Maintenance of a calibration model for near infrared spectrometry by a combined principal component analysis-partial least squares approach

被引:10
|
作者
Setarehdan, SK
Soraghan, JJ
Littlejohn, D
Sadler, DA
机构
[1] Univ Strathclyde, Dept EEE, Signal Proc Div, Glasgow G1 1XW, Lanark, Scotland
[2] Univ Strathclyde, Dept Pure & Appl Chem, Glasgow G1 1XL, Lanark, Scotland
关键词
principal component analysis; partial least squares calibration; near infrared spectrometry;
D O I
10.1016/S0003-2670(01)01446-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel strategy for building and maintaining calibration models has been developed for use when the future boundaries of the sample set are unknown or likely to change. Such a strategy could have an impact on the economics and time required to obtain and maintain a calibration model for routine analysis. The strategy is based on both principal component analysis (PCA) and partial least squares (PLS) multivariate techniques. The principal action of the strategy is to define how "similar" a new sample is to the samples currently defining the calibration dataset. This step is performed by residuals analysis, following PCA. If the new sample is considered to have a spectrum "similar" to previously available spectra, then the model is assumed able to predict the analyte concentration. Conversely, if the new sample is considered "dissimilar", then there is new information in this sample, which is unknown to the calibration model and the new sample is added automatically to the calibration set in order to improve the model. The strategy has been applied to a real industrial dataset provided by BP Amoco Chemicals. The data consists of spectra of 102 sequential samples of a raw material. The strategy produced an accurate calibration model for both target components starting with only the first four samples, and required a further 17 reference measurements to maintain the model for the whole sampling sequence, which was over a 1-year period. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 50 条
  • [31] Near-infrared imaging for quantitative analysis of active component in counterfeit dimethomorph using partial least squares regression
    Yue Huang
    Shun-Geng Min
    Jin-Li Cao
    Sheng-Feng Ye
    Jia Duan
    Chemical Papers, 2012, 66 : 1065 - 1072
  • [32] Metabolic profiling using principal component analysis, discriminant partial least squares, and genetic algorithms
    Ramadan, Z
    Jacobs, D
    Grigorov, M
    Kochhar, S
    TALANTA, 2006, 68 (05) : 1683 - 1691
  • [33] Weighted partial least squares regression by variable grouping strategy for multivariate calibration of near infrared spectra
    Xu, Heng
    Cai, Wensheng
    Shao, Xueguang
    ANALYTICAL METHODS, 2010, 2 (03) : 289 - 294
  • [34] Study of the Fouling Characteristics of Arc Pipe Based on Principal Component Analysis and Partial Least Squares
    Song Jingdong
    Wen Xiaoqiang
    MANUFACTURING SCIENCE AND MATERIALS ENGINEERING, PTS 1 AND 2, 2012, 443-444 : 731 - 737
  • [35] Investigation of partial least squares (PLS) calibration performance based on different resolutions of near infrared spectra
    Chung, H
    Choi, SY
    Choo, J
    Lee, Y
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (05): : 647 - 651
  • [36] A novel face recognition method based on Principal Component Analysis and Kernel Partial Least Squares
    Li, Xiujuan
    Ma, Jie
    Li, Shutao
    2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-5, 2007, : 1773 - +
  • [37] Assessment of partial least-squares calibration and wavelength selection for complex near-infrared spectra
    McShane, MJ
    Cote, GL
    Spiegelman, CH
    APPLIED SPECTROSCOPY, 1998, 52 (06) : 878 - 884
  • [38] Partial Least Squares Model based Process Monitoring using Near Infrared Spectroscopy
    Tibor Kulcsar
    Gabor Sarossy
    Gabor Bereznai
    Robert Auer
    Janos Abonyi
    PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING, 2013, 57 (1-2) : 15 - 20
  • [39] Using partial least squares and principal component regression in simultaneous spectrophotometric analysis of pyrimidine bases
    Khajehsharifi, Habibollah
    Eskandari, Zahra
    Sareban, Neda
    ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 : S141 - S147
  • [40] Partial least squares model based process monitoring using near infrared spectroscopy
    1600, Budapest University of Technology and Economics (57): : 1 - 2