X-ray calibration and characterization at National Security Technologies, LLC Livermore Operations

被引:1
|
作者
King, James A. [1 ]
Haugh, Michael J. [1 ]
Freeman, Richard R. [1 ]
Jacoby, Kenneth D. [1 ]
Torres, Gabe [1 ]
Torres, Peter [1 ]
Hillyard, Patrick [1 ]
Koch, Jeffrey A. [1 ]
机构
[1] Natl Secur Technol LLC, Livermore, CA 94550 USA
关键词
NNSS; calibration; characterization; X-rays; diagnostics; NVLAP; NIST-traceable;
D O I
10.1117/12.2276806
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray calibration is a primary component of the calibration services provided by National Security Technologies, LLC (NSTec) Livermore Operations (LO). The X-ray calibration labs at NSTec LO consist of four labs which provide characteristic and bremsstrahlung X-ray output beams ranging in energy from 300 eV to 110 keV. These labs can calibrate a variety of X-ray detectors and components including CCD's, streak cameras, spectrometers, and filters. Many of the calibration measurements are NIST-traceable. Calibrations and characterizations provided include quantum efficiency, sensitivity, dynamic range, resolution, flat-field test, and transmission measurements. Historically, these labs have performed calibrations for various institutions and national laboratories such as LLNL, LANL, and Sandia. In addition, NSTec (LO) has diagnostic R&D capabilities such as extending curved crystal X-ray imaging to higher energies. This presentation will describe the services provided by these labs, the operation and in-house, NVLAP certified calibration of the various X-ray sources and diagnostics used, and the general layout of the NSTec (LO) X-ray labs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Parametric X-ray radiation for calibration of X-ray space telescopes and generation of several X-ray beams
    Shchagin, AV
    Khizhnyak, NA
    Fiorito, RB
    Rule, DW
    Artru, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 173 (1-2): : 154 - 159
  • [32] MINIATURE X-RAY POINT SOURCE FOR ALIGNMENT AND CALIBRATION OF X-RAY OPTICS
    PRICE, RH
    BOYLE, MJ
    GLAROS, SS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1196 - 1196
  • [33] Calibration of X-ray diode photocathodes
    Huang, Tianxuan
    Zheng, Zhijian
    Ding, Yongkun
    Sun, Kexu
    Yi, Rongqing
    Cui, Yanli
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2000, 12 (04): : 455 - 458
  • [34] A NOTE ON THE CALIBRATION OF X-RAY DOSEMETERS
    TOOZE, J
    WORTHLEY, B
    PHYSICS IN MEDICINE AND BIOLOGY, 1959, 4 (01): : 30 - 32
  • [35] Calibration of the Stellar X-Ray Polarimeter
    Tomsick, J
    Costa, E
    Dwyer, J
    Elsner, R
    Ford, E
    Kaaret, P
    Novick, R
    Santangelo, A
    Silver, E
    Soffitta, P
    Weisskopf, M
    Ziock, K
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 373 - 383
  • [36] CALIBRATION OF THERAPEUTIC X-RAY GENERATORS
    WANG, TJ
    RADIOLOGY, 1953, 60 (06) : 885 - 894
  • [37] CALIBRATION OF X-RAY MEASUREMENT OF STRAIN
    BENNETT, JA
    VACHER, HC
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1948, 40 (04): : 285 - 293
  • [38] Calibration of the MESSENGER X-Ray Spectrometer
    Starr, Richard D.
    Schlemm, Charles E., II
    Ho, George C.
    Nittler, Larry R.
    Gold, Robert E.
    Solomon, Sean C.
    PLANETARY AND SPACE SCIENCE, 2016, 122 : 13 - 25
  • [39] AN X-RAY INSTRUMENT CALIBRATION FACILITY
    TROUT, ED
    KELLEY, JP
    WEAVER, KE
    HEALTH PHYSICS, 1969, 17 (02): : 365 - +
  • [40] Calibration of the MaGIXS Experiment. I. Calibration of the X-Ray Source at the X-Ray and Cryogenic Facility
    Athiray, P. S.
    Winebarger, Amy R.
    Champey, Patrick
    Kobayashi, Ken
    Vigil, Genevieve D.
    Haight, Harlan
    Johnson, Steven
    Bethge, Christian
    Rachmeler, Laurel A.
    Savage, Sabrina
    Beabout, Brent
    Beabout, Dyana
    Hogue, William
    Guillory, Anthony
    Siler, Richard
    Wright, Ernest
    Kegley, Jeffrey
    ASTROPHYSICAL JOURNAL, 2020, 905 (01):