20 Years of Ultrasound Contrast Agent Modeling

被引:124
|
作者
Faez, Telli [1 ]
Emmer, Marcia [1 ,2 ]
Kooiman, Klazina [1 ]
Versluis, Michel [3 ,4 ]
van der Steen, Antonius F. W. [1 ,2 ]
de Jong, Nico [1 ,2 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Biomed Engn, Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Univ Twente, Phys Fluids Grp, NL-7500 AE Enschede, Netherlands
[4] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
POLYMER-COATED MICROBUBBLES; COMPRESSION-ONLY BEHAVIOR; WFUMB SAFETY SYMPOSIUM; GAS-BUBBLES; RADIAL OSCILLATIONS; DRUG-DELIVERY; ENCAPSULATED MICROBUBBLES; DIAGNOSTIC ULTRASOUND; SUBHARMONIC RESPONSE; RHEOLOGICAL MODEL;
D O I
10.1109/TUFFC.2013.2533
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The merits of ultrasound contrast agents (UCAs) were already known in the 1960s. It was, however, not until the 1990s that UCAs were clinically approved and marketed. In these years, it was realized that the UCAs are not just efficient ultrasound scatterers, but that their main constituent, the coated gas microbubble, acts as a nonlinear resonator and, as such, is capable of generating harmonic energy. Subharmonic, ultraharmonic, and higher harmonic frequencies of the transmitted ultrasound frequency have been reported. This opened up new prospects for their use and several detection strategies have been developed to exploit this harmonic energy to discriminate the contrast bubbles from surrounding tissue. This insight created a need for tools to study coated bubble behavior in an ultrasound field and the first models were developed. Since then, 20 years have elapsed, in which a broad range of UCAs and UCA models have been developed. Although the models have helped in understanding the responses of coated bubbles, the influence of the coating has not been fully elucidated to date and UCA models are still being improved. The aim of this review paper is to offer an overview in these developments and indicate future directions for research.
引用
收藏
页码:7 / 20
页数:14
相关论文
共 50 条
  • [1] ULTRASOUND CONTRAST AGENT MODELING: A REVIEW
    Versluis, Michel
    Stride, Eleanor
    Lajoinie, Guillaume
    Dollet, Benjamin
    Segers, Tim
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (09): : 2117 - 2144
  • [2] Ultrasound Contrast Agent Microbubble Modeling with Bubbles Interaction
    Li, Shuying
    Huang, Yurong
    Yu, Jinhua
    Wang, Yuanyuan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (07) : 1548 - 1554
  • [3] Simplified Ultrasound Contrast Agent Microbubble Modeling with Bubbles Interaction
    Huang, Yurong
    Li, Shuying
    Yu, Jinhua
    Wang, Yuanyuan
    Zhang, Qi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (07) : 1428 - 1435
  • [4] Multifunctional Ultrasound Contrast Agent
    Jin Yushen
    Ke Hengte
    Dai Zhifei
    PROGRESS IN CHEMISTRY, 2012, 24 (12) : 2424 - 2430
  • [5] Microbubble contrast agent destruction using 20-25 MHz ultrasound
    Chérin, E
    Needles, A
    Stapleton, S
    Williams, R
    Foster, FS
    Tavakkoli, J
    Mehi, J
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 751 - 754
  • [6] Enhanced heat deposition using ultrasound contrast agent - Modeling and experimental observations
    Razansky, D
    Einziger, PD
    Adam, DR
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 137 - 147
  • [7] Quantitative ultrasound molecular imaging by modeling the binding kinetics of targeted contrast agent
    Turco, Simona
    Tardy, Isabelle
    Frinking, Peter
    Wijkstra, Hessel
    Mischi, Massimo
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2449 - 2464
  • [8] Effects of ultrasound and ultrasound contrast agent on vascular tissue
    Wood, Steven C.
    Antony, Sible
    Brown, Ronald P.
    Chen, Jin
    Gordon, Edward A.
    Hitchins, Victoria M.
    Zhang, Qin
    Liu, Yunbo
    Maruvada, Subha
    Harris, Gerald R.
    CARDIOVASCULAR ULTRASOUND, 2012, 10
  • [9] Effects of ultrasound and ultrasound contrast agent on vascular tissue
    Steven C Wood
    Sible Antony
    Ronald P Brown
    Jin Chen
    Edward A Gordon
    Victoria M Hitchins
    Qin Zhang
    Yunbo Liu
    Subha Maruvada
    Gerald R Harris
    Cardiovascular Ultrasound, 10
  • [10] Kidney Transplant - Contrast Agent - Ultrasound
    不详