B-mode versus A-mode ultrasonographic measurements of mucosal thickness in vivo

被引:25
|
作者
Schulze, RKW [1 ]
Curic, D [1 ]
d'Hoedt, B [1 ]
机构
[1] Univ Mainz, Sch Dent, Dept Oral Surg, D-6500 Mainz, Germany
关键词
D O I
10.1067/moe.2002.119465
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to compare the measurement accuracy of A-mode and B-mode ultrasonographic assessments of palatal masticatory mucosal thickness in vivo. Study design. Thickness of palatal masticatory mucosa in the molar region of 50 volunteers was measured once with a B-mode ultrasound device (10 MHz) combined with a standoff for intraoral applications. At identical reading points thickness was also assessed with an A-mode device (5 replicates) and by needle probing for determination of true thickness. Results. On average true thickness ranged between 2.9 and 3.3 mm (95% confidence intervals; median, 3.1 mm). B-mode ultrasonography overestimated truth by 0.19 mm (median) and differed significantly from truth (P=.008), whereas A-mode ultrasonography slightly underestimated true thickness by -0.05 mm (median). Limits of agreement were wider for A-mode ultrasonography (2.00 mm) than for B-mode ultrasonography (0.88 mm). Conclusions. Because accuracy of 0.2 mm is acceptable for many clinical indications, B-mode and A-mode yield sufficient accuracy for measurements of mucosal thickness.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 50 条
  • [31] DOPPLER-MODE AND B-MODE ULTRASONOGRAPHY
    HENNERICI, M
    CURRENT OPINION IN NEUROLOGY AND NEUROSURGERY, 1988, 1 (06): : 990 - 995
  • [32] B-mode ultrasonographic characterization of carotid atherosclerotic plaques in symptomatic and asymptomatic patients
    Grogan, JK
    Shaalan, WE
    Cheng, HW
    Gewertz, B
    Desai, T
    Schwarze, G
    Glagov, S
    Lozanski, L
    Griffin, A
    Castilla, M
    Bassiouny, HS
    JOURNAL OF VASCULAR SURGERY, 2005, 42 (03) : 435 - 441
  • [33] B-mode and Contrast-Enhanced Ultrasonographic Findings in Canine Prostatic Disorders
    Russo, M.
    Vignoli, M.
    England, G. C. W.
    REPRODUCTION IN DOMESTIC ANIMALS, 2012, 47 : 238 - 242
  • [34] B-mode ultrasonographic investigations of morphological changes in endarterectomized carotid artery - Commentary
    Hoh, BL
    Ogilvy, CS
    SURGICAL NEUROLOGY, 2001, 55 (01): : 56 - 57
  • [36] First results of an ultrasonographic evaluation and characterization of mammary neoplasia in bitches using b-mode and color Doppler mode
    Feliciano, M. A. R.
    Vicente, W. R. R.
    Galera, P. D.
    Castro, M. B.
    REPRODUCTION IN DOMESTIC ANIMALS, 2010, 45 : 86 - 86
  • [37] In vivo moment arm determination using B-mode ultrasonography
    Ito, M
    Akima, H
    Fukunaga, T
    JOURNAL OF BIOMECHANICS, 2000, 33 (02) : 215 - 218
  • [38] In Vivo Noninvasive Temperature Measurement by B-Mode Ultrasound Imaging
    Pouch, Alison M.
    Cary, Theodore W.
    Schultz, Susan M.
    Sehgal, Chandra M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (11) : 1595 - 1606
  • [39] An Automatic Method for Measurements of Arterial Intima-Media Thickness Using Ultrasonic B-Mode Data
    Cinthio, Magnus
    Ahlgren, Asa Ryden
    Jansson, Tomas
    Nilsson, Tobias
    Lindstrom, Kjell
    Persson, Hans W.
    ACOUSTICAL IMAGING, VOL 31, 2012, 31 : 115 - 122
  • [40] A-Mode Ultrasound Reliability in Fat and Muscle Thickness Measurement
    Ribeiro, Guilherme
    de Aguiar, Rafael A.
    Penteado, Rafael
    Lisboa, Felipe D.
    Raimundo, Joao A. G.
    Loch, Thiago
    Meira, Angelo
    Turnes, Tiago
    Caputo, Fabrizio
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (06) : 1610 - 1617