Cementless Revision for Infected Hip Arthroplasty: an 8.6 Years Follow-up

被引:8
|
作者
Li, Peng [1 ]
Hou, Ming [1 ]
Zhu, Zhi-qi [1 ]
Shi, Zhan-jun [2 ]
机构
[1] Longgang Dist Peoples Hosp Shenzhen, Dept Orthopaed Surg, Shenzhen, Peoples R China
[2] Southern Med Univ, Dept Orthopaed Surg, Nanfang Hosp, Guangzhou 510515, Guangdong, Peoples R China
关键词
Arthroplasty; Hip; Infection; ONE-STAGE REVISION; REPLACEMENT; STEMS;
D O I
10.1111/os.12159
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To investigate cementless revision for postoperative infection after total hip arthroplasty (THA). Methods: From November 1997 to December 2009, 10 patients (10 hips; four males, six females) of mean age 58 years (36-73 years) with infection after THA were treated. Six of the 10 hips underwent revision total hip arthroplasty, two only received new acetabular components and two underwent stem revision. One-stage revision was performed in six cases and two-stage revision in four. Consecutive radiographs were compared to evaluate component conditions. Harris hip scores were determined before surgery and at final follow-up. Erythrocyte sedimentation rate and C-reactive protein were assessed. Results: All patients were followed up for a mean duration of 8.6 years (6.5-15.6 years). The mean Harris hip score improved from 35 (18-63) points preoperatively to 89 (60-99) points at final follow-up. No re-infection occurred. Femoral component exsertion was occurred in one asymptomatic patient. Hip joint pain resolved in seven cases; three patients had mild pain when walking long distances. At final follow-up, six patients still had slight limps. Heterotopic ossification developed in two hips. Mean polyethylene liner wear was 0.08 mm per year at final follow-up. Deep vein phlebothrombosis and nerve injury did not occur. Conclusion: One-or two-stage revisions using cementless prosthesis can produce satisfactory clinical outcomes in patients with infection after THA. Whether the original prosthesis can be partially retained when attached tightly to the femur or acetabular bone needs further investigation.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [41] TOTAL HIP-ARTHROPLASTY IN PATIENTS WITH AVASCULAR NECROSIS OF THE HIP - FOLLOW-UP OBSERVATIONS ON CEMENTLESS AND CEMENTED OPERATIONS
    KATZ, RL
    BOURNE, RB
    RORABECK, CH
    MCGEE, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (281) : 145 - 151
  • [42] Modular cementless cup for total hip arthroplasty: Results at 4-year follow-up
    Bistolfi A.
    Massazza G.
    Rosso F.
    Ventura S.
    Lagalla F.
    Crova M.
    MUSCULOSKELETAL SURGERY, 2012, 96 (2) : 89 - 94
  • [43] Primary cementless total hip arthroplasty in octogenarians - Two to eleven-year follow-up
    Keisu, KS
    Orozco, F
    Sharkey, PF
    Hozack, WJ
    Rothman, RH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (03): : 359 - 363
  • [44] Titanium cage reconstruction of acetabular defects in revision hip arthroplasty results in favourable outcomes: up to 17 years follow-up
    Akel, Ibrahim
    Caglar, Omur
    Tokgozoglu, A. Mazhar
    Atilla, Bulent
    HIP INTERNATIONAL, 2020, 30 (05) : 617 - 621
  • [45] Total Hip Arthroplasty with Use of the Cementless Zweymuller Alloclassic System A Concise Follow-up, at a Minimum of 25 Years, of a Previous Report
    Cruz-Pardos, Ana
    Garcia-Rey, Eduardo
    Garcia-Cimbrelo, Eduardo
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (22): : 1927 - 1931
  • [46] Cementless Total Hip Arthroplasty with the Rectangular Titanium Zweymuller Stem: A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports
    Pieler-Bruha, E.
    JOURNAL FUR MINERALSTOFFWECHSEL, 2012, 19 (04): : 191 - 191
  • [47] Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem -: A concise follow-up, at a minimum of fifteen years, of a previous report
    Gruebl, Alexander
    Chiari, Catharina
    Giurea, Alexander
    Gruber, Martin
    Kaider, Alexandra
    Marker, Martina
    Zehetgruber, Harald
    Gottsauner-Wolf, Florian
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10): : 2210 - 2215
  • [48] Cementless Total Hip Arthroplasty with the Rectangular Titanium Zweymuller Stem A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports
    Kolb, Alexander
    Gruebl, Alexander
    Schneckener, Charlotte-Dorothe
    Chiari, Catharina
    Kaider, Alexandra
    Lass, Richard
    Windhager, Reinhard
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18): : 1681 - 1684
  • [49] Revision total hip arthroplasty with cement after cup arthroplasty - Long-term follow-up
    Ash, SA
    Callaghan, JJ
    Johnston, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (01): : 87 - 93
  • [50] Revision with Cementless Acetabular Components A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports
    Trumm, Bryan N.
    Callaghan, John J.
    Liu, Steve S.
    Goetz, Devon D.
    Johnston, Richard C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (21): : 2001 - 2004