摘要
Background: Quantitative shear wave elastography (SWE) has been developed and utilized to aid in the differentiation between benign and malignant breast lesions based on their stiffness. Objectives: The purpose of this study was to evaluate the clinical effects of the additional use of SWE to conventional ultrasound (US) according to the maximum (Emax) and mean (Emean) elasticitiy values. Patients and Methods: A total 115 patients with 133 lesions were assessed using conventional US and SWE. All patients underwent US-guided core needle biopsy or surgery, and the pathological results were used as reference standards. We compared the diagnostic values including sensitivities, specificities, positive predictive values (PPVs) and negative predictive values (NPVs) and accuracies of conventional US and SWE according to the E-max and E-mean values. Next, we obtained the optimal E-max and E-mean cutoff values for SWE. Using these cutoff values, we analyzed the clinical effects of the additional use of SWE to conventional US based on the corrected results. Results: Of the 133 breast lesions, 32 were malignant and 101 were benign. In the differentiation of benign and malignant lesions, conventional US resulted in sensitivity of 100 %, specificity of 43.0 %, PPV of 57.1 %, NPV of 36.7 %, and accuracy of 100 %. Regarding SWE, the sensitivity, specificity, PPV, NPV, and accuracy values based on E-max were 84.4 %, 89.1 %, 71.1 %, 94.7 %, and 88.0 %, respectively, and the corresponding values based on E-mean were 84.8 %, 93.0 %, 91.0 %, 80.0 %, and 94.9 %, respectively. The optimal E-max and E-mean cutoff values were 81.3 and 60.7 kPa, respectively. However, there was no significant difference between E-max and E-mean. The corrected results related to the additional use of SWE to conventional US indicated 97.0 % sensitivity, 93.0 % specificity, 82.1 % PPV, 98.9 % NPV, and 94.0 % accuracy (P < 0.0001). Conclusion: The additional use of SWE to conventional US resulted in marked improvements in specificity, PPV, and accuracy and slight diminutions in sensitivity and NPV for the differentiation benign and malignant breast lesions. Both E-max and E-mean were effective diagnostic parameters, and there was no significant difference between these two parameters.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Clinical application of qualitative assessment for breast masses in shear-wave elastography
    Gweon, Hye Mi
    Youk, Ji Hyun
    Son, Eun Ju
    Kim, Jeong-Ah
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E680 - E685
  • [2] Shear wave elastography for breast masses is highly reproducible
    Cosgrove, David O.
    Berg, Wendie A.
    Dore, Caroline J.
    Skyba, Danny M.
    Henry, Jean-Pierre
    Gay, Joel
    Cohen-Bacrie, Claude
    EUROPEAN RADIOLOGY, 2012, 22 (05) : 1023 - 1032
  • [3] Shear wave elastography for breast masses is highly reproducible
    David O. Cosgrove
    Wendie A. Berg
    Caroline J Doré
    Danny M. Skyba
    Jean-Pierre Henry
    Joel Gay
    Claude Cohen-Bacrie
    European Radiology, 2012, 22 : 1023 - 1032
  • [4] Breast Shear Wave Elastography in Clinical Practice
    Evans, Andrew
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 119 - 121
  • [5] Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis
    Zhou, Bang-Guo
    Wang, Dan
    Ren, Wei-Wei
    Li, Xiao-Long
    He, Ya-Ping
    Liu, Bo-Ji
    Wang, Qiao
    Chen, Shi-Gao
    Alizad, Azra
    Xu, Hui-Xiong
    SCIENTIFIC REPORTS, 2017, 7
  • [6] Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis
    Bang-Guo Zhou
    Dan Wang
    Wei-Wei Ren
    Xiao-Long Li
    Ya-Ping He
    Bo-Ji Liu
    Qiao Wang
    Shi-Gao Chen
    Azra Alizad
    Hui-Xiong Xu
    Scientific Reports, 7
  • [7] Does Shear Wave Elastography Score Over Strain Elastography in Breast Masses or Vice Versa?
    Singla, Veenu
    Prakash, Aparna
    Prabhakar, Nidhi
    Singh, Tulika
    Bal, Amanjit
    Singh, Gurpreet
    Khandelwal, Niranjan
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2020, 49 (02) : 96 - 101
  • [8] Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases
    Chang, Jung Min
    Moon, Woo Kyung
    Cho, Nariya
    Yi, Ann
    Koo, Hye Ryoung
    Han, Wonsik
    Noh, Dong-Young
    Moon, Hyeong-Gon
    Kim, Seung Ja
    BREAST CANCER RESEARCH AND TREATMENT, 2011, 129 (01) : 89 - 97
  • [9] Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases
    Jung Min Chang
    Woo Kyung Moon
    Nariya Cho
    Ann Yi
    Hye Ryoung Koo
    Wonsik Han
    Dong-Young Noh
    Hyeong-Gon Moon
    Seung Ja Kim
    Breast Cancer Research and Treatment, 2011, 129 : 89 - 97
  • [10] Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
    Evans, Andrew
    Whelehan, Patsy
    Thomson, Kim
    McLean, Denis
    Brauer, Katrin
    Purdie, Colin
    Jordan, Lee
    Baker, Lee
    Thompson, Alastair
    BREAST CANCER RESEARCH, 2010, 12 (06)