20 Years of Ultrasound Contrast Agent Modeling

被引:124
|
作者
Faez, Telli [1 ]
Emmer, Marcia [1 ,2 ]
Kooiman, Klazina [1 ]
Versluis, Michel [3 ,4 ]
van der Steen, Antonius F. W. [1 ,2 ]
de Jong, Nico [1 ,2 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Biomed Engn, Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Univ Twente, Phys Fluids Grp, NL-7500 AE Enschede, Netherlands
[4] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
POLYMER-COATED MICROBUBBLES; COMPRESSION-ONLY BEHAVIOR; WFUMB SAFETY SYMPOSIUM; GAS-BUBBLES; RADIAL OSCILLATIONS; DRUG-DELIVERY; ENCAPSULATED MICROBUBBLES; DIAGNOSTIC ULTRASOUND; SUBHARMONIC RESPONSE; RHEOLOGICAL MODEL;
D O I
10.1109/TUFFC.2013.2533
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The merits of ultrasound contrast agents (UCAs) were already known in the 1960s. It was, however, not until the 1990s that UCAs were clinically approved and marketed. In these years, it was realized that the UCAs are not just efficient ultrasound scatterers, but that their main constituent, the coated gas microbubble, acts as a nonlinear resonator and, as such, is capable of generating harmonic energy. Subharmonic, ultraharmonic, and higher harmonic frequencies of the transmitted ultrasound frequency have been reported. This opened up new prospects for their use and several detection strategies have been developed to exploit this harmonic energy to discriminate the contrast bubbles from surrounding tissue. This insight created a need for tools to study coated bubble behavior in an ultrasound field and the first models were developed. Since then, 20 years have elapsed, in which a broad range of UCAs and UCA models have been developed. Although the models have helped in understanding the responses of coated bubbles, the influence of the coating has not been fully elucidated to date and UCA models are still being improved. The aim of this review paper is to offer an overview in these developments and indicate future directions for research.
引用
收藏
页码:7 / 20
页数:14
相关论文
共 50 条
  • [21] Conventional and hypobaric activation of an ultrasound contrast agent
    Forsberg, F
    Roy, R
    Merton, DA
    Rawool, NM
    Liu, JB
    Huang, M
    Kessler, D
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (08): : 1143 - 1150
  • [22] Hepatocellular carcinoma: harmonic ultrasound and contrast agent
    Kim, TK
    Kim, AY
    Choi, BI
    ABDOMINAL IMAGING, 2002, 27 (02): : 129 - 138
  • [23] ULTRASOUND WITH MICROBUBBLE CONTRAST AGENT AND UROKINASE FOR THROMBOSIS
    Wang, Fangfang
    Shi, Tiemei
    Su, Chang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (03): : 859 - 866
  • [24] Perflenapent emulsion -: EchoGen® -: Ultrasound contrast agent
    不详
    DRUGS OF THE FUTURE, 2001, 26 (04) : 418 - 418
  • [25] PRELIMINARY-RESULTS WITH AN ULTRASOUND CONTRAST AGENT
    FRITZSCH, T
    SCHARTL, M
    SIEGERT, J
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 816 - 816
  • [26] Surface modes of ultrasound contrast agent microbubbles
    van der Meer, Sander M.
    Dollet, Benjamin
    Goertz, David E.
    de Jong, Nico
    Versluis, Michel
    Lohse, Detlef
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 112 - +
  • [27] A Model for Ultrasound Contrast Agent in a Phantom Vessel
    Qamar, Adnan
    Samtaney, Ravi
    2014 MIDDLE EAST CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2014, : 192 - 195
  • [28] Photoacoustic cell for ultrasound contrast agent characterization
    Alippi, A.
    Bettucci, A.
    Biagioni, A.
    D'Orazio, A.
    Germano, M.
    Passeri, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [29] Design of an ultrasound contrast agent for myocardial perfusion
    Schneider, M
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (06): : S11 - S16
  • [30] A fluorocarbon ultrasound contrast agent PBPK model
    Hutter, JC
    Luu, MYD
    Mehlhaff, PM
    Killam, AL
    Dittrich, HC
    PROCEEDINGS OF THE 1998 MEDICAL SCIENCES SIMULATION CONFERENCE, 1998, : 104 - 109