A multicenter experience with novel implantable cardioverter defibrillator configurations in the pediatric and congenital heart disease population

被引:0
|
作者
Stephenson, EA
Batra, AS
Knilans, TK
Gow, RM
Gradaus, R
Balaji, S
Dubin, AM
Rhee, EK
Ro, PS
Thogersen, AM
Cecchin, F
Triedman, JK
Walsh, EP
Berul, CI
机构
[1] Hosp Sick Children, Div Cardiol, Toronto, ON M5G 1X8, Canada
[2] Harvard Univ, Sch Med, Childrens Hosp Boston, Boston, MA USA
[3] Indiana Univ, Sch Med, Indianapolis, IN USA
[4] Cincinnati Childrens Hosp Med Ctr, Cincinnati, OH USA
[5] Childrens Hosp Eastern Ontario, Ottawa, ON K1H 8L1, Canada
[6] Univ Klinikum Munster, Med Klin & Poliklin C, Munster, Germany
[7] Oregon Hlth & Sci Univ, Portland, OR USA
[8] Stanford Univ, Palo Alto, CA 94304 USA
[9] Washington Univ, Sch Med, St Louis, MO USA
[10] Columbus Childrens Hosp, Columbus, OH USA
[11] Rigshosp, Hjertectr, DK-2100 Copenhagen, Denmark
关键词
pediatric; implantable defibrillator; congenital heart disease;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Novel ICD Configurations in Pediatrics and Congenital Heart Disease. Introduction: In pediatric and congenital heart disease patients, transvenous ICD implantation may be limited secondary to patient size, venous, or cardiac anatomy. Epicardial patches require a thoracotomy, and may lead to a restrictive pericardial process. Because of these issues, we have explored novel ICD configurations. Methods: Retrospective review at 10 centers implanting ICDs without a transvenous shocking coil or epicardial patches. Results: Twenty-two patients underwent implant at a mean age of 8.9 years (range: 0.3-43.5), with a mean weight of 25.5 kg (range: 5.2-70). Diagnoses included complex CHD, intracardiac tumors, cardiomyopathy, idiopathic VT, LV noncompaction, and long QT syndrome. Three configurations were used: subcutaneous array, a transvenous design ICD lead placed on the epicardium, or a transvenous design ICD lead placed subcutaneously. Difficulties were found at implant in 8 patients: 4 had difficulty inducing VT/VF, and 4 had high DFTs. Over a mean follow-up of 2.2 years (range: 0.2-10.5), 7 patients had appropriate shocks. Inappropriate shocks occurred in 4 patients. System revisions were required in 7 patients: 2 generator changes (in 1 patient), 3 pace-sense lead replacement, 1 additional subcutaneous coil placement due to increased DFT, 1 upgrade to a transvenous system, and 1 revision to epicardial patch system. Conclusions: ICD implantation can be performed without epicardial patches or transvenous high-energy leads in this population, using individualized techniques. This will allow ICD use in patients who have intracardiac shunting or are deemed too small for transvenous ICD leads. The long-term outcome and possible complications are as yet unknown in this population, and they should be monitored closely with follow-up DFTs.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [1] A multicenter experience with novel implantable cardioverter defibrillator configurations in the pediatric and congenital heart disease population
    Stephenson, EA
    Batra, AS
    Knilans, TK
    Gradaus, R
    Balaji, S
    Dubin, AM
    Rhee, EK
    Thogersen, AM
    Triedman, JK
    Walsh, EP
    Cecchin, F
    Berul, CI
    CIRCULATION, 2003, 108 (17) : 494 - 494
  • [2] Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients
    Berul, Charles I.
    Van Hare, George F.
    Kertesz, Naomi J.
    Dubin, Anne M.
    Cecchin, Frank
    Collins, Kathryn K.
    Cannon, Bryan C.
    Alexander, Mark E.
    Triedman, John K.
    Walsh, Edward P.
    Friedman, Richard A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (17) : 1685 - 1691
  • [3] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR OUTCOMES IN PEDIATRIC AND CONGENITAL HEART DISEASE: IT'S COMPLICATED
    Dechert, Brynn
    Bradley, David J.
    Serwer, Gerald A.
    Dick, Macdonald, II
    LaPage, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A575 - A575
  • [4] Implantable Cardioverter Defibrillator Therapy in a Mixed Adult Congenital Heart Disease Population
    Joyce, E.
    O'Brien, C.
    Buckley, U.
    Keaney, J.
    Doran, E.
    Savage, R.
    Walsh, K.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S402 - S403
  • [5] Implantable Cardioverter Defibrillator Outcomes in Pediatric and Congenital Heart Disease: Time to System Revision
    Dechert, Brynn E.
    Bradley, David J.
    Serwer, Gerald A.
    Dick, Macdonald, II
    Lapage, Martin J.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (07): : 703 - 708
  • [6] Clinical Experience With the Subcutaneous Implantable Cardioverter-Defibrillator in Adults With Congenital Heart Disease
    Moore, Jeremy P.
    Mondesert, Blandine
    Lloyd, Michael S.
    Cook, Stephen C.
    Zaidi, Ali N.
    Pass, Robert H.
    John, Anitha S.
    Fish, Frank A.
    Shannon, Kevin M.
    Aboulhosn, Jamil A.
    Khairy, Paul
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (09):
  • [7] Implantable cardioverter-defibrillator therapy in congenital heart disease
    McLeod, Christopher J.
    Kapa, Suraj
    Asirvatham, Samuel J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (01) : 1 - 3
  • [8] Outcome of implantable cardioverter defibrillator therapy for congenital heart disease
    Uyeda, Tomomi
    Inoue, Kanki
    Sato, Junichiro
    Mizukami, Ayumi
    Yoshikawa, Tadahiro
    Wada, Naoki
    Ando, Makoto
    Takahashi, Yukihiro
    Umemura, Jun
    Park, In-Sam
    PEDIATRICS INTERNATIONAL, 2012, 54 (03) : 379 - 382
  • [9] Experience with implantable cardioverter-defibrillator therapy in grown-ups with congenital heart disease
    Tomaske, Maren
    Bauersfeld, Urs
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 : S35 - S37
  • [10] Eligibility for subcutaneous implantable cardioverter-defibrillator in congenital heart disease
    Wang, Linda
    Javadekar, Neeraj
    Rajagopalan, Ananya
    Rogovoy, Nichole M.
    Haq, Kazi T.
    Broberg, Craig S.
    Tereshchenko, Larisa G.
    HEART RHYTHM, 2020, 17 (05) : 860 - 869