Atmospheric CO2, δ(O2/N2) and δ13CO2 measurements at Jungfraujoch, Switzerland: results from a flask sampling intercomparison program

被引:10
|
作者
van der Laan-Luijkx, I. T. [1 ,2 ,3 ]
van der Laan, S. [1 ,2 ]
Uglietti, C. [1 ,2 ]
Schibig, M. F. [1 ,2 ]
Neubert, R. E. M. [3 ]
Meijer, H. A. J. [3 ]
Brand, W. A. [4 ]
Jordan, A. [4 ]
Richter, J. M. [4 ]
Rothe, M. [4 ]
Leuenberger, M. C. [1 ,2 ]
机构
[1] Univ Bern, Inst Phys, Bern, Switzerland
[2] Univ Bern, Oeschger Ctr Climate Change Res, Bern, Switzerland
[3] Univ Groningen, Ctr Isotope Res, Groningen, Netherlands
[4] Max Planck Inst Biogeochem, D-07745 Jena, Germany
关键词
ISOTOPE-RATIO; GREENHOUSE GASES; CARBON SINKS; AIR SAMPLES; TALL TOWER; OXYGEN; O-2; O-2/N-2; STATION; N2O;
D O I
10.5194/amt-6-1805-2013
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
We present results from an intercomparison program of CO2, delta(O-2/N-2) and delta(CO2)-C-13 measurements from atmospheric flask samples. Flask samples are collected on a biweekly basis at the High Altitude Research Station Jungfraujoch in Switzerland for three European laboratories: the University of Bern, Switzerland, the University of Groningen, the Netherlands and the Max Planck Institute for Biogeochemistry in Jena, Germany. Almost 4 years of measurements of CO2, delta(O-2/N-2) and delta(CO2)-C-13 are compared in this paper to assess the measurement compatibility of the three laboratories. While the average difference for the CO2 measurements between the laboratories in Bern and Jena meets the required compatibility goal as defined by the World Meteorological Organization, the standard deviation of the average differences between all laboratories is not within the required goal. However, the obtained annual trend and seasonalities are the same within their estimated uncertainties. For delta(O-2/N-2) significant differences are observed between the three laboratories. The comparison for delta(CO2)-C-13 yields the least compatible results and the required goals are not met between the three laboratories. Our study shows the importance of regular intercomparison exercises to identify potential biases between laboratories and the need to improve the quality of atmospheric measurements.
引用
收藏
页码:1805 / 1815
页数:11
相关论文
共 50 条
  • [41] INTERCOMPARISON OF CO2 MEASUREMENTS
    POISSON, A
    CULKIN, F
    RIDOUT, P
    DEEP-SEA RESEARCH PART A-OCEANOGRAPHIC RESEARCH PAPERS, 1990, 37 (10): : 1647 - 1650
  • [42] Terrestrial biospheric and oceanic CO2 uptakes estimated from long-term measurements of atmospheric CO2 mole fraction, 13C, and (O2/N2) at Ny-Ålesund, Svalbard
    Goto, Daisuke
    Morimoto, Shinji
    Ishidoya, Shigeyuki
    Aoki, Shuji
    Nakazawa, Takakiyo
    JOURNAL OF GEOPHYSICAL RESEARCH-BIOGEOSCIENCES, 2017, 122 (05) : 1192 - 1202
  • [43] RETARDING POTENTIAL MEASUREMENTS OF ELECTRONS PHOTOEMITTED BY N2, CO, + O2
    SCHOEN, RI
    JOURNAL OF CHEMICAL PHYSICS, 1964, 40 (07): : 1830 - &
  • [44] Streamer propagation in CO2 and N2/CO2 mixtures at atmospheric pressure
    Omori, Kento
    Ono, Ryo
    Komuro, Atsushi
    Plasma Sources Science and Technology, 2024, 33 (12)
  • [45] DISSOCIATIVE IONIZATION OF N2, O2, H2O, CO2 AND ETHANE
    EHRHARDT, H
    KRESLING, A
    ZEITSCHRIFT FUR NATURFORSCHUNG PART A-ASTROPHYSIK PHYSIK UND PHYSIKALISCHE CHEMIE, 1967, A 22 (12): : 2036 - &
  • [46] An experimental study and numerical modeling of combusting two coal chars in a drop-tube reactor: A comparison between N2/O2, CO2/O2, and N2/CO2/O2 atmospheres
    Tolvanen, Henrik
    Raiko, Risto
    FUEL, 2014, 124 : 190 - 201
  • [47] Emission characteristics of coal combustion in different O2/N2, O2/CO2 and O2/RFG atmosphere
    Chen, Jyh-Cherng
    Liu, Zhen-Shu
    Huang, Jian-Sheng
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 142 (1-2) : 266 - 271
  • [48] Laser diagnostics of pulverized coal combustion in O2/N2 and O2/CO2 conditions: velocity and scalar field measurements
    Saravanan Balusamy
    M. Mustafa Kamal
    Steven M. Lowe
    Bo Tian
    Yi Gao
    Simone Hochgreb
    Experiments in Fluids, 2015, 56
  • [49] Facilitated transport membrane with functionalized ionic liquid carriers for CO2/N2, CO2/O2, and CO2/air separations
    Lee, Yun-Yang
    Wickramasinghe, Nalinda P.
    Dikki, Ruth
    Jan, Darrell L.
    Gurkan, Burcu
    NANOSCALE, 2022, 14 (35) : 12638 - 12650
  • [50] Precision refractive index measurements of air, N2, O2, Ar, and CO2 with a frequency comb
    Zhang, J.
    Lu, Z. H.
    Wang, L. J.
    APPLIED OPTICS, 2008, 47 (17) : 3143 - 3151