters for LiF:Mg,Ti with modified activator concentration
    Puchalska, M.
    Bilski, P.
    Olko, P.
    RADIATION MEASUREMENTS, 2007, 42 (4-5) : 601 - 604
  • [26] REVIEW OF DOSE-RATE EFFECTS IN THE THERMOLUMINESCENCE OF LiF: Mg, Ti (HARSHAW)
    Horowitz, Yigal
    Oster, Leonid
    Eliyahu, Ilan
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (02) : 184 - 188
  • [27] Sensitivity of LiF:Mg,Ti thermoluminescence detectors after various annealing procedures
    Kitis, G
    Tuyn, JWN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 132 (04): : 639 - 646
  • [28] Variability characteristics of the HTTL to dosimetry peaks ratio in LiF:Mg,Ti
    Abraham, A.
    Weinstein, M.
    German, U.
    Alfassi, Z. B.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1732 - 1736
  • [29] LIF DOSIMETRY .2. EFFECTS OF MG AND TI ON THERMOLUMINESCENT EMISSION-SPECTRA OF LIF
    CRITTENDEN, GC
    TOWNSEND, PD
    GILKES, J
    WINTERSGILL, MC
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1974, 7 (17) : 2410 - 2421
  • [30] Evaluation of the entrance skin dose in animals undergoing diagnostic radiology using LiF, Mg, Ti thermoluminescence dosimetry (TLD-100)
    Sina S.
    Mirzaiee F.
    Padargani T.
    Zehtabian M.
    Ahrari S.
    Zehtabian, Mehdi (mehdizehtabian@yahoo.com), 1600, Mashhad University of Medical Sciences (13): : 118 - 124