Full-scale test behavior of cold-formed steel roof trusses

被引:16
|
作者
Wood, JV [1 ]
Dawe, JL [1 ]
机构
[1] Univ New Brunswick, Dept Civil Engn, Fredericton, NB E3B 5A3, Canada
关键词
D O I
10.1061/(ASCE)0733-9445(2006)132:4(616)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ten full-scale roof trusses fabricated from cold-formed steel channel sections were tested to ultimate capacity under concentrated panel point loading. As the test program moved forward and failure modes became manifest, various practical means of increasing truss capacity were investigated. While gusset plates at the heel connections in bearing were a significant factor in strength determination, local buckling of the top chord adjacent to the heel plates was the predominant failure mechanism. Trusses that experienced this local buckling failure exhibited postbuckling ductility, whereas failures at the connections in hearing were sudden. A truss was subjected to partial point loading to simulate the effect of a partial roof snow load and the experimental ultimate capacity substantiated the predicted capacity. A beam-column analysis of the top chord in the region where failure Occurred was performed in accordance with the requirements of the Canadian Standards Association CSA S136-01. The calculated nominal resistance was 12% conservative as compared to the experimental ultimate capacity of the truss. The trusses were sufficiently stiff to satisfy a deflection requirement of the span length (L) divided by 360.
引用
收藏
页码:616 / 623
页数:8
相关论文
共 50 条
  • [21] Development of Suitable Test Methods for the Screw Connections in Cold-Formed Steel Roof Battens
    Sivapathasundaram, Mayooran
    Mahendran, Mahen
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (06)
  • [22] Novel pin jointed moment connection for cold-formed steel trusses
    Mathison, Chris
    Roy, Krishanu
    Clifton, G. Charles
    Ahmadi, Amin
    Masood, Rehan
    Lim, James B. P.
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (05): : 453 - 467
  • [23] Novel pin-jointed connection for cold-formed steel trusses
    Mathieson, Chris
    Clifton, G. Charles
    Lim, James B. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 116 : 173 - 182
  • [24] BEHAVIOR OF EPOXY REPAIRED FULL-SCALE TIMBER TRUSSES
    AVENT, RR
    EMKIN, LZ
    SANDERS, PH
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (06): : 933 - 951
  • [25] Experimental Behavior of a Full-Scale Housing Section Built with Cold-Formed Steel Shear Wall Panels under Horizontal Monotonic and Cyclic Loading
    Moreno Cobo, Matilde
    Carazo Alvarez, Juan D.
    Mendez de Hasbun, Patricia
    Hasbun Hasbun, Jose Carlos
    Gomez Amador, Ana Maria
    Jimenez de Cisneros, Juan Jose
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [26] Dynamic and cyclic response of a full-scale 2-storey cold-formed steel structure with and without infill materials
    O. Senkardesler
    G. Goler
    S. Soyoz
    Bulletin of Earthquake Engineering, 2017, 15 : 3207 - 3226
  • [27] Shake table tests of a full-scale two-story sheathing-braced cold-formed steel building
    Fiorino, Luigi
    Macillo, Vincenzo
    Landolfo, Raffaele
    ENGINEERING STRUCTURES, 2017, 151 : 633 - 647
  • [28] Dynamic and cyclic response of a full-scale 2-storey cold-formed steel structure with and without infill materials
    Senkardesler, O.
    Goler, G.
    Soyoz, S.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (08) : 3207 - 3226
  • [29] Design of cold-formed CHS braces for steel roof structures
    Hassanein, M. F.
    Elchalakani, Mohamed
    Elkawas, A. A.
    THIN-WALLED STRUCTURES, 2017, 120 : 249 - 259
  • [30] Experimental and Numerical Study on the Effect of Heel Plate Length and Thickness on the Structural Integrity of Cold-formed Steel Roof Trusses
    Gan, Je Chenn
    Lim, Jee Hock
    Lim, Siong Kang
    Lin, Horng Sheng
    International Journal of Steel Structures, 2021, 21 (01): : 22 - 34