Unenhanced breast magnetic resonance imaging: detection of breast cancer

被引:1
|
作者
Belli, P. [1 ]
Bufi, E. [1 ]
Bonatesta, A. [1 ]
Patrolecco, F. [1 ]
Padovano, F. [1 ]
Giuliani, M. [1 ]
Rinaldi, P. [1 ]
Bonomo, L. [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Dept Radiol, Policlin A Gemelli, Rome, Italy
关键词
Unenhanced MRI; Breast cancer; DWI; STIR; APPARENT DIFFUSION-COEFFICIENT; LESION CHARACTERIZATION; PROGNOSTIC-FACTORS; T2-WEIGHTED TSE; WEIGHTED MRI; DIFFERENTIATION; TUMORS; BENIGN; CHOICE; VALUES;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: To evaluate the diagnostic performance of unenhanced MRI (UE-MRI) for malignant breast lesions and its reproducibility. PATIENTS AND METHODS: We retrospectively included 118 patients who had breast MRI. DWI and STIR images were read in combination and referred to as UE-MRI; the presence or absence of the malignant lesion was noted by two observers. Their results were compared with those of final histopathology or with a two-year negative follow-up for diagnostic performance assessment; ROC curves were built. Diagnostic performance was stratified according to lesion site and size. Interobserver agreement was evaluated through the Cohen's k statistic. RESULTS: Specificity of STIR and DWI was 99.3% and 95.7% for Reader 1; 99.3% and 96.4% for Reader 2. Sensitivity was 76.5% and 76.5% for Reader 1; 77.5% and 77.6% for Reader 2. The ROC AUC (Reader 1) was 0.869 and 0.844 for STIR and DWI, respectively (p<0.001 both); for Reader 2, values were 0.874 and 0.853 respectively (p<0.001 both). Lesion dimension <= 10 mm was associated with lower AUC values. Lesion site didn't influence the diagnostic performance. Interobserver agreement was very good for STIR and DWI (k=0.887, p<0.001, and k=0.867, p<0.001). DISCUSSION: UE-MRI has a good overall diagnostic performance in the detection of breast cancer and a very good specificity for both STIR and DWI sequences. We observed reduced diagnostic performance for lesions <= 10 mm in size. Lesion's site isn't associated with a significantly decreased diagnostic performance of UE-MRI. There's a good interobserver agreement for both sequences (STIR and DWI). CONCLUSIONS: UE-MRI may be employed in patients with contraindication to gadolinium. It has considerable specificity and positive predictive value and good reproducibility.
引用
收藏
页码:4220 / 4229
页数:10
相关论文
共 50 条
  • [41] The role of magnetic resonance imaging in early breast cancer
    Skandarajah, Anita R.
    Mann, G. Bruce
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2012, 8 (01) : 24 - 30
  • [42] The role of magnetic resonance imaging in breast cancer research
    Gilbert, FJ
    BRITISH JOURNAL OF CANCER, 2001, 85 : 9 - 9
  • [44] Magnetic resonance Imaging of breast cancer angiogenesis: A review
    Furman-Haran, E
    Kelcz, F
    Degani, H
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2002, 21 (03): : 47 - 54
  • [45] Comparative Effectiveness of Magnetic Resonance Imaging in Breast Cancer
    Henteleff, Harry J. A.
    Hunt, Kelly K.
    Quan, May Lynn
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2012, 215 (06) : 894 - 894
  • [46] Magnetic Resonance Imaging of the Breast for Cancer Diagnosis and Staging
    Monticciolo, Debra L.
    SEMINARS IN ULTRASOUND CT AND MRI, 2011, 32 (04) : 319 - 330
  • [47] Utilization of magnetic resonance imaging in breast cancer screening
    Lin, D.
    Moy, L.
    Axelrod, D.
    Smith, J.
    CURRENT ONCOLOGY, 2015, 22 (05) : E332 - E335
  • [48] Magnetic resonance imaging: Advanced applications in breast cancer
    Rahbar H.
    Kitsch A.E.
    Partridge S.C.
    Current Radiology Reports, 4 (3)
  • [49] Role of magnetic resonance imaging in breast cancer management
    Radhakrishna, Selvi
    Agarwal, S.
    Parikh, Purvish M.
    Kaur, K.
    Panwar, Shikha
    Sharma, Shelly
    Dey, Ashish
    Saxena, K. K.
    Chandra, Madhavi
    Sud, Seema
    SOUTH ASIAN JOURNAL OF CANCER, 2018, 7 (02) : 69 - 71
  • [50] Magnetic resonance imaging of the breast
    Balu-Maestro, C
    JOURNAL DE RADIOLOGIE, 2001, 82 (01): : 17 - 26