摘要
Introduction: As accurate fetal evaluation during labor is essential, there is a continuous need for better noninvasive ways of monitoring. Electronic fetal monitoring (EFM) is an essential tool towards effective fetal assessment during labor, with the invasive Intrapartum ST Segment Analyses (STAN) system an early favorite. There are very few non-invasive EFM devices worldwide, with only two having Food and Drug Administration (FDA) approval. Methodology: This state of the science review focuses on the most recent available scientific data regarding the role of non-invasive EFM and its effect on perinatal outcomes. Results: The Monica AN24 system, FDA approved and comparable to an external Doppler CTG, is independent of maternal BMI. The Mind child Meridian monitor, the second EFM device with FDA approval, is comparable to STAN, but with up to 32 electrodes for improved accuracy it can be difficult for medical professionals to master. The Nemo System, new to the market, was found to be highly acceptable as a 24-hour monitoring device by pregnant women in a single inaugural pilot study. Discussion: Non-invasive monitoring technology is making progress but there are still issues with signal acquisition and quality that stem from the newfound mobility of the monitored pregnant women. The two FDA approved devices are promising with a few caveats and there are also new devices that aim to improve on the shortcomings of the leaders with promising advances in signal acquisition and processing via additional electrodes and setups.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [31] A novel hybrid method for calculating the fetal heart rate from the non-invasive abdominal Electrocardiogram signal
    Samuel, Bipin
    Hota, Malaya Kumar
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 94
  • [32] User Evaluation of Low-Cost, Non-Invasive Methods for Heart-Rate Measurement
    Mathe, Eirini
    Spyrou, Evaggelos
    JOURNAL OF USABILITY STUDIES, 2020, 15 (03) : 145 - 165
  • [33] Infrared Video based Non-invasive Heart Rate Measurement
    Zeng, Wei
    Zhang, Qi
    Zhou, Yimin
    Xu, Guoqing
    Liang, Guoyuan
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2015, : 1041 - 1046
  • [34] A Novel Heart Rate and Non-Invasive Glucose Measuring Device
    Venkataramanan, Shashanka
    Kamble, Divyata
    Bairolu, Aditi
    Singh, Akash
    Rao, Rama
    2017 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), 2017, : 1796 - 1800
  • [35] Heart Rate Monitoring by using Non-invasive Wearable Sensor
    Maria, Aileni Raluca
    Pasca, Sever
    Strungaru, Rodica
    2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 587 - 590
  • [36] Current modalities for invasive and non-invasive monitoring of volume status in heart failure
    von Lueder, Thomas G.
    Krum, Henry
    HEART, 2012, 98 (13) : 967 - 973
  • [37] Template subtraction based methods for non-invasive fetal electrocardiography extraction
    Rene Jaros
    Eva Tomicova
    Radek Martinek
    Scientific Reports, 14
  • [38] Template subtraction based methods for non-invasive fetal electrocardiography extraction
    Jaros, Rene
    Tomicova, Eva
    Martinek, Radek
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [39] COMPARATIVE FLOW ANALYSES OF HEART USING INVASIVE AND NON-INVASIVE ULTRASONIC METHODS
    REDEL, D
    FRICKE, G
    MATTERN, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1980, 69 (03): : 222 - 222
  • [40] Processing of Fetal Heart Rate through Non-invasive Adaptive System Based on Recursive Least Squares Algorithm
    Fajkus, Marcel
    Nedoma, Jan
    Martinek, Radek
    Vasinek, Vladimir
    OPTICAL MATERIALS AND BIOMATERIALS IN SECURITY AND DEFENCE SYSTEMS TECHNOLOGY XIV, 2017, 10440