Miniaturized atomic fountain optical table

被引:3
|
作者
Crane, Scott [1 ]
Peil, Steven [1 ]
Ekstrom, Chrisopher R. [1 ]
机构
[1] USN Observ, Time Serv Dept, Clock Dev Div, Washington, DC 20392 USA
关键词
D O I
10.1109/FREQ.2005.1573948
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using commercially available components at a cost comparable to conventional free-space optics, we have bunt a miniaturized version of the optical setup for an atomic fountain that fits onto a 40 cm by 55 cm rack-mounted breadboard. With this system, light from an input fiber is split into ten fiber-coupled output beams: two frequency-tunable sets of three collection/launching beams, beams for repumping and detection, and two diagnostic beams. The output fibers deliver the laser light to integrated optical couplers that bolt directly to the atomic-fountain vacuum chamber [1]. Approximately 30% of the light from the input fiber is available for the experiment.
引用
收藏
页码:301 / 303
页数:3
相关论文
共 50 条
  • [31] Progress on the construction of an atomic cesium fountain at NIM
    Li, TC
    Li, MS
    Huang, BY
    Qian, J
    Lin, PW
    PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2001, : 101 - 104
  • [32] Fold optics path:an improvement for an atomic fountain
    魏荣
    周子超
    史春艳
    赵剑波
    李唐
    王育竹
    Chinese Physics B, 2011, (08) : 525 - 529
  • [33] Atomic clock with cesium fountain frequency standard
    Bauch, A
    PTB-MITTEILUNGEN, 1998, 108 (01): : 3 - 18
  • [34] In situ measurement of magneto-optical non-orthogonality in miniaturized atomic magnetometer
    Li, Renjie
    Liu, Ying
    Cao, Qian
    Li, Jiajie
    Zhai, Yueyang
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 360
  • [35] Experimental study of a miniaturized calcium atomic beam tube for small optical frequency standard
    Chen, Haijun
    Liu, Zhongzheng
    Xiao, Shunlu
    Shang, Haosen
    Zhang, Shengnan
    Chen, Jingbiao
    2017 JOINT CONFERENCE OF THE EUROPEAN FREQUENCY AND TIME FORUM AND IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFC), 2017, : 737 - 739
  • [36] Residual frequency drift in an atomic fountain clock
    Du, Yuanbo
    Wei, Rong
    Dong, Richang
    Zou, Fan
    Lin, Jinda
    Wang, Wenli
    Wang, Yuzhu
    CHINESE OPTICS LETTERS, 2015, 13 (09)
  • [37] The Brazilian atomic fountain primary frequency standard
    Bebeachibuli, A.
    Alves, R. F.
    Muller, S. T.
    Bagnato, V. S.
    Magalhaes, D. V.
    PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXPOSITION, VOLS 1 AND 2, 2006, : 291 - +
  • [38] Development of a cesium atomic fountain frequency standard
    Kwon, TY
    Lee, HS
    Yang, SH
    Park, SE
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 263 - 266
  • [39] Work towards an atomic fountain clock at Peking
    Li, YM
    Hou, JD
    Fu, JX
    Chen, XZ
    Yang, DH
    Wang, YQ
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, : 28 - 31
  • [40] Recent improvements on the atomic fountain clock at SIOM
    杜远博
    魏荣
    董日昌
    邹凡
    王育竹
    Chinese Physics B, 2015, (07) : 191 - 194