Comparison of Laboratory and Field Measurements of Backfill Hydraulic Conductivity for a Large-Scale Soil-Bentonite Cutoff Wall

被引:20
|
作者
Malusis, Michael A. [1 ]
Barlow, Landon C. [2 ]
机构
[1] Bucknell Univ, Dept Civil & Environm Engn, 1 Dent Dr, Lewisburg, PA 17837 USA
[2] Haley & Aldrich Inc, 100 Corp Pl, Rocky Hill, CT 06067 USA
基金
美国国家科学基金会;
关键词
Backfill; Bentonite; Cutoff wall; Hydraulic conductivity; Slug test; SLUG TEST;
D O I
10.1061/(ASCE)GT.1943-5606.0002311
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Soil-bentonite (SB) cutoff walls are commonly employed to control groundwater flow and contaminant migration, and the hydraulic conductivity (k) of the SB backfill is a critical parameter in these applications. In this study, an evaluation of backfillkwas conducted for a large-scale SB cutoff wall (approximately 200 m long and 7 m deep) constructed and instrumented for field research. Measurements of k(more than 150 in total) were obtained via (1) laboratory (flexible-wall and rigid-wall) tests on specimens molded from surface grab samples of the field-mixed backfill collected during construction, (2) laboratory (flexible-wall) tests on undisturbed backfill specimens prepared from Shelby tube samples taken from the wall, and (3) in situ (slug) tests conducted at 12 different locations within the wall. The laboratory tests were conducted in stages over a range of applied effective stresses (sigma '=6.9, 13.8, 20.7, and 34.5 kPa) that encompassed the range of mean in situ effective stresses measured in the backfill (6-12 kPa) via embedded earth pressure and pore pressure sensors. At a given sigma ', flexible-wallkvalues for the undisturbed specimens were similar to those for the laboratory molded specimens. However,k decreased with increasing sigma ' in all of the laboratory tests, as expected, and the differences betweenk values measured at the lower stresses (6.9-13.8 kPa) and those measured at the higher stresses (20.7-34.8 kPa) were statistically significant. The flexible-wall tests underestimated k relative to the slug tests, but the differences generally were small (on average, within a factor of 2) when considering only the flexible-wall specimens tested at the lower applied stresses (6.9-13.8 kPa) that more closely matched the in situ stresses. The results demonstrate the importance of conducting laboratory k tests on SB backfill at stresses representative of the in situ stresses, which are limited by frictional load transfer along the sidewalls and tend to be lower than expected based on an assumed geostatic stress distribution. (C) 2020 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 34 条
  • [31] Estimation of hydraulic conductivity and water table map in a large-scale laboratory model by means of the self-potential method
    Straface, Salvatore
    Rizzo, Enzo
    Chidichimo, Francesco
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2010, 115
  • [32] Surface mass balance on Fimbul ice shelf, East Antarctica: Comparison of field measurements and large-scale studies
    Sinisalo, Anna
    Anschutz, Helgard
    Aasen, Anne Tarand
    Langley, Kirsty
    von Deschwanden, Angela
    Kohler, Jack
    Matsuoka, Kenichi
    Hamran, Svein-Erik
    Oyan, Mats-Jorgen
    Schlosser, Elisabeth
    Hagen, Jon Ove
    Nost, Ole Anders
    Isaksson, Elisabeth
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2013, 118 (20) : 11625 - 11635
  • [33] In situ long-term improvement of large-scale lacustrine soft soil using laboratory and field data: a case study from a copper mine in China
    Wenchen Fan
    Xueliang Jiang
    Xingxing Wang
    Ping Cao
    Acta Geotechnica, 2023, 18 : 4375 - 4388
  • [34] In situ long-term improvement of large-scale lacustrine soft soil using laboratory and field data: a case study from a copper mine in China
    Fan, Wenchen
    Jiang, Xueliang
    Wang, Xingxing
    Cao, Ping
    ACTA GEOTECHNICA, 2023, 18 (08) : 4375 - 4388