Treatment vault shielding for a flattening filter-free medical linear accelerator

被引:29
|
作者
Kry, Stephen F. [1 ]
Howell, Rebecca M. [1 ]
Polf, Jerimy [1 ]
Mohan, Radhe [1 ]
Vassiliev, Oleg N. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 05期
关键词
UNFLATTENED PHOTON BEAMS; DOSIMETRIC PROPERTIES; MONTE-CARLO;
D O I
10.1088/0031-9155/54/5/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy ( 6 MV) linac and a dual-energy ( 6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m(3) less concrete to shield the single-energy linac and 36 m3 less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.
引用
收藏
页码:1265 / 1273
页数:9
相关论文
共 50 条
  • [31] Feasibility of portal dosimetry for flattening filter-free radiotherapy
    Chuter, Robert W.
    Rixham, Philip A.
    Weston, Steve J.
    Cosgrove, Vivian P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 112 - 120
  • [32] Flattening Filter-free Beams for SBRT: Advantages and Risks
    Verbakel, W.
    Ong, C.
    Senan, S.
    Cuijpers, J. P.
    Slotman, B. J.
    Dahele, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S826 - S827
  • [33] A study on the effect of using a flattening filter in a medical linear accelerator on the dose distribution
    Kim, Young-Jae
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Lim, Chang-Seon
    Jeong, Cheon-Soo
    Seo, Yoon-Jeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (06) : 917 - 922
  • [34] A study on the effect of using a flattening filter in a medical linear accelerator on the dose distribution
    Young-Jae Kim
    Kyung-Rae Dong
    Woon-Kwan Chung
    Chang-Seon Lim
    Cheon-Soo Jeong
    Yoon-Jeong Seo
    Journal of the Korean Physical Society, 2014, 64 : 917 - 922
  • [35] Commissioning of Flattening Filter Free Varian 600C Linear Accelerator
    Stathakis, S.
    Gutierrez, A.
    Rassiah-Szegedi, P.
    Mavroidis, P.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06) : 2781 - +
  • [36] Breast Tangential Treatment Plan Using Flattening Filter-free Beams: A Planning Study
    Xie, J.
    Cao, J.
    Chen, W.
    Cui, Y.
    Galvin, J.
    Yu, Y.
    Xiao, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S867 - S867
  • [37] Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment
    Alfishawy, Mahmoud Mohamed
    Kany, Amr Ismail
    Elshahat, Khaled Mohamed
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 455 - 464
  • [38] Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening filter-free 7 MV beam line
    Sadrollahi, Alemeh
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    Dzierma, Yvonne
    PLOS ONE, 2019, 14 (01):
  • [39] Improved Treatment Efficiency With Flattening Filter-free Mode and Implications for Common Clinical Scenarios
    Thomas, E.
    Popple, R. A.
    Prendergast, B. M.
    Dobelbower, M. C.
    Fiveash, J. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S860 - S860
  • [40] Clinically relevant investigation of flattening filter-free skin dose
    Guy, Christopher L.
    Karki, Kishor
    Sharma, Manju
    Kim, Siyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 140 - 148