Effect of Heat Exchanger influencing Coefficient of Performance of a Hermetic compressor

被引:0
|
作者
Edison, G. [1 ]
Suresh, A. [1 ]
Rao, K. Narayana [1 ]
机构
[1] VIT Univ, Sch Mech & Bldg Sci, Vellore 632014, Tamil Nadu, India
关键词
Suction line cooling; Heat exchanger; COP; Refrigeration; T-S plot; Density; Refrigerant;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Compressor is one of the main parts and it is thus the first component of the refrigerator to be modeled. Compressor would consume less work when its inlet temperature is low which is understood from the T-S diagram as the constant pressure lines diverge towards right. The density decrease due to suction gas heating and mixing is a very important factor affecting mass flow rate, and can be characterized by a single parameter, the effectiveness of heat transfer driven by the difference between the temperature at the suction line and the discharge port. The present paper is to compare theoretical and experimental values and to develop an effective suction gas heat exchanger for hermetically sealed compressor. An attempt to achieve the required temperature with in less time when compared to the refrigeration unit working without heat exchanger had been done using laboratory set up with a single tube counter flow heat exchanger. The required temperature had been achieved with in 30 minutes when compared to the refrigeration unit working without heat exchanger. Though the actual COP values are much smaller compared to than Carnot COP values, it had been proved that the values obtained with heat exchanger is 10% more than the values with out Heat exchanger.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Effect of fouling on heat transfer performance of heat exchanger
    Wu, Shuangying
    Shiyou Huagong Shebei/ Petro-Chemical Equipment, 2000, 29 (01): : 10 - 12
  • [12] Effects of compressor frequency and heat exchanger geometry on dynamic performance characteristics of heat pump dryers
    Choi, JunYoung
    Lee, DongChan
    Park, Myeong Hyeon
    Lee, Yongju
    Kim, Yongchan
    Energy, 2021, 235
  • [13] Effects of compressor frequency and heat exchanger geometry on dynamic performance characteristics of heat pump dryers
    Choi, JunYoung
    Lee, DongChan
    Park, Myeong Hyeon
    Lee, Yongju
    Kim, Yongchan
    ENERGY, 2021, 235
  • [14] The effect of minichannels on the overall heat transfer coefficient and pressure drop of a shell and tube heat exchanger: Experimental performance comparison
    Kücük, Hasan
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 188
  • [15] Effect of surface roughness on the performance of heat exchanger
    Geete, Ankur
    Pathak, Rajendra
    SN APPLIED SCIENCES, 2019, 1 (08):
  • [16] HEAT-EXCHANGER PERFORMANCE - EFFECT OF ORIENTATION
    LEUNG, CW
    PROBERT, SD
    APPLIED ENERGY, 1989, 33 (04) : 235 - 252
  • [17] Effect of surface roughness on the performance of heat exchanger
    Ankur Geete
    Rajendra Pathak
    SN Applied Sciences, 2019, 1
  • [18] PERFORMANCE ENHANCEMENT OF HERMETIC COMPRESSOR USING PHASE CHANGE MATERIALS
    Mahmoud, I. M.
    Rady, M. A.
    Huzayyin, A. S.
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 2015, 90
  • [19] An investigation on simulation of performance of a hermetic compressor used for a refrigerating system
    Xie, GZ
    Wang, RX
    Yan, G
    Wu, YZ
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 678 - 681
  • [20] Experimental characterization of heat transfer in the components of a small hermetic reciprocating compressor
    Dutra, Thiago
    Deschamps, Cesar J.
    APPLIED THERMAL ENGINEERING, 2013, 58 (1-2) : 499 - 510