Impact of patient rotational errors on target and critical structure dose in IMRT: A 3D simulation study

被引:0
|
作者
Arumugam, S. [1 ]
Xing, A. [1 ]
Vial, P. [1 ]
Scotti, A. [1 ]
Stirton, R. [1 ]
Goozee, G. [1 ]
Holloway, Lois [1 ]
机构
[1] Liverpool Hosp, Liverpool Canc Therapy Ctr, Sydney, NSW, Australia
关键词
IMAGE-GUIDED RADIOTHERAPY; LIMITATIONS;
D O I
10.1088/1742-6596/444/1/012045
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The impact of 3D rotational errors in patient positioning on dose delivered target volumes and critical structures in IMRT was studied. Patient rotational errors ranging from -3 degrees to +3 degrees was introduced to IMRT treatment plans of pelvis, head and neck and brain treatment sites and the impact of rotational error on DVH metrics was assessed. The magnitude of impact of rotational error on the error in dose delivered to the target volume and critical structures depends on the location of the structures from plan isocentre. In studied plans, a maximum percentage difference of up to -9.8(1s=13.4) % in D95 to PTV was observed for head and neck treatments. Similarly, in Brain treatments a maximum difference of up to 24.0(1s=33.0) % in maximum dose of Optic chiasm was observed. The results suggest that failure to correct patient's rotational error results in under-dosage to target volumes and over-dosage to the critical structures in some specific treatment scenarios.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Patient dose from 3D rotational neurovascular studies
    Bridcut, R. R.
    Murphy, E.
    Workman, A.
    Flynn, P.
    Winder, R. J.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (953): : 362 - 366
  • [2] Experimental Measurements of 3D Dose Distribution for a Moving Target Treated with IMRT and VMAT
    Yan, H.
    Thomas, A.
    Oldham, M.
    Yin, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3792 - 3792
  • [3] 3D patient dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID
    van Zijtveld, M
    Dirkx, M
    de Boer, H
    Heijmen, B
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S42 - S42
  • [4] A Gated IMRT Study Based On Comparative 2D and 3D Dose Measurements
    Dvorak, P.
    Stevens, S.
    McQuaid, M.
    Dawes, S.
    Richmond, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3879 - 3879
  • [5] 3D Absorbed Dose Reconstructed in the Patient from EPID Images for IMRT and VMAT Treatments
    Younan, Fouad
    Mazurier, Jocelyne
    Chatrie, Frederic
    Barbeiro, Ana Rita
    Berry, Isabelle
    Franck, Denis
    Franceries, Xavier
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 605 - 609
  • [6] 3D dose reconstruction in the patient from VARIAN EPID images for IMRT and VMAT treatments
    Younan, F.
    Mazurier, J.
    Franceries, X.
    Franck, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S932 - S932
  • [7] Patient doses in paediatric interventional cardiology: impact of 3D rotational angiography
    Corredoira, E.
    Vano, E.
    Ubeda, C.
    Gutierrez-Larraya, F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (01) : 179 - 195
  • [8] Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment
    Schwarz, Marco
    Van Der Geer, Joris
    Van Herk, Marcel
    Lebesque, Joos V.
    Mijnheer, Ben J.
    Damen, Eugene M. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04): : 1260 - 1269
  • [9] Evaluation of IMRT QA Using 3DVH, a 3D Patient Dose and Verification Analysis Software
    Jarry, G.
    Martin, D.
    Lemire, M.
    Ayles, M.
    Pater, P.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Study on 3D simulation software for explosion and impact
    Ma, Tian-Bao
    Ning, Jian-Guo
    Jisuan Lixue Xuebao/Chinese Journal of Computational Mechanics, 2009, 26 (04): : 600 - 603