Reliable Estimation of Respiration Rate Using UWB Impulse Radar

被引:0
|
作者
Kang, Jae-Mo [1 ]
Lim, Dong-Woo [1 ]
Lee, Jae-Hwan [1 ]
In, Changdon [1 ]
Kim, Hyung-Myung [1 ]
Woo, Sung-Chul [2 ]
Kim, Cheonsoo [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
[2] Elect & Telecommun Res Inst, SoC Res Dept, Taejon, South Korea
关键词
UWB impulse radar; energy detector; respiration-rate; high range resolution; noise subspace method;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a procedure for reliable estimation of the respiration rate using UWB impulse radar. We initially extract the respiratory signal using the energy detector to reduce the effect of the multipath impulse response of the human body. Then, the noise subspace methods are applied to estimate the respiration-rate more accurately. The experimental results show that the proposed method is more reliable than the conventional method.
引用
收藏
页码:997 / 999
页数:3
相关论文
共 50 条
  • [21] A Joint Localization and Breathing Rate Estimation of Static Persons Using UWB Radar
    Kocur, Dusan
    Novak, Daniel
    Demcak, Jakub
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 1728 - 1733
  • [22] Noncontact Heartbeat Detection Using UWB Impulse Doppler Radar
    Ren, Lingyun
    Fathy, Aly E.
    2015 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM) PROCEEDINGS, 2015, : 221 - 221
  • [23] Functional neuroimaging using UWB impulse radar: A feasibility study
    Lauteslager, Timo
    Nicolaou, Nicoletta
    Lande, Tor Sverre
    Constandinou, Timothy
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 406 - 409
  • [24] Measuring human body impulse response using UWB radar
    Tan, AEC
    Chia, MYW
    ELECTRONICS LETTERS, 2005, 41 (21) : 1193 - 1194
  • [25] Noncontact Heartbeat Detection using UWB Impulse Doppler Radar
    Ren, Lingyun
    Koo, Yun Seo
    Wang, Yazhou
    Fathy, Aly E.
    2015 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2015, : 14 - 16
  • [26] Thresholded samplers for UWB impulse radar
    Hjortland, Hakon A.
    Wisland, Dag T.
    Lande, Tor Sverre
    Limbodal, Claus
    Meisal, Kjetil
    2007 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, 2007, : 1210 - +
  • [27] A UWB impulse subsurface imaging radar
    Lei, WT
    Su, Y
    IEEE 2005 International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications Proceedings, Vols 1 and 2, 2005, : 1356 - 1360
  • [28] Estimation of Breathing Frequency and Heart Rate by Biometric UWB Radar
    Kocur, Dusan
    Svecova, Maria
    Demcak, Jakub
    2018 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2018, : 2570 - 2576
  • [29] Convolutional neural network for people counting using UWB impulse radar
    Pham, C-T
    Luong, V. S.
    Nguyen, D-K
    Vu, H. H. T.
    Le, M.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08):
  • [30] Performance analysis of UWB impulse radar using parallel IPCP receiver
    Hatano, H
    Okada, H
    Yamazato, T
    Katayama, M
    1ST INTERNATIONAL SYMPOSIUM ON WIRELESS COMMUNICATION SYSTEMS 2004, PROCEEDINGS, 2004, : 115 - 119