Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system

被引:12
|
作者
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
Pinto, APMMO [1 ]
机构
[1] Fac Farm, CEQUP, Dept Quim Fis, P-4050 Porto, Portugal
来源
关键词
D O I
10.1007/s002160051348
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection set-up based on potentiometric detection and gas diffusion device for the determination of total nitrogen in food is described. The detection system consisted of two ammonium-sensitive electrodes placed sequentially and each alternately operating as reference electrode. Tubular electrodes without an inner reference solution were prepared with a PVC membrane composed of nonactin in Tris (2-ethylhexyl) phosphate and potassium tetrakis (4-chlorophenyl) berate to reduce the membrane resistance. The food sample digests were inserted into the system, and the ammonium present was converted into ammonia gas. The gas diffused through a gas-permeable membrane to a buffer acceptor stream with a pH that ensured transformation to the ammonium cation, which was potentiometrically detected. Good agreement between FIA results and those provided by the reference procedure was obtained, with relative deviation errors below 5%. Using the proposed system, low reagent consumption is possible, a sampling rate of about 30 samples/h was achieved, as well as a good reproducibility for consecutive injections of the same sample (variation coefficient < 2%).
引用
收藏
页码:353 / 357
页数:5
相关论文
共 50 条
  • [1] Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system
    José L. F. C. Lima
    M. C. B. S. M. Montenegro
    Ana P. M. M. O. Pinto
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 353 - 357
  • [2] Determination of nitrate in carbon black by flow injection analysis (FIA) with potentiometric detection
    Canal, IG
    Lima, JLFC
    Montenegro, MCBSM
    PrezOlmos, R
    ANALUSIS, 1997, 25 (02) : 32 - 35
  • [3] Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit
    Ferreira, AMR
    Lima, JLFC
    Rangel, AOSS
    AUSTRALIAN JOURNAL OF SOIL RESEARCH, 1996, 34 (04): : 503 - 510
  • [4] Determination of orciprenaline using a flow injection analysis system with sequential potentiometric and spectrophotometric detection
    El Nashar, Rasha Mohamed
    ANALYTICAL LETTERS, 2008, 41 (06) : 949 - 964
  • [5] Determination of chloride by multisyringe flow injection analysis and sequential injection analysis with potentiometric detection
    Andrade-Eiroa, A
    Erustes, JA
    Forteza, R
    Cerdá, V
    Lima, JLFC
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 25 - 33
  • [6] Flow injection system with potentiometric detection for the determination of urea content in milks
    Lima, JLFC
    Delerue-Matos, C
    Vaz, MCVF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (04) : 1386 - 1389
  • [7] Enzymatic determination of choline in milk using a FIA system with potentiometric detection
    Lima, JLFC
    Delerue-Matos, C
    Vaz, MCVF
    ANALYST, 2000, 125 (07) : 1281 - 1284
  • [8] An enzymatic amplification Flow Injection Analysis (FIA) system for the sensitive determination of phenol
    Fuhrmann, B
    Spohn, U
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8): : 895 - 902
  • [9] Determination of Nitrate in Leafy Vegetables by Flow Injection Analysis with Potentiometric Detection
    Andac, Muberra
    Eren, Hilal
    Coldur, Fatih
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2011, 19 (04) : 457 - 462
  • [10] Determination of Dipyrone in Pharmaceutical Products by Flow Injection Analysis with Potentiometric Detection
    Jackson S. Albuquerque
    Valdinete L. Silva
    Fernando Lima
    Alberto N. Araújo
    Maria Conceição B. S. M. Montenegro
    Analytical Sciences, 2003, 19 : 691 - 694