Autologous cultured chondrocytes:: Adverse events reported to the united states food and drug administration

被引:147
|
作者
Wood, JJ
Malek, MA
Frassica, FJ
Power, JA
Mohan, AK
Bloom, ET
Braun, MM
Coté, TR
机构
[1] Ctr Dis Control, Atlanta, GA 30329 USA
[2] US FDA, Ctr Biol Evaluat & Res, Rockville, MD 20852 USA
[3] Johns Hopkins Univ, Baltimore, MD 21287 USA
来源
关键词
D O I
10.2106/JBJS.E.00103
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Carticel is an autologous cultured chondrocyte product that has been approved by the United States Food and Drug Administration for the repair of symptomatic cartilaginous defects of the femoral condyle that are caused by acute or repetitive trauma in patients who have been previously managed with arthroscopy or other surgical procedures. The present report describes the adverse events following Carticel implantation as reported to the Food and Drug Administration from 1996 to 2003. Methods: We reviewed adverse event reports that had been submitted to the Food and Drug Administration's Med-Watch system for information on demographic characteristics, adverse events, and surgical revisions. Adverse events were categorized into sixteen non-mutually exclusive groups. Five categories were used to classify reoperations. Food and Drug Administration regulations require manufacturers to report adverse events; however, reporting by clinicians and others is voluntary. Therefore, adverse event reporting is likely to underestimate the number of event occurrences. Adverse events may be either causally or coincidentally related to the product. Results: A total of 497 adverse events among 294 patients receiving Carticel were reported. The median interval from Carticel implantation to the diagnosis of an adverse event was 240 days (range, one to 2105 days). The median age of the patients was thirty-eight years, and 63% of the patients were male. Of the 270 events for which the anatomic site was noted, 258 (96%) involved the femoral condyles. More than one adverse event was reported for 135 patients (46%). The most commonly reported events were graft failure (seventy-three patients; 25%), delamination (sixty-five patients; 22%), and tissue hypertrophy (fifty-two patients; 18%). In addition, eighteen surgical site infections were reported, including eleven joint and seven soft-tissue infections. Surgical revision subsequent to Carticel implantation was mentioned in the records for 273 patients (93%). The reasons for the 389 revision procedures included graft-related problems (187 procedures; 48.1%), periarticular soft-tissue problems (ninety-seven procedures; 24.9%), and intra-articular problems (sixty-three procedures; 16.2%). Eight patients had a total knee replacement. Based on the manufacturer's reported distribution of 7500 Carticel lots between 1995 and 2002, 285 patients (3.8%) had an adverse event that was reported to the Food and Drug Administration. Conclusions: The most common adverse events reported in association with the Carticel technique involved graft failure, delamination, and tissue hypertrophy.
引用
收藏
页码:503 / 507
页数:5
相关论文
共 50 条
  • [31] Serious Adverse Drug Reactions Related to Boceprevir: Analysis of Food and Drug Administration Reported Events
    Love, Bryan L.
    Garg, Vishvas
    Arabyat, Rasha
    Raisch, Dennis W.
    Bennett, Charles L.
    HEPATOLOGY, 2013, 58 : 228A - 228A
  • [32] Spontaneous Reporting on Adverse Events by Consumers in the United States: An Analysis of the Food and Drug Administration Adverse Event Reporting System Database
    Toki T.
    Ono S.
    Drugs - Real World Outcomes, 2018, 5 (2) : 117 - 128
  • [33] Adverse drug events of denosumab: Data-mining based on the United States Food and Drug Administration Adverse Event Reporting System database
    Liu, Shaohua
    Jiang, Wangyan
    Guo, Jieru
    Zhou, Xinrong
    Liu, Zhelong
    JOURNAL OF RESEARCH IN PHARMACY, 2024, 28 (04): : 1220 - 1230
  • [34] Adverse Events Related to Cartiva Hemiarthroplasty of First Metatarsal: An Analysis of Reports to the United States Food and Drug Administration
    Metikala, Sreenivasulu
    Mahmoud, Karim
    O'Connor, Kathryn M.
    Chao, Wen
    Wapner, Keith L.
    Farber, Daniel C.
    FOOT & ANKLE SPECIALIST, 2022, 15 (02) : 113 - 118
  • [35] Adverse events related to total ankle replacement devices: an analysis of reports to the United States Food and Drug Administration
    Karim Mahmoud
    Sreenivasulu Metikala
    Kathryn M. O’Connor
    Daniel C. Farber
    International Orthopaedics, 2021, 45 : 2307 - 2312
  • [36] Adverse events related to total ankle replacement devices: an analysis of reports to the United States Food and Drug Administration
    Mahmoud, Karim
    Metikala, Sreenivasulu
    O'Connor, Kathryn M.
    Farber, Daniel C.
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (09) : 2307 - 2312
  • [37] Adverse Events Reported to the US Food and Drug Administration for Cosmetics and Personal Care Products
    Kwa, Michael
    Welty, Leah J.
    Xu, Shuai
    JAMA INTERNAL MEDICINE, 2017, 177 (08) : 1202 - 1204
  • [38] Surgical stapler-associated fatalities and adverse events reported to the food and drug administration
    Brown, SL
    Woo, EK
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2004, 199 (03) : 374 - 381
  • [39] Local anesthetic infusion pump systems adverse events reported to the Food and Drug Administration
    Brown, SL
    Morrison, AE
    ANESTHESIOLOGY, 2004, 100 (05) : 1305 - 1306
  • [40] Characterizing Adverse Events in Using the Spiration Valve System as Reported by the Food and Drug Administration
    Magsino, E.
    Asnaashari, P.
    Meruvia, J.
    Tanner, T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209