Screening of renal artery stenosis: Assessment with magnetic resonance angiography at 1.0 T

被引:9
|
作者
Laissy, JP [1 ]
Benyounes, M [1 ]
Limot, O [1 ]
Cinqualbre, A [1 ]
Benamer, H [1 ]
Kenouch, S [1 ]
HenryFeugeas, MC [1 ]
Falise, B [1 ]
Chillon, S [1 ]
Valere, PE [1 ]
SchoumanClaeys, E [1 ]
机构
[1] HOP BICHAT, DEPT RADIOL, F-75877 PARIS 18, FRANCE
关键词
renal arteries; MR studies; stenosis or obstruction; magnetic resonance (MR); comparative studies; vascular studies;
D O I
10.1016/S0730-725X(96)00097-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The results of MR angiography at 1.0 T with digital intraarterial angiography in the screening of patients with suspected renal hypertension were compared. In the first phase of the study, 10 volunteers underwent examination with both two-dimensional (2D) with traveling saturation time-of-flight (TOF) magnetic resonance angiography (MRA) with various parameters to develop a protocol for evaluation of the renal arteries, In the second phase, 36 patients with suspected renovascular hypertension underwent both 2D TOF MRA and intraarterial digital angiography to evaluate the clinical value of MRA. The degree of stenosis was graded with a two-point scale, In volunteers, using 2D acquisitions, C/N ratios indicated the best flip angle as being 55 degrees (p = .02), MRA showed 100% (70/70) of all main arteries and 86% (6/7) of all accessory renal arteries seen on angiography, MRA had a sensitivity of 94% (15/16) and a specificity of 98% (60/61) for detection of stenoses of greater than 50% present in 14 patients. 2D-TOF MRA at 1.0 T shows promise in the noninvasive diagnosis of patients with suspected renovascular hypertension. Copyright (C) 1996 Elsevier Science Inc.
引用
收藏
页码:1033 / 1041
页数:9
相关论文
共 50 条
  • [41] Respective value of renal scintigraphy, intrarenal Doppler sonography and magnetic resonance angiography for the detection of renal artery stenosis
    Soulez, GP
    Oliva, VL
    Nicolet, V
    Froment, D
    Courteau, M
    Therasse, E
    RADIOLOGY, 1999, 213P : 271 - 271
  • [42] Noncontrast enhanced magnetic resonance angiography is comparable to color Doppler ultrasound for screening for renal artery stenosis, but is faster and shows more segments
    Saejeung, Siripat
    Sasiwimolphan, Kawalee
    Vajragupta, Laddawan
    Wangsuphachart, Somjai
    Tumkosit, Monravee
    ASIAN BIOMEDICINE, 2015, 9 (03) : 373 - 378
  • [43] Usefulness of magnetic resonance angiography in the screening of renal artery stenosis in hypertensive patients: proposition of a diagnostic algorithm: a study on 245 patients.
    Biausque, F.
    Willoteaux, S.
    Beregi, J. P.
    Devos, P.
    Deklunder, G.
    Mounier-Vehier, C.
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2006, 99 (7-8): : 705 - 711
  • [44] Limitations of Angiography for the Assessment of Renal Artery Stenosis and Treatment Implications
    Cam, Akin
    Chhatriwalla, Adnan K.
    Kapadia, Samir R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (01) : 38 - 42
  • [45] Functional magnetic resonance imaging in renal artery stenosis
    Schoenberg, SO
    Rieger, JR
    Michaely, HJ
    Rupprecht, H
    Samtleben, W
    Reiser, MF
    ABDOMINAL IMAGING, 2006, 31 (02): : 200 - 212
  • [46] Magnetic resonance in the quantification of renal artery stenosis degree
    Saba, L.
    Sanfilippo, R.
    Mallarini, G.
    JOURNAL OF HYPERTENSION, 2008, 26 : S286 - S286
  • [47] Functional magnetic resonance imaging in renal artery stenosis
    S. O. Schoenberg
    J. R. Rieger
    H. J. Michaely
    H. Rupprecht
    W. Samtleben
    M. F. Reiser
    Abdominal Imaging, 2006, 31 : 200 - 212
  • [48] Quantitative assessment of carotid artery stenosis: Comparison of contrast-enhanced magnetic resonance angiography and digital subtraction angiography
    Wintersperger, BJ
    Huber, AM
    Holzknecht, NG
    Helmberger, TK
    Billing, A
    Reiser, MF
    RADIOLOGY, 2001, 221 : 298 - 298
  • [49] RENAL ARTERY STENOSIS: THE COMPARISON OF THE DOPPLER USG, CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY AND SELECTIVE RENAL ARTERIOGRAPHY
    Turgutalp, Kenan
    Kiykim, Ahmet
    Helvaci, Ilter
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 356 - 356
  • [50] Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography
    Nederkoorn, PJ
    Elgersma, OEH
    Mali, WPTM
    Eikelboom, BC
    Kappelle, LJ
    van der Graaf, Y
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (04) : 806 - 813