Direct determination of bromacil and diuron residues in environmental water samples by coupled-column liquid chromatography and large-volume injection

被引:14
|
作者
Sancho, JV
Hidalgo, C
Hernandez, F
机构
[1] Analytical Chemistry, Experimental Sciences Department, University Jaume I, 12080 Castelló
关键词
water analysis; pesticides; environmental analysis; large-volume injections; bromacil; diuron;
D O I
10.1016/S0021-9673(96)00827-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid procedure For the determination of two herbicides in environmental water samples is described. The method makes use of the potential of coupled-column liquid chromatography for the trace determination of polar compounds by direct large-volume injection of aqueous samples. With direct injection of 2000-mu 1 samples, detection limits dawn to 0.1 mu g/l and an analysis time of about 10 min can be achieved, rendering an overall procedure with a throughput of 50 samples per day. Drinking and surface water samples spiked at levels between 0.2 and 1 mu g/l yielded average recoveries between 83-107% (n=5) with relative standard deviations between 3-8%. The calibration graphs are linear over at least three orders of magnitude.
引用
收藏
页码:322 / 326
页数:5
相关论文