B-mode versus A-mode ultrasonographic measurements of mucosal thickness in vivo

被引:25
|
作者
Schulze, RKW [1 ]
Curic, D [1 ]
d'Hoedt, B [1 ]
机构
[1] Univ Mainz, Sch Dent, Dept Oral Surg, D-6500 Mainz, Germany
关键词
D O I
10.1067/moe.2002.119465
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to compare the measurement accuracy of A-mode and B-mode ultrasonographic assessments of palatal masticatory mucosal thickness in vivo. Study design. Thickness of palatal masticatory mucosa in the molar region of 50 volunteers was measured once with a B-mode ultrasound device (10 MHz) combined with a standoff for intraoral applications. At identical reading points thickness was also assessed with an A-mode device (5 replicates) and by needle probing for determination of true thickness. Results. On average true thickness ranged between 2.9 and 3.3 mm (95% confidence intervals; median, 3.1 mm). B-mode ultrasonography overestimated truth by 0.19 mm (median) and differed significantly from truth (P=.008), whereas A-mode ultrasonography slightly underestimated true thickness by -0.05 mm (median). Limits of agreement were wider for A-mode ultrasonography (2.00 mm) than for B-mode ultrasonography (0.88 mm). Conclusions. Because accuracy of 0.2 mm is acceptable for many clinical indications, B-mode and A-mode yield sufficient accuracy for measurements of mucosal thickness.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 50 条
  • [1] A comparison of acute changes in muscle thickness between A-mode and B-mode ultrasound
    Kuehne, Tayla E.
    Yitzchaki, Noam
    Jessee, Matthew B.
    Graves, B. Sue
    Buckner, Samuel L.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (11)
  • [2] A-mode and B-mode ultrasound measurement of fat thickness: a cadaver validation study
    Wagner, Dale R.
    Thompson, Brennan J.
    Anderson, D. Andy
    Schwartz, Sarah
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2019, 73 (04) : 518 - 530
  • [3] A-mode and B-mode ultrasound measurement of fat thickness: a cadaver validation study
    Dale R. Wagner
    Brennan J. Thompson
    D. Andy Anderson
    Sarah Schwartz
    European Journal of Clinical Nutrition, 2019, 73 : 518 - 523
  • [4] ECHOENCEPHALOGRAPHY WITH SIMULTANEOUS A-MODE AND B-MODE DISPLAY
    KAZNER, E
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1970, 33 (05): : 718 - &
  • [5] A-mode and B-mode Ultrasound Measurement of Subcutaneous Fat Thickness: A Cadaver Analysis Validation Study
    Wagner, Dale R.
    Thompson, Brennan J.
    Anderson, D. Andy
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 257 - 257
  • [6] Exercise-induced Changes In Muscle Thickness As Measured By Both A-mode And B-mode Ultrasound
    Kuehne, Tayla E.
    Yitzchaki, Noam
    Graves, B. Sue
    Buckner, Samuel L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 336 - 336
  • [7] A-mode and B-mode Ultrasound Measurement of Subcutaneous Fat Thickness: A Cadaver Analysis Validation Study
    Wagner, Dale R.
    Thompson, Brennan J.
    Anderson, D. Andy
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 257 - 257
  • [8] COMPARISON OF A-MODE AND B-MODE ULTRASOUND FOR MEASUREMENT OF SUBCUTANEOUS FAT
    Wagner, Dale R.
    Teramoto, Masaru
    Judd, Trenton
    Gordon, Joshua
    Mcpherson, Casey
    Robison, Adrianna
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (04): : 944 - 951
  • [9] Comparison Of A-mode And B-mode Ultrasound For Measurement Of Subcutaneous Fat
    Wagner, Dale R.
    Judd, Trenton
    Gordon, Joshua
    McPherson, Casey
    Robison, Adrianna
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 158 - 158
  • [10] Agreement between A-mode and B-mode ultrasonography in the measurement of ocular distances
    Hamidzada, WA
    Osuobeni, EP
    VETERINARY RADIOLOGY & ULTRASOUND, 1999, 40 (05) : 502 - 507