Direct analysis of particulate matter (PM10) for the determination of Be, Cd and Pb using high resolution-continuum source electrothermal atomic absorption spectrometry: Assessment of the potential correlation between analyte content and meteorological parameters

被引:12
|
作者
Almeida, Tarcisio S. [1 ]
Brancher, Marlon [2 ]
Lisboa, Henrique de Melo [2 ]
Franco, Davide [2 ]
Maranhao, Tatiane A. [1 ]
Borges, Daniel L. G. [1 ]
机构
[1] Univ Fed Santa Catarina, Chem Dept, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Sanit & Environm Engn, Lab Air Qual Control LCQAr, BR-88040900 Florianopolis, SC, Brazil
关键词
Direct solid analysis; Atmospheric particulate matter; Trace elements; PM10; GLASS-FIBER FILTERS; SEQUENTIAL DETERMINATION; HEAVY-METALS; AMBIENT AIR; LEAD; CADMIUM; SAMPLES; COPPER; BERYLLIUM; ATOMIZATION;
D O I
10.1016/j.sab.2020.105951
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Atmospheric particulate matter (APM) monitoring is a fundamental tool for air pollution management and control. However, the limited amount of an APM sample that is typically available upon collection using specific devices may be a limiting factor to promote reliable chemical analysis. Direct solid analysis is thus a cost-effective alternative to be applied for this purpose, since it simplifies the handling of samples, combining faster analysis to maximum detectability with minimum sample consumption. This study presents the development of methods for the determination of beryllium, cadmium and lead in inhalable particulate matter (PM10) using direct solid analysis and high-resolution continuum source electrothermal atomic absorption spectrometry. The temperature program and the use of chemical modifiers were optimized for each individual analyte. Zirconium was used as a permanent modifier for the determination of Be, whereas Pd and Mg were co-injected as chemical modifiers for the determination of Cd and Pb. The potential interferences and calibration strategies were also evaluated. Under optimized conditions, calibration against aqueous standards was proven feasible and detection limits of 0.001, 0.001 and 0.004 ng m(-3) for Be, Cd and Pb, respectively, were achieved. The methods were applied to the determination of the referred analytes in 28 samples of PM10 collected at an urban site in the city of Florianopolis, in the State of Santa Catarina, Brazil. Chemometric treatment of data considering analyte content in addition to meteorological parameters (accumulated rainfall, sunlight incidence and wind speed) showed a detectable correlation between these parameters. Samples could be statistically differentiated based on separate loadings for Cd and Pb, which was opposite to Be, for instance. Hence, there is the possibility to correlate these parameters in order to establish a relationship between the origin of the elements in the PM10 samples and the impact of meteorological conditions on their distribution in solid atmospheric particles.
引用
收藏
页数:9
相关论文
共 30 条
  • [21] Determination of Cu in blood via direct analysis of dried blood spots using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Garcia-Poyo, M. Carmen
    Pecheyran, Christophe
    Rello, Luis
    Garcia-Gonzalez, Elena
    Alonso Rodriguez, Sharay
    Nakadi, Flavio V.
    Aramendia, Maite
    Resano, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (08) : 1666 - 1677
  • [22] Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry-Determination of antimony in sediment reference materials using direct solid sampling
    Araujo, Rennan G. O.
    Welz, Bernhard
    Vignola, Fabiola
    Becker-Ross, Helmut
    TALANTA, 2009, 80 (02) : 846 - 852
  • [23] Simultaneous Determination of Cd and Fe in Beans and Soil of Different Regions of Brazil Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry and Direct Solid Sampling
    dos Santos, Lisia M. G.
    Welz, Bernhard
    Araujo, Rennan G. O.
    Jacob, Silvana do C.
    Vale, Maria Goreti R.
    Martens, Andreas
    Gonzaga Martens, Irland B.
    Becker-Ross, Helmut
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (21) : 10089 - 10094
  • [24] Development of analytical methods for the determination of copper and manganese in infant formula using high resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Gamela, Raimundo R.
    Duarte, Alvaro T.
    Barrera, Eliana G.
    Welz, Bernhard
    Dessuy, Morgana B.
    da Silva, Marcia Messias
    Vale, Maria Goreti R.
    ANALYTICAL METHODS, 2017, 9 (15) : 2321 - 2327
  • [25] Determination of cadmium, chromium and copper in vegetables of the Solanaceae family using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Pozzatti, Marianna
    Borges, Aline R.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Welz, Bernhard
    ANALYTICAL METHODS, 2017, 9 (02) : 329 - 337
  • [26] Simultaneous determination of nickel and iron in vegetables of Solanaceae family using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Pozzatti, Marianna
    Nakadi, Flavio V.
    Vale, Maria Goreti R.
    Welz, Bernhard
    MICROCHEMICAL JOURNAL, 2017, 133 : 162 - 167
  • [27] Method development for the determination of Cd, Cu, Ni and Pb in PM2.5 particles sampled in industrial and urban areas of Greater Cairo, Egypt, using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Shaltout, Abdallah A.
    Boman, Johan
    Welz, Bernhard
    Castilho, Ivan N. B.
    Al Ashkar, Emad A.
    Gaita, S. M.
    MICROCHEMICAL JOURNAL, 2014, 113 : 4 - 9
  • [28] Determination of palladium, platinum and rhodium in used automobile catalysts and active pharmaceutical ingredients using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Resano, Martin
    del Rosario Florez, Maria
    Queralt, Ignasi
    Margui, Eva
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 105 : 38 - 46
  • [29] Determination of Cd and Cr in tannin samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample sequential analysis (HR-CS SS-GF AAS)
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Vale, Maria Goreti R.
    ANALYTICAL METHODS, 2015, 7 (09) : 3735 - 3741
  • [30] Direct solid analysis for the determination of Mn, Ni, Rb and Sr in powdered stimulant plants using high-resolution continuum source atomic absorption spectrometry followed by chemometric classification based on elemental composition, polyphenol content and antioxidant activity
    de Gois, Jefferson S.
    Almeida, Tarcisio S.
    de Andrade, Rodolpho M.
    Toaldo, Isabela M.
    Bordignon-Luiz, Marilde T.
    Borges, Daniel L. G.
    MICROCHEMICAL JOURNAL, 2016, 124 : 283 - 289