Numerical Simulation on Water Mist Fire Suppression System Operation in Typical Environment

被引:0
|
作者
Liu, Peng [1 ]
机构
[1] Harbin Univ Commerce, Sch Energy & Civil Engn, Harbin 150076, Heilongjiang, Peoples R China
关键词
water mist; simulation; fire scenario;
D O I
10.4028/www.scientific.net/AMR.732-733.491
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Water mist fire suppression system is widely used in many places, for its little damage and greatly reduces the cost of extinguishing fire. But because of the intricate extinguishing mechanism of water mist, it is difficult to design an optimal water mist fire suppression system in a typical place. With the rapid development of computer technology, computational fluid dynamics (CFD) has already been proved to be a useful and powerful tool in fire safety science. Fire Dynamics Simulator (FDS) is used to simulated the interaction of water mist and fire in a typical fire scenario in this paper. Two design schemes of water mist system are compared to prove which one is better. Through simulated by FDS on these two cases, the water mist system with 4 sprinklers is suited in the restroom.
引用
收藏
页码:491 / 494
页数:4
相关论文
共 50 条
  • [31] Catastrophe analysis of the water mist fire suppression process
    School of Astronautics, Beijing University of Aeronautics and Astronautics, Beijing 100191, China
    Beijing Hangkong Hangtian Daxue Xuebao, 3 (340-343):
  • [32] Effectiveness of Swirl Water Mist Nozzles for Fire Suppression
    Kraus-Namrozy, Natalia
    Brzezinska, Dorota
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (23)
  • [33] Fire suppression mechanisms of solid fires with water mist
    State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026, China
    Ranshao Kexue Yu Jishu, 2007, 1 (40-44):
  • [34] A Review of Additives for Water Mist Fire Suppression Systems
    Robinet, Antonin
    Chetehouna, Khaled
    FIRE TECHNOLOGY, 2024, 60 (05) : 2923 - 2961
  • [35] Suppression of pool fire in a large enclosure with water mist
    Lal, Suresh
    Gupta, Meenakshi
    Kushari, A.
    Kapoor, J. C.
    Maji, S.
    INTERNATIONAL JOURNAL OF SPRAY AND COMBUSTION DYNAMICS, 2013, 5 (03) : 181 - 199
  • [36] Fire suppression performance of water mist systems with additives
    Kim, AK
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL II, PT A AND B, 2000, 2 : 561 - 566
  • [37] Fire tests for water mist fire suppression systems in road tunnels
    Leucker, R.
    Leismann, F.
    UNDERGROUND - THE WAY TO THE FUTURE, 2013, : 366 - 375
  • [38] Influence of additives on the fire suppression performance of water mist
    Jiang, Juncheng, 1600, China University of Mining and Technology (43):
  • [39] Improving fire suppression of water mist by chemical additives
    Chow, W. K.
    Jiang, Z.
    Li, S. F.
    Han, D. L.
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2007, 46 (01) : 51 - 60
  • [40] Experimental and numerical study on kerosene pool fire suppression with water mist in a standard confined compartment
    Zheng, LG
    Yu, MG
    Xing, ZF
    Liu, ZC
    Zuo, QL
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1187 - 1192