Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: Pitfalls in image interpretation

被引:83
|
作者
Krinsky, G
Rofsky, NM
Weinreb, JC
机构
[1] Department of Radiology, HW-207, New York University Medical Center, New York, NY 10016
关键词
D O I
10.2214/ajr.166.3.8623620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Short inversion time inversion recovery (STIR) and the rapid acquisition with relaxation enhancement (RARE) version of STIR are commonly used pulse sequences that are sensitive enough to detect a broad range of pathologic conditions. In addition to suppressing the signal from fat, the STIR sequence achieves additive T1-weighted, T2-weighted, and proton density-weighted contrast to facilitate lesion conspicuity [1, 2]. Fat suppression with STIR sequences is based on short T1 relaxation rates and therefore is not tissue specific. The signal from any tissue with a short T1, similar to that of fat, may be nulled as well. The signal from tissues that accumulate paramagnetic contrast agents also may be suppressed with STIR sequences when an appropriate degree of T1 shortening results.
引用
收藏
页码:523 / 526
页数:4
相关论文
共 50 条
  • [21] EFFECTIVENESS OF THE SHORT TI INVERSION RECOVERY (STIR) SEQUENCE IN MR IMAGING OF INTRAMEDULLARY SPINAL LESIONS
    MASCALCHI, M
    DALPOZZO, G
    BARTOLOZZI, C
    MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 17 - 25
  • [22] Insulinoma: Correlation of short-TI inversion-recovery (STIR) imaging and histopathologic findings
    Mori, M
    Fukuda, T
    Nagayoshi, K
    Kohzaki, S
    Matsunaga, N
    Hayashi, K
    Motojima, K
    Kanematsu, T
    ABDOMINAL IMAGING, 1996, 21 (04): : 337 - 341
  • [23] Magnetization transfer short inversion time inversion recovery enhanced1H MRI of the human lung
    Peter M. Jakob
    Tungte Wang
    Georg Schultz
    Helge Hebestreit
    Alexandra Hebestreit
    Marco Elfeber
    Dietbert Hahn
    Axel Haase
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2002, 15 : 10 - 17
  • [24] Magnetization transfer short inversion time inversion recovery enhanced 1H MRI of the human lung
    Jakob, PM
    Wang, TT
    Schultz, G
    Hebestreit, H
    Hebestreit, A
    Elfeber, M
    Hahn, D
    Haase, A
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 15 (1-3) : 10 - 17
  • [25] Determining depth of invasion of advanced colorectal cancer using MRI short inversion time inversion recovery sequences
    Masuko, E
    Homma, H
    Mezawa, S
    Matsuyama, T
    Watanabe, N
    Niitsu, Y
    JOURNAL OF GASTROENTEROLOGY, 1996, 31 (03) : 361 - 365
  • [26] Cartilaginous defects of the femorotibial joint: Accuracy of coronal short inversion time inversion-recovery MR sequence
    Jungius, Karl-Peter
    Schmid, Marius R.
    Zanetti, Marco
    Hodler, Juerg
    Koch, Peter
    Pfirrmann, Christian W. A.
    RADIOLOGY, 2006, 240 (02) : 482 - 488
  • [27] MRI of fat necrosis of the breast: The "black hole" sign at short tau inversion recovery
    Trimboli, Rubina M.
    Carbonaro, Luca A.
    Cartia, Francesco
    Di Leo, Giovanni
    Sardanelli, Francesco
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E573 - E579
  • [28] Effect of Inversion Recovery Fat Suppression on Hepatic R2*Quantitation in Transfusional Siderosis
    Meloni, Antonella
    Tyszka, J. Michael
    Pepe, Alessia
    Wood, John C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 625 - 629
  • [29] GD-DTPA ENHANCED SHORT REPETITION TIME AND SHORT INVERSION TIME INVERSION RECOVERY MAGNETIC-RESONANCE-IMAGING - EXPERIMENTAL AND CLINICAL-ASSESSMENT
    MIHARA, F
    GUPTA, KL
    INVESTIGATIVE RADIOLOGY, 1991, 26 (08) : 734 - 741
  • [30] Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression
    Ishimori Y.
    Monma M.
    Kawamura H.
    Miyata T.
    Radiological Physics and Technology, 2011, 4 (1) : 78 - 83