Two Alternative Surgical Techniques for Enhancing Primary Implant Stability in the Posterior Maxilla: A Clinical Study Including Bone Density, Insertion Torque, and Resonance Frequency Analysis Data

被引:127
|
作者
Turkyilmaz, Ilser [2 ]
Aksoy, Utku [1 ]
McGlumphy, Edwin A. [2 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Periodontol, Ankara, Turkey
[2] Ohio State Univ, Coll Dent, Dept Restorat & Prosthet Dent, Columbus, OH 43218 USA
关键词
bone density; computerized tomography; Hounsfield unit; implant; implant stability; insertion torque; resonance frequency analysis;
D O I
10.1111/j.1708-8208.2008.00084.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The primary stability of dental implants associated with resistance to micromotion during healing is affected by surgical technique and implant design, which are important especially in the soft bone, where implant failures are more likely. Purposes: This study was designed to compare the parameters associated with implant insertion using two different methods of enhancing implant primary stability and to identify any relationship between these parameters at implant insertion. Materials and Methods: A total of 60 implants were placed in the maxillary posterior regions of 22 patients. The bone densities at the implant sites were recorded using a computerized tomography machine in Hounsfield unit (HU). The maximum insertion torque data were recorded with the Osseocare (TM) (Nobel Biocare AB, Goteborg, Sweden) equipment, while resonance frequency analysis (RFA) measurements were taken using an Osstell (TM) (Integration Diagnostics AB, Goteborg, Sweden) machine at implant surgery. Comparisons including HU, Ncm, and implant stability quotient were made between two control groups (C1 and C2), and corresponding four test groups (T1-T4) using thinner drills to enhance primary implant stability. Results: Two implants were lost, meaning an overall implant survival rate of 96.6% after 3 +/- 1 years. When compared to control groups, significantly higher mean maximum insertion torque and RFA values were found for corresponding test groups. In addition, strong correlations were observed between the bone density and insertion torque, and implant stability values at implant placement. Conclusion: The results of this study suggest that using thinner drills for implant placement in the maxillary posterior region where bone quality is poor may improve the primary implant stability, which helps clinicians to obtain higher implant survival rates.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 25 条
  • [21] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study
    Jacek Matys
    Rafał Flieger
    Gianluca Tenore
    Kinga Grzech-Leśniak
    Umberto Romeo
    Marzena Dominiak
    Lasers in Medical Science, 2018, 33 : 489 - 495
  • [22] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study
    Matys, Jacek
    Flieger, Rafa
    Tenore, Gianluca
    Grzech-Lesniak, Kinga
    Romeo, Umberto
    Dominiak, Marzena
    LASERS IN MEDICAL SCIENCE, 2018, 33 (03) : 489 - 495
  • [23] A comparison of implant stability quotients measured using magnetic resonance frequency analysis from two directions: a prospective clinical study during the initial healing period
    Park, Jong-Chul
    Kim, Hyun-Duck
    Kim, Soung-Min
    Kim, Myung-Jin
    Lee, Jong-Ho
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (06) : 591 - 597
  • [24] Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT
    Nakashima, Daisuke
    Ishii, Ken
    Nishiwaki, Yuji
    Kawana, Hiromasa
    Jinzaki, Masahiro
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01) : 1
  • [25] Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT
    Daisuke Nakashima
    Ken Ishii
    Yuji Nishiwaki
    Hiromasa Kawana
    Masahiro Jinzaki
    Morio Matsumoto
    Masaya Nakamura
    Takeo Nagura
    European Radiology Experimental, 3