A Comparative Study of Control Techniques of Distribution-STATCOM under Abnormal Source Voltage

被引:0
|
作者
Bajaj, Mohit [1 ]
Bhardwaj, Chetan [1 ]
Pushkarna, Mukesh [2 ]
机构
[1] DIT Univ, Dept Elect Engn, Dehra Dun 248009, India
[2] Quantum Inst Technol, Dept Elect Engn, Roorkee 247667, Uttar Pradesh, India
关键词
Reactive current; Compensation current; Instantaneous Reactive Power; Detection; Harmonics; Reference Frame; Simulation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The most important concern regarding a power system is the quality of its power. The main cause of most of the issues is nonlinear loads only. D-STATCOM has turned out to be a good solution to solve this problem because of its ability to compensate reactive power and harmonic components demand of the nonlinear loads. This paper presents comprehensive analysis of comparison the performance of five control techniques for reference currents extraction of D-STATCOM under balanced, un-balanced and distorted voltage condition. The algorithms to be compared are symmetrical components based algorithm, IRP theory, generalized IRP theory, SRF method, and synchronous detection method respectively those are widely used in D-STATCOM. These all algorithms have been simulated in Matlab/Simulink environment. The theoretical study and simulation testing shows the performance and accuracy of considered algorithms in case of balanced unbalanced and distorted source voltage conditions.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 50 条
  • [31] Comparative study of two repetitive process control techniques for a grid-tie converter under distorted grid voltage conditions
    Jackiewicz, Krzysztof
    Stras, Andrzej
    Ufnalski, Bartlomiej
    Grzesiak, Lech
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 113 : 164 - 175
  • [32] Voltage Source Converter Control under Unbalanced Grid Voltage Conditions
    Rasool, Akhtar
    Ahmad, Fiaz
    Sabanovic, Asif
    2017 XXVI INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT), 2017,
  • [33] Distribution System Voltage Control under Uncertainties
    Li, Pan
    Zhang, Baosen
    2017 FIFTY-FIRST ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS, AND COMPUTERS, 2017, : 659 - 663
  • [34] Voltage Control of a StatCom at a Fixed Speed Wind Farm under Unbalanced Grid Faults
    Wessels, Christian
    Fuchs, Friedrich W.
    Molinas, Marta
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 979 - 984
  • [35] A comparative study of glottal source estimation techniques
    Drugman, Thomas
    Bozkurt, Baris
    Dutoit, Thierry
    COMPUTER SPEECH AND LANGUAGE, 2012, 26 (01): : 20 - 34
  • [36] Comparative Study of Voltage Stability Enhancement of a Grid and Loss Reduction Using STATCOM and SSSC
    Hridya, K. R.
    Mini, V
    Visakhan, R.
    Kurian, Asha Anu
    PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON POWER, INSTRUMENTATION, CONTROL AND COMPUTING (PICC), 2015,
  • [37] Voltage sag mitigation using a new direct control in d-statcom for distribution systems
    Hooshmand, Rahmat-Allah
    Banejad, Mahdi
    Azimi, Mostafa
    UPB Scientific Bulletin, Series C: Electrical Engineering, 2009, 71 (04): : 49 - 62
  • [38] Under voltage accelerated protection of single source distribution systems
    Bo, ZQ
    Dong, XZ
    Caunce, BRJ
    Redfern, MA
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 2066 - 2071
  • [39] VOLTAGE SAG MITIGATION USING A NEW DIRECT CONTROL IN D-STATCOM FOR DISTRIBUTION SYSTEMS
    Hooshmand, Rahmat-Allah
    Banejad, Mahdi
    Azimi, Mostafa
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2009, 71 (04): : 49 - 62
  • [40] Coordinated Voltage Control Strategy for Voltage Regulators and Voltage Source Converters Integrated Distribution System
    Ahmed, Muhammad
    Bhattarai, Rojan
    Hossain, Sheikh Jakir
    Abdelrazek, Sherif
    Kamalasadan, Sukumar
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (04) : 4235 - 4246