Development and validation of a UPLC-MS/MS assay for the quantification of simotinib in human plasma

被引:6
|
作者
Li, Ning [1 ,2 ]
Han, Xiaohong [1 ,2 ]
Du, Ping [1 ,2 ]
Song, Yuanyuan [1 ,2 ]
Hu, Xingsheng [1 ,2 ]
Yang, Sheng [1 ,2 ]
Shi, Yuankai [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Canc Inst Hosp, Dept Med Oncol, Beijing 100021, Peoples R China
[2] Peking Union Med Coll, Beijing Key Lab Clin Study Anticanc Mol Targeted, Beijing 100021, Peoples R China
关键词
Simotinib; UPLC-MS/MS; Human plasma; Validation; CELL LUNG-CANCER; TYROSINE KINASE INHIBITOR; HPLC-UV METHOD; ERLOTINIB; GEFITINIB; ICOTINIB; THERAPY; TRIAL;
D O I
10.1007/s00216-013-7570-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simotinib is a novel oral small-molecule tyrosine kinase inhibitor that has demonstrated equal or superior antineoplastic activities to erlotinib in preclinical studies. In support of a clinical pharmacokinetic study, a sensitive and accurate liquid chromatography (LC) method with mass spectrometry detection using multiple reaction monitoring (MRM) in positive ion mode was developed and validated for the quantification of simotinib in human plasma. The sample preparation procedure involved a simple protein precipitation with methanol. Erlotinib was used as the internal standard. The optimal chromatographic behavior was achieved on a Zorbax SB-C8 column (2.1 mm x 100 mm, 3.5 mu m) using a mixture of 0.1 % formic acid with 10 mM ammonium formate/methanol (20:80, v/v) as the mobile phase. The total LC analysis time per injection was 4 min with a flow rate of 0.2 mL/min. The recovery was greater than 90 % and no significant matrix effect was observed. The assay was validated over the concentration range of 1-1,000 ng/mL. The intra- and interday precision and accuracy of the quality control samples at low, medium, and high concentration levels showed at most 9.4 % relative standard deviation (RSD) and -7.4 to 7.4 % relative errors (RE). Assay selectivity, freeze/thaw stability, storage stability, and dilution effects were also assessed. The method is now used to support clinical pharmacokinetic studies in patients with non-small cell lung cancer (NSCLC) after oral administration of simotinib.
引用
收藏
页码:1799 / 1805
页数:7
相关论文
共 50 条
  • [31] Development and validation of a UPLC-MS/MS method for the quantification of sugars and non-nutritive sweeteners in human urine
    Diepeveen-de Bruin, Marlies
    Maho, Walid
    Buso, Marion E. C.
    Naomi, Novita D.
    Brouwer-Brolsma, Elske M.
    Feskens, Edith J. M.
    Balvers, Michiel G. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1225
  • [32] Development and validation of a rapid and sensitive UPLC-MS/MS method for determination of uracil and dihydrouracil in human plasma
    Jacobs, Bart A. W.
    Rosing, Hilde
    de Vries, Niels
    Meulendijks, Didier
    Henricks, Linda M.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 126 : 75 - 82
  • [33] Development and validation of a UPLC-MS/MS method for simultaneous determination of LBPT and its metabolites in human plasma
    Wu, Mengyi
    Liu, Aijing
    Zhuang, Quankun
    Jia, Ranran
    Zhou, Yinping
    Liu, Yali
    Wang, Hongyun
    BIOANALYSIS, 2020, 12 (04) : 211 - 220
  • [34] Development and validation of an UPLC-MS/MS method for the quantification of tamoxifen and its main metabolites in human scalp hair
    Drooger, Jan C.
    Jager, Agnes
    Lam, Mei-Ho
    den Boer, Mathilda D.
    Sleijfer, Stefan
    Mathijssen, Ron H. J.
    de Bruijn, Peter
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 114 : 416 - 425
  • [35] Development and validation of a rapid and sensitive UPLC-MS/MS method for quantification of kukoamine B in human plasma: Application to a clinical pharmacokinetic study
    Wang, Zhenlei
    Zhao, Qian
    Li, Lili
    Hu, Pei
    Dong, Kai
    Chen, Shuai
    Jiang, Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 132 : 1 - 6
  • [36] Simultaneous quantification of ambrisentan, macitentan and sitaxentan in human plasma using UPLC-MS/MS
    van de Velde, Daan
    Bahmany, Soma
    Hitzerd, Emilie
    van Domburg, Bart
    Versmissen, Jorie
    Danser, A. H. Jan
    Koch, Birgit C. P.
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (03)
  • [37] UPLC-MS/MS determination of doxazosine in human plasma
    Osama Y. Al-Dirbashi
    Hassan Y. Aboul-Enein
    Minnie Jacob
    Khalid Al-Qahtani
    Mohamed S. Rashed
    Analytical and Bioanalytical Chemistry, 2006, 385 : 1439 - 1443
  • [38] UPLC-MS/MS determination of doxazosine in human plasma
    Al-Dirbashi, Osama Y.
    Aboul-Enein, Hassan Y.
    Jacob, Minnie
    Al-Qahtani, Khalid
    Rashed, Mohamed S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1439 - 1443
  • [39] Development and Validation a UPLC-MS/MS Method for Quantification of Pentoxifylline in Beagle Plasma: Application for Pharmacokinetic Study of Food Effect
    Xu, Yuxiang
    Gao, Xiaonan
    Zhu, Yunfang
    Zhang, Qi
    Qie, Hongxin
    Zhao, Haopeng
    Gao, Jinglin
    Wang, Mingxia
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2023, 17 : 3551 - 3561
  • [40] Development and full validation of an UPLC-MS/MS method for the quantification of the plant-derived alkaloid indirubin in rat plasma
    Jahne, Evelyn A.
    Sampath, Chethan
    Butterweck, Veronika
    Hamburger, Matthias
    Oufir, Mouhssin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 128 : 247 - 252