Software-based assessment of postoperative rotation of toric intraocular lens

被引:32
|
作者
Shah, Gauri D. [1 ]
Praveen, Mamidipudi R. [1 ]
Vasavada, Abhay R. [1 ]
Rampal, Naveen V. [2 ]
Vasavada, Viraj A. [1 ]
Asnani, Priyadarshi K. [1 ]
Pandita, Deepa. K. [1 ]
机构
[1] Raghudeep Eye Clin, Iladevi Cataract & IOL Res Ctr, Ahmadabad 380052, Gujarat, India
[2] Indian Inst Technol Delhi, New Delhi, India
来源
关键词
CATARACT PATIENTS; ASTIGMATISM CORRECTION; AXIAL ORIENTATION; STABILITY; EYES; IMPLANTATION;
D O I
10.1016/j.jcrs.2008.10.057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A specially designed grid and software used to assess the postoperative rotation of a toric intraocular lens (IOL) are described. Postoperatively, a digital retroillumination image of the patient is taken and this image is superimposed on the grid. The software determines the center of the IOL. A prominent episcleral vessel is identified, and the axis of the toric IOL and the episcleral vessel are documented using the grid. These values act as references for aligning the images taken during the follow-up period.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 50 条
  • [21] Toric Intraocular Lens Calculations
    Savini, Giacomo
    Hoffer, Kenneth J.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 947 - 948
  • [22] Comparison of Postoperative Axial Rotation of the Toric Intraocular Lens in Cataract Surgery Combined with Vitrectomy versus Cataract Surgery Alone
    Mito, Tsuyoshi
    Ishida, Hidetoshi
    Seki, Yusuke
    Shirayama, Takuro
    Ukai, Yuki
    Sasaki, Hiroshi
    OPHTHALMOLOGICA, 2024, 247 (04) : 224 - 230
  • [23] Toric intraocular lens report
    Grabow, HB
    ANNALS OF OPHTHALMOLOGY-GLAUCOMA, 1997, 29 (03): : 161 - 163
  • [24] Rotation of a toric intraocular lens from neodymium:YAG laser posterior capsulotomy
    Kaindlstorfer, Clemens
    Kneifl, Mario
    Reinelt, Peter
    Schoenherr, Ulrich
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04): : 510 - 511
  • [25] Transscleral fixation of a supplementary toric intraocular lens to prevent rotation in a pseudophakic patient
    McGrath, Lindsay A.
    Lee, Graham A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (01): : 134 - 138
  • [26] Accuracy and precision of a new system for measuring toric intraocular lens axis rotation
    Sanders, Donald R.
    Sarver, Edwin J.
    Cooke, David L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (08): : 1190 - 1195
  • [27] Association between axial length and toric intraocular lens rotation according to an online toric back-calculator
    Jennifer L.Patnaik
    Malik Y.Kahook
    John P.Berdahl
    David R.Hardten
    Brandie D.Wagner
    Leonard K.Seibold
    Brent A.Kramer
    International Journal of Ophthalmology, 2022, 15 (03) : 420 - 425
  • [28] Association between axial length and toric intraocular lens rotation according to an online toric back-calculator
    Patnaik, Jennifer L.
    Kahook, Malik, V
    Berdahl, John P.
    Hardten, David R.
    Wagner, Brandie D.
    Seibold, Leonard K.
    Kramer, Brent A.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (03) : 420 - 425
  • [29] Toric intraocular lens rotation to optimize refractive outcome despite appropriate intraoperative positioning
    Lockwood, James C.
    Randleman, J. Bradley
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04): : 878 - 883
  • [30] Toric intraocular lens in asymmetric astigmatism
    Sergio Kwitko
    Samara Barbara Marafon
    Andressa Prestes Stolz
    International Ophthalmology, 2020, 40 : 1291 - 1298