FLUID MECHANICS OF ARTIFICIAL HEART VALVES

被引:197
|
作者
Dasi, Lakshmi P. [1 ]
Simon, Helene A. [2 ]
Sucosky, Philippe [1 ]
Yoganathan, Ajit P. [1 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Sch Biomed Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Chem & Mol Biol, Atlanta, GA 30332 USA
关键词
aortic; bileaflet; circulation; haemodynamics; heart valve; mechanical; mitral; prosthesis; trileaflet; SHEAR-INDUCED ACTIVATION; HINGE FLOW-FIELDS; GROWN IN-VITRO; AORTIC-VALVE; MODEL; PROSTHESES; BLOOD; IMPLANTATION; HETEROGRAFTS; REPLACEMENT;
D O I
10.1111/j.1440-1681.2008.05099.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.
引用
收藏
页码:225 / 237
页数:13
相关论文
共 50 条
  • [21] DESIGN CRITERIA FOR ARTIFICIAL HEART VALVES
    AKUTSU, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1970, 60 (01): : 34 - &
  • [22] PHYSIOLOGICAL EFFECTS OF ARTIFICIAL HEART VALVES
    GOLLAN, F
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1956, 2 : 71 - &
  • [23] Hydrodynamics of Modern Artificial Heart Valves
    S. I. Korchagin
    E. I. Kuznetsova
    A. M. Omelyanchuk
    V. N. Yurechko
    Fluid Dynamics, 2002, 37 : 101 - 108
  • [24] Detecting fractures in artificial heart valves
    Lepelaars, ESAM
    vanOoijen, WDR
    Tijhuis, AG
    deMol, BAJM
    IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM 1997, VOLS 1-4, 1997, : 1198 - 1201
  • [25] POLYURETHANE ARTIFICIAL HEART VALVES IN ANIMALS
    AKUTSU, T
    DREYER, B
    KOLFF, WJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (06) : 1045 - 1048
  • [26] ANEMIA WITH ARTIFICIAL HEART-VALVES
    不详
    LANCET, 1972, 1 (7764): : 1321 - +
  • [27] PRESENT STATUS WITH ARTIFICIAL HEART VALVES
    DALICHAU, H
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1973, 334 : 875 - 885
  • [28] HYDRODYNAMICS OF ARTIFICIAL-HEART VALVES
    POHL, M
    WENDT, MO
    LERCHE, D
    RHEOLOGICA ACTA, 1988, 27 (04) : 446 - 446
  • [29] Surface engineering in artificial heart valves
    Gopal, Lakshmi
    Sudarshan, Tirumalai
    SURFACE ENGINEERING, 2023, 39 (04) : 387 - 391
  • [30] COMPLICATIONS OF ARTIFICIAL HEART-VALVES
    KLOSTER, FE
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1979, 241 (20): : 2201 - 2203