Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing material

被引:65
|
作者
Zamani, Hassan Ali [1 ]
Mohammadhosseini, Majid [2 ]
Haji-Mohammadrezazadeh, Saeed [3 ]
Faridbod, Farnoush [4 ]
Ganjali, Mohammad Reza [4 ,5 ]
Meghdadi, Soraia [6 ]
Davoodnia, Abolghasem [7 ]
机构
[1] Islamic Azad Univ, Dept Appl Chem, Mashhad Branch, Mashhad, Iran
[2] Islamic Azad Univ, Dept Chem, Fac Basic Sci, Shahrood Branch, Shahrood, Iran
[3] Payame Noor Univ, Dept Chem, Ardakan, Iran
[4] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[5] Univ Tehran, Ctr Excellence Electrochem, Fac Chem, Tehran, Iran
[6] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[7] Islamic Azad Univ, Dept Chem, Fac Sci, Mashhad Branch, Mashhad, Iran
关键词
Gadolinium; PVC membrane; Sensor; Potentiometry; Ion selective electrode; PVC-MEMBRANE-ELECTRODE; HEAVY-METAL IONS; SEDIMENT SAMPLES; POTENTIOMETRIC SENSOR; FABRICATION; CONSTRUCTION; SOIL; TRANSITION; COMPLEXES;
D O I
10.1016/j.msec.2012.01.013
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
According to a solution study which showed a selective complexation between N,N'-bis(methylsalicylidene)-2-aminobenzylamine (MSAB) and gadolinium ions, MSAB was used as a sensing element in construction of a gadolinium(III) ion selective electrode. Acetophenon (AP) was used as solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode showed a good selectivity towards Gd(III) ions over a wide variety of cations tested. The constructed sensor displayed a Nernstian behavior (19.7 +/- 0.3 mV/decade) in the concentration range of 1.0 x 10(-6) to 1.0 x 10(-2) mol L-1 with detection limit of 5.0 x 10(-7) mol L-1 and a short response time (<10 s). The working pH range of the electrode was 3.5-10.1 and lifetime of the sensor was at least 10 weeks. Analysis of certified reference materials confirmed the accuracy of the proposed sensor. The electrode was successfully applied as an indicator electrode in gadolinium titration with EDTA. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:712 / 717
页数:6
相关论文
共 50 条
  • [41] PVC-MEMBRANE POTENTIOMETRIC SENSORS BASED ON A RECENTLY SYNTHESIZED SCHIFF BASE FOR Fe(III) ION
    Sheikhshoaie, Iran
    Shamspur, Tayebeh
    Mostafavi, Ali
    Ebrahimipur, S. Yousef
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2012, 26 (01) : 65 - 72
  • [42] New Schiff base-carbon nanotube-nanosilica-ionic liquid as a high performance sensing material of a potentiometric sensor for nanomolar determination of cerium(III) ions
    Afkhami, Abbas
    Madrakian, Tayyebeh
    Shirzadmehr, Ali
    Tabatabaee, Masoumeh
    Bagheri, Hasan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 174 : 237 - 244
  • [43] Synthesis of a new hexadendates Schiff's base and its application in the fabrication of a highly selective mercury(II) sensor
    Ganjali, M. R.
    Norouzi, P.
    Alizadeh, T.
    Salavati-Niasari, M.
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2007, 28 (01) : 68 - 72
  • [44] Synthesis of a new hexadendates Schiff's base and its application in the fabrication of a highly selective mercury(II) sensor
    Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
    不详
    Bull. Korean Chem. Soc., 2007, 1 (68-72):
  • [45] Design and fabrication of carbon paste electrode for determination of Cr(III) ion in real water samples using a new synthesis Schiff base as selective ionophore
    Shojaei, Esmat
    Masrournia, Mahboubeh
    Beyramabadi, Ali
    Behmadi, Hossein
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (07): : 750 - 759
  • [46] Quantitative monitoring of terbium ion by a Tb3+ selective electrode based on a new Schiff's base
    Zamani, Hassan Ali
    Zabihi, Mohammad Saleh
    Rohani, Mitra
    Zangeneh-Asadabadi, Abbas
    Ganjali, Mohammad Reza
    Faridbod, Farnoush
    Meghdadi, Soraia
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (02): : 409 - 413
  • [47] Sodium dodecyl sulfate coated alumina modified with a new Schiff's base as a uranyl ion selective adsorbent
    Tashkhourian, J.
    Abdoluosofi, L. Moradi
    Pakniat, M.
    Montazerozohoric, M.
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 187 (1-3) : 75 - 81
  • [48] Iodide-selective carbon paste electrodes based on recently synthesized Schiff base complexes of Fe(III)
    Shamsipur, M
    Soleymanpour, A
    Akhond, M
    Sharghi, H
    Naseri, MA
    ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) : 37 - 44
  • [49] Quantitative Analysis of Holmium Ion by a Ho3+ Ion-Selective Sensor Based on a Symmetric Thio-Schiff's Base
    Hassan, Ali Zamani
    Fatemeh, Rahimi
    Fatemeh, Naghavi-Reyabbi
    Ali, Arvinfar
    Alihossien, Imani
    Mohammad, Reza Ganjali
    Farnoush, Faridbod
    Masoud, Salavati-Niasari
    CHINESE JOURNAL OF CHEMISTRY, 2011, 29 (07) : 1523 - 1528
  • [50] Two Schiff-base fluorescent sensors for selective sensing of aluminum (III): Experimental and computational studies
    Qin, Jing-Can
    Cheng, Xiao-ying
    Fang, Ran
    Wang, Ming-fang
    Yang, Zheng-yin
    Li, Tian-rong
    Li, Yong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 152 : 352 - 357